A technique is presented that allows for the determination of Sn, Pb, Zn, Ni, and Fe in copper base alloys. A spectrochemical solution procedure is described using a rotating disk technique with a 15 m Production Control Quantometer. The precision achieved is 0 5–15% of amount present for Sn (1.0–11.5%), Pb (0.05–8.0%), Zn (0 10–6.0%), Ni (0.05–1 0%), and 47% of amount present for Fe (0.01–0 50%).
Get full access to this article
View all access options for this article.
References
1.
YoungA. W., STEEL, 134, No. 24, 112 (1954)
2.
HarveyC. E., Spectrochemical Procedures, Applied Research Laboratories, Glendale, Cal., 1950.
3.
SPECTROGRAPHERS NEWS LETTER, 2, No. 9 (1948)
4.
BealeP. T. and PoynterD. A., METALLURGIA, 52, 253 (1955)