Abstract
OBJECTIVE:
To compare the dosimetric and efficiency differences for left-sided breast cancer radiotherapy after breast-conserving surgery among three different planning techniques: double-arc volumetric-modulate arc therapy (VMAT), step-shoot intensity-modulated radiotherapy (sIMRT) and three-dimensional conformal radiation therapy (3D-CRT).
MATERIALS AND METHODS:
A total of 17 female patients with left-sided breast cancer who underwent breast-conserving surgery were selected; the prescription doses were 50 Gy in 25 fractions. For every patient VMAT, sIMRT and 3D-CRT plans were generated within the Monaco treatment planning system for an Axesse™ accelerator equipped with the Agility MLC. The Conformity Index (CI), the Homogeneity Index (HI), the dose volume histogram (DVH) parameters for the organs at risk and the delivery efficiency were evaluated.
RESULTS:
The VMAT plans showed on average higher CI of PTV (0.77
CONCLUSION:
For left-sided breast cancer radiotherapy after breast-conserving surgery, the VMAT plans had a better CI than the sIMRT and 3D-CRT plans. The VMAT and the sIMRT plans had better HI than the 3D-CRT plans, but no significant difference was observed between VMAT and sIMRT.
Keywords
Get full access to this article