Abstract
BACKGROUND:
The rupture of syndesmotic ligaments is treated with a screw fixation as the gold standard. An alternative is the stabilization with a TightRope
OBJECTIVE:
Is there a difference in pressure inside the distal tibiofibular joint between a screw fixation and a TightRope
METHODS:
This biomechanical study aimed to investigate the differences in fixation of the injured syndesmotic ligaments by using a fixation with one quadricortical screw versus singular TightRope
RESULTS:
The mean of the pressure across the distal tibiofibular joint from the start of the insertion of the fixation device to the complete fixation was 0.05 Pascal for the TightRope
CONCLUSIONS:
The screw fixation is stronger and provides a larger surface contact area, which leads us to the conclusion that it provides a better stability in the joint. While previous clinical studies did not show significant clinical difference between the two methods of fixation, the biomechanical construct varied. Long term clinical studies are required to establish whether this biomechanical distinction will contribute to various clinical outcomes.