Abstract
Purpose:
To evaluate the role of aortic stent-graft implantation in managing aortobronchial fistula (ABF).
Methods:
A search of the Medline, EMBASE, and Cochrane databases for studies reporting on ABF treated with stent-grafts from 1996 to 2008 retrieved 44 articles with data on 82 ABFs. Most (57 ABFs) were published in 30 case reports; the others were retrieved from 14 acute aortic series.
Results:
In the perioperative period, 4 (4.9%) deaths (3 from hemorrhage) were reported, but no paraplegia/stroke. Local graft-related complications were more common, including arm ischemia (n=4) and iliac ruptures (n=3). Long-term data were available for only a few studies. Recurrent hemorrhage (14%) occurred from 2 weeks to 9 years after repair. Reinterventions to manage recurrences were generally based on redo endografting.
Conclusion:
A contaminated field and the emergency setting make stent-graft repair of ABFs challenging. After successful stent-graft deployment, the risks of recurrence and mortality are concerning. One can infer from the data that endografting might be a reasonable temporary bridge solution, but potentially unstable in the long term. Open repair likely will remain indicated once the patient has been stabilized physiologically with emergent stent-graft repair.