Abstract
At RIKEN, a transportable accelerator-driven compact neutron source (RANS-III) is under development for an on-site nondestructive inspection of the degradation of old concrete and reinforcing steel. RANS-III consists of an ion source, a low-energy beam transport, a radio frequency quadrupole linear accelerator (RFQ linac), a radio frequency (RF) system, a high-energy beam transport, a target station and a neutron measurement system. Because the inner diameter of the RFQ linac is inversely proportional to the resonance frequency, the resonance frequency of the RANS-III RFQ linac in this study was chosen to be 500 MHz, which is 2.5 times that of the RANS-II RFQ linac. Therefore, the inner diameter and weight of the RANS-III RFQ linac were reduced to approximately half and one third, respectively, of those of the RANS-II RFQ linac. The RANS-III RFQ linac was designed to accelerate a proton beam with a 10 mA peak current and 100 μA average beam current from 30 keV to 2.49 MeV (Journal of Disaster Research