BACKGROUND: Deep vein thrombosis and the risk of pulmonary embolism are significant causes of morbidity and mortality. Much remains unclear, however, about the mechanisms by which a venous thrombus initiates, progresses, or resolves. In particular, there is a pressing need to characterize the evolving mechanical properties of a venous thrombus for its mechanical integrity is fundamental to many disease sequelae.
OBJECTIVE: The primary goal of the present study was to initiate a correlation between evolving histological changes and biomechanical properties of venous thrombus.
METHODS: We employed an inferior vena cava ligation model in mice to obtain cylindrical samples of thrombus that were well suited for mechanical testing and that could be explanted at multiple times following surgery. Using uniaxial micro-mechanical testing, we collected stress–stretch data that were then fit with a microstructurally-inspired material model before submitting the samples to immunohistological examination.
RESULTS: We found that venous thrombus underwent a radially inward directed replacement of fibrin with collagen between 2 weeks and 4 weeks of development, which was accompanied by the infiltration of inflammatory and mesenchymal cells. These histological changes correlated with a marked increase in material stiffness.
CONCLUSIONS: We demonstrated that 2 to 4 week old venous thrombus undergoes drastic remodeling from a fibrin-dominated mesh to a collagen-dominated microstructure and that these changes are accompanied by dramatic changes in biomechanical behavior.
KyrlePAEichingerS. Deep vein thrombosis. Lancet. 2005;365:1163–1174.
2.
WeinmannEESalzmanEW. Deep-vein thrombosis. N Engl J Med. 1994;331:1630–1641.
3.
RobertsWWLorandLMackrosLF. Viscoelastic properties of fibrin clots. Biorheology. 1973;10:29–42.
4.
RobertsWWKramerORosserRWNestlerFHMFerryJD. Rheology of fibrin clots. I. Biophys Chem. 1974;1:152–160.
5.
EmelianovSYChenXO’DonnellMKnippBMyersDWakefieldTW, et al. Triplex ultrasound: Elasticity imaging to age deep venous thrombosis. Ultrasound Med Biol. 2002;28:757–767.
6.
KarsajIHumphreyJD. A mathematical model of evolving mechanical properties of intraluminal thrombus. Biorheology. 2009;46:509–527.
7.
FineschiVTurillazziENeriMPomaraCRiezzoI. Histological age determination of venous thrombosis: A neglected forensic task in fatal pulmonary thrombo-embolism. Forensic Sci Int. 2009;186:22–28.
8.
NosakaMIshidaYKimuraAKondoT. Time-dependent organic changes of intravenous thrombi in stasis-induced deep vein thrombosis model and its application to thrombus age determination. Forensic Sci Int. 2010;195:143–147.
9.
SchrieflAJCollinsMJPierceDMHolzapfelGANiklasonLEHumphreyJD. Remodeling of intramural thrombus and collagen in an Ang-II infusion ApoE-/- model of dissecting aortic aneurysms. Thromb Res. 2012;130:e139–e146.
10.
KuDNFlanneryCJ. Development of a flow-through system to create occluding thrombus. Biorheology. 2007;44:273–284.
11.
DeatrickKBEliasonJLLynchEMMooreAJDewyerNAVarmaMR, et al. Vein wall remodeling after deep vein thrombosis involves matrix metalloproteinases and late fibrosis in a mouse model. J Vasc Surg. 2005;42:140–148.
12.
DiazJAObiATMyersDDWrobleskiSKHenkePKMackmanN, et al. Critical review of mouse models of venous thrombosis. Arterioscler Thromb Vasc Biol. 2012;32:556–562.
13.
GleasonRLGraySPWilsonEHumphreyJD. A multiaxial computer-controlled organ culture and biomechanical device for mouse carotid arteries. J Biomech Eng. 2004;126:787–795.
14.
HurschlerCLoitz-RamageBVanderbyR. A structurally based stress–stretch relationship for tendon and ligament. J Biomech Eng. 1997;119:392–399.
15.
LeeDYukiIMurayamaYChiangANishimuraIVintersHV, et al. Thrombus organization and healing in the swine experimental aneurysm model. Part I. A histological and molecular analysis. J Neurosurg. 2007;107:94–108.
16.
TomasekJJGabbianiGHinzBChaponnierCBrownRA. Myofibroblasts and mechano-regulation of connective tissue remodelling. Nat Rev Mol Cell Biol. 2002;3:349–363.
17.
HinzB. The myofibroblast: Paradigm for a mechanically active cell. J Biomech. 2010;43:146–155.
18.
TongJCohnertTRegitnigPHolzapfelGA. Effects of age on the elastic properties of the intraluminal thrombus and the thrombus-covered wall in abdominal aortic aneurysms: Biaxial extension behaviour and material modelling. Eur J Vasc Endovasc Surg. 2011;42:207–219.
19.
BeattyMFKrishnaswamyS. A theory of stress-softening in incompressible isotropic materials. J Mech Phys Solids. 2000;48:1931–1965.
20.
HumphreyJD. Cardiovascular solid mechanics: Cells, tissues, and organs. New York: Springer; 2002.
21.
Van DamEADamsSDPetersGWMRuttenMCMSchurinkGWHButhJ, et al. Determination of linear viscoelastic behavior of abdominal aortic aneurysm thrombus. Biorheology. 2006;43:695–707.
22.
MünsterSJawerthLMLeslieBAWeitzJIFabryBWeitzDA. Strain history dependence of the nonlinear stress response of fibrin and collagen networks. Proc Natl Acad Sci. 2013;110:12197–12202.
23.
KamadaHTsubotaKNakamuraMWadaSIshikawaTYamaguchiT. Computational study on effect of stenosis on primary thrombus formation. Biorheology. 2011;48:99–114.
24.
Von BrühlMLStarkKSteinhartAChandraratneSKonradILorenzM, et al. Monocytes, neutrophils, and platelets cooperate to initiate and propagate venous thrombosis in mice in vivo. J Exp Med. 2012;209:819–835.