AbstractThe electrical conductances of LiCl in H2O and D2O solutions were measured in the temperature range 373 - 673 K at pressures up to 37.27 MPa, using a flow type electrical conductance cell.Keywordselectric conductanceLiClsupercritical watersubcritical waterheavy waterReferences1. Baumann E. , J. Chem. Eng. Data, 1993, 38, 12.2. Ho P. , Palmer D. , Mesmer R. , J. Solut. Chem., 1994, 23 (9), 997.3. Barthel J. , Feuerlein F. , Neueder R. , Wachter R. , J. Solut. Chem., 1980, 9(3), 209.4. Timrot D. , Shuiskaya K. , Atomnaya Energiya, 1959, 7, 459.