BACKGROUND: Blood flow in stenotic vessels strongly influences the progression of vascular diseases. Plaques in stenotic blood vessels vary in stiffness, which influences plaque behavior and deformation by pressure and flow. Concurrent changes in plaque geometry can, in turn, affect blood flow conditions. Thus, simultaneous studies of blood flow and plaque deformation are needed to fully understand these interactions.
OBJECTIVES: This study aims to identify the change of flow conditions attendant to plaque deformation in a model stenotic vessel.
METHODS: Three plaques of differing stiffness were constructed on a vessel wall using poly (vinyl alcohol) hydrogels (PVA-H) with defined stiffness to facilitate simultaneous observations of blood flow and plaque deformation. Flow patterns were observed using particle image velocimetry (PIV).
RESULTS: Decreases in Reynolds number (Re) with increased plaque deformation suggest that velocity decrease is more critical to establishment of the flow pattern than expansion of the model lumen. Upon exiting the stenosis, the location of the flow reattachment point, shifted further downstream in all models as plaque stiffness decreased and depended on the increase in upstream pressure.
CONCLUSIONS: These results suggest that in addition to luminal area, plaque stiffness should be considered as a measure of the severity of the pathology.
GolledgeJGreenhalghRMDaviesAH. The symptomatic carotid plaque. Stroke. 2000;31:774–781.
2.
YamagishiTKatoMKoiwaY, et al. Evaluation of plaque stabilization by fluvastatin with carotid intima-medial elasticity measured by a transcutaneous ultrasonic-based tissue characterization system. J Atherosclero Thromb. 2009;16:662–673.
3.
ShiHRMitchellCCMcCormickM, et al. Preliminary in vivo atherosclerotic carotid plaque characterization using the accumulated axial strain and relative lateral shift strain indices. Phys Med Bio. 2008;53:6377–6394.
4.
KumeSHamaSYamaneK, et al. Vulnerable carotid arterial plaque causing repeated ischemic stroke can be detected with B-mode ultrasonography as a mobile component: Jellyfish sign. Neuros Review. 2010;33:419–430.
5.
GriffithMDLewekeTThompsonMC, et al. Steady inlet flow in stenotic geometries: Convective and absolute instabilities. J Fluid Mech. 2008;616:111–133.
6.
HayaseHTokunagaKNakayamaT, et al. Computational fluid dynamics of carotid arteries after carotid endarterectomy or carotid artery stenting based on postoperative patient-specific CT angiography and ultrasound flow data. Neurosurgery. 2011;68:1096–1101.
7.
MoayeriMSZendehbudiGR. Effects of elastic property of the wall on flow characteristics through arterial stenoses. J Biomechanics. 2003;36:525–535.
8.
JiJToubaruSKobayashiS, et al. Flow and deformation in a multi-component arterial stenosis model. J Biomech Sci Eng. 2011;6:79–88.
9.
ShimizuYShidaSFunamotoK, et al. Influence of plaque stiffness on change of blood vessel geometry leading hemodynamical changes in PVA-H stenosis model. In: Proceedings of ASME 2012. 2012. doi:10.1115/IMECE2012-87073.
10.
ShimizuYJavadzadeganAHayaseT, et al. Flow observations in elastic stenosis biomodel with comparison to rigid-like model. Tech Health Care. 2013;21:305–314.
11.
ShidaSKosukegawaHOhtaM. Development of a methodology for adaptation of refractive index under controlling kinematic viscosity for PIV. In: Proceedings of ASME 2011. 2011. doi:10.1115/IMECE2011-64388.
12.
OhtaMHandaAIwataH, et al. Poly-vinyl alcohol hydrogel vascular models for in vitro aneurysm simulations: The key to low friction surfaces. Tech Health Care. 2004;12:225–233.
13.
YuCHKosukegawaHMamadaK, et al. Development of an in vitro tracking system with poly (vinyl alcohol) hydrogel for catheter motion. J Biomech Sci Eng. 2009;5:11–17.
14.
KogaMKimuraKMinematsuK, et al. Diagnosis of internal carotid artery stenosis greater than 70% with power Doppler duplex sonography. Am J Neuroradiol. 2001;22:413–417.
15.
KosukegawaHMamadaKKurokiK, et al. Measurements of dynamic viscoelasticity of poly (vinyl alcohol) hydrogel for the development of blood vessel biomodeling. J Fluid Sci Tech. 2008;3:533–543.
16.
BrunetteJMongrainRLaurierJ, et al. 3D flow study in a mildly stenotic coronary artery phantom using a whole volume PIV method. Med Eng Phys. 2008;30:1193–1200.
17.
BlakeJREassonWJHoskinsPR. A dual-phantom system for validation of velocity measurements in stenosis models under steady flow. Ultrasound Med Biol. 2009;35:1510–1524.
18.
ScheelPRugeCSchöningM. Flow velocity and flow volume measurements in the extracranial carotid and vertebral arteries in healthy adults: Reference data and the effects of age. Ultrasound Med Biol. 2000;26:1261–1266.
19.
SugawaraMNikiKFuruhataH, et al. Relationship between the pressure and diameter of the carotid artery in humans. Heart Vessels. 2000;15:49–51.
20.
TardyYMeisterJJPerretF, et al. Non-invasive estimate of the mechanical properties of peripheral arteries from ultrasonic and photoplethysmographic measurements. Clin Phys Physiol Meas. 1991;12:39–54.
21.
LiuLKosukegawaHOhtaM, et al. Anisotropic in vitro vessel model using poly(vinyl alcohol) hydro gel and mesh material. J Appl Pol Sci. 2010;116:2242–2250.
22.
KudoSSatoMMachidaK, et al. Macromolecule uptake into the cultured endothelial cells and the cell morphology in separated flow. Trans JSME B. 1999;639:3705–3712. (In Japanese.)
23.
KudoSMorigakiRSaitoJ, et al. Shear-stress effect on mitochondrial membrane potential and albumin uptake in cultured endothelial cells. Biochem Biophys Res Com. 2000;270:616–621.
24.
HelmlingerGGeigerRVSchreckS, et al. Effects of pulsatile flow on cultured vascular endothelial cell morphology. Trans ASME J Biomech Eng. 1991;113:123–131.
CaroCGFitzgeraJMSchroterRC. Arterial wall shear and distribution of early atheroma in man. Nature. 1969;223:1159–1161.
27.
CaroCGPedleyTJSchroterRC, et al. The mechanics of the circulation. Oxford: Oxford Univ. Press; 1978.
28.
KarinoTGoldsmithHL. Aggregation of human platelets in an annular vortex distal to tubular expansion. Microvasc Res. 1979;17:217–237.
29.
KarinoTGoldsmithHL. Adhesion of human platelets in an annular vortex distal to tubular expansion. Microvasc Res. 1979;17:238–262.
30.
MabuchiSAbeHKarinoT. Flow patterns at the bifurcation and curving portion of the human middle cerebral artery – With reference to the localization of atherogenesis. Neurol Med Chir. 1988;28:321–326. (In Japanese.)
31.
FukushimaKTamagawaMHiramotoM. Visualization of thrombus formation process and flow analysis on shear blood flow. Trans JSMBE. 2007;45:99–105. (In Japanese.)
32.
TamagawaM. Effects of high shear rate on thrombus formation rate on pipe orifice flows using laser sheet method and the prediction of thrombus formation rate by CFD. In: Proceedings of ASME 2012. 2012. doi:10.1115/IMECE2012-86806.