Abstract
Purpose
To describe modification of the Viabahn Padova Sutureless (ViPS) technique for challenging anastomosis between a prosthetic graft and a circumferentially calcified target artery.
Technique
The technique is demonstrated in a 75-year-old man with complete superficial femoral artery (SFA) occlusion and reconstitution of a circumferentially calcified above-knee popliteal artery. A 7-mm Viabahn endoprosthesis with its constraining string was withdrawn from its delivery system; the string at the proximal edge of the stent was gently cut with a scalpel, causing the proximal part of the stent to deploy, while the undeployed distal tip with its smooth profile retained its commercial orientation. The proximal end was subsequently sutured to a 7-mm polytetrafluoroethylene (PTFE) graft. After surgical exposure, the popliteal artery was transected, and the undeployed distal portion of the Viabahn was inserted into the distal segment, supported by a stiff guidewire. By pulling the constraining string, the stent was deployed in a “non-reversed” fashion and subsequently dilated to achieve optimal apposition. Finally, the proximal end of the PTFE graft was tunneled under the sartorius muscle and sutured to the common femoral artery.
Conclusion
This modification to the ViPS technique using a “non-reversed” method of Viabahn stent preparation allows a safer and more accurate deployment of the endoprosthesis in the calcified target artery.
Get full access to this article
View all access options for this article.