This paper enhanced the integration-type E&S model and the dynamic E&S model for integrating the impact of DC-biased field and eddy current on vector magnetic properties of electrical steel sheet.
B
and
H
of electrical steel sheet are measured under DC-biased and rotating fields. Based on the measured results, the databases of reluctivity and hysteresis coefficients of both the enhanced integration-type E&S model and the improved dynamic E&S model are established for predicting
H
waveform under any given operating condition. By comparing the
H
waveform calculated by the enhanced integration-type E&S model and the improved dynamic E&S model with the experimental
H
waveform, it is found that both two models have good reliability and the improved dynamic E&S model has slightly better accuracy than the enhanced integration-type E&S model.