Emission line enhancement in a dc plasma seeded with an easily ionizable matrix salt is discussed. Enhancement is shown to be inversely related to the ionization potential of the matrix element. The temperature of the plasma core is shown to decrease in the presence of an easily ionizable element, while the effective temperature experienced by the analyte is shown to increase under the same conditions. The emission of the plasma is spatially profiled with and without an easily ionizable matrix element at the 425.4 nm Cr line, the 340.5 nm Co line, and the 334.5 nm Zn line.
GilbertT. R., Environ. Meas. Lab. Environ. Q (U.S. Department of Energy), EML-356, 429 (1979).
3.
NygaardD. D. and GilbertT. R., paper presented at International Winter Conference 1980 on Developments in Atomic Plasma Spectrochemical Analyses, San Juan, Puerto Rico, 1980.
4.
FelkelH. L.Jr. and PardueH. L., Anal. Chem.50, 602 (1978).
5.
DeckerR. J., Spectrochim. Acta35B, 19 (1980).
6.
BoumansP. W. J. M., Theory of Spectrochemical Excitation (Plenum, London, 1969), Chap. 7.
7.
AdcockB. D. and PlumtreeW. E. G., J. Quant. Spectrosc. Radiat. Transfer4, 29 (1964).
8.
JohnsonG. W.TaylorH. E., and SkogerboeR. K., Appl. Spectrosc.34, 19 (1980).
9.
FernandezM. A. and BastiaansG. J., Appl. Spectrosc.33, 145 (1979).