SparksJ.B., Histomap of World History.Rand McNally. Available from the John Sparks Trust Fund by contacting his granddaughter Jackie Glanz at jacquieglanz@yahoo.com
2.
DiamondJ., Guns, Germs, and Steel.W.W. Norton & Co., New York, USA, (1999).
3.
Tal'roseV.L.KarpovG.V.GorodetskiiI.G.SkuratV.E., “Capillary system for the introduction of liquid mixtures into an analytical mass-spectrometer”, Russ. J. Phys. Chem.42(12), 1658 (1968).
4.
DoleM.MackL.L.HinesR.L.MobleyR.C.FergusonL.D.AliceM.B., “Molecular beams of macroions”, J. Phys. Chem. Phys.49(1), 2240–2249 (1968). doi: 10.1063/1.1670391
5.
BaldwinM.S.McLaffertyF.W., “The direct introduction of liquid solutions into a chemical ionization mass spectrometer”, Org. Mass Spectrom.7, 1111–1112 (1973). doi: 10.1002/oms.1210070913
6.
CarrollC.I.DzidicR.N.StillwellR.N.HorningM.G.HorningF.C., “Subpicogram detection system for gas phase analysis based in atmospheric pressure ionization mass spectrometry”, Anal. Chem.46(6), 706 (1974). doi: 10.1021/ac60342a009
7.
BruinsA.P.NibberingN.M.M.de BoerTh.J., “A marked difference between the decomposing (M-H)+ ions from benzyl amine and p-aminotoluene, in the light of benzyl versus tropylium ion structures”, Tetrahedron Lett.13, 1109 (1972). doi: 10.1016/S0040-4039(01)84521-4
8.
BruinsA.P.NibberingN.M.M., “On the loss of a benzyl radical from the molecular ion of alpha, omegadibenzyloxyalkanes; evidence for a benzyl cation transfer in an SNi-type reaction, revealed by a simultaneous D- and 18O-labelling”, Tetrahedron30, 493 (1974). doi: 10.1016/S0040-4020(01)97030-9
9.
BruinsA.P.NibberingN.M.M.: “An ICR study on benzyl cation transfer reactions and the nucleophylic attack of amines on the C7H7+ ion from benzyl methyl ether”, Tetrahedron Lett.15, 2680 (1974). doi: 10.1016/S0040-4039(01)92326-3
10.
BruinsA.P.NibberingN.M.M., “An ICR study on benzoylation reactions in the gas phase”, Tetrahedron Lett.16, 4491 (1975). doi: 10.1016/S0040-4039(00)91101-8
11.
BruinsA.P.NibberingN.M.M., “Chain length effects in the competition between intramolecular hydrogen migrations in the molecular ions of alpha-benzylaminoomega-benzyloxyalkanes as studied by deuterium labeling”, Org. Mass Spectrom.11, 271 (1976). doi: 10.1002/oms.1210110307
12.
BruinsA.P.NibberingN.M.M., “Hydrogen scrambling in the long-lived protonated benzene ion generated from benzyl amine in the ICR spectrometer”, Org. Mass Spectrom.11, 950 (1976). doi: 10.1002/oms.1210110906
13.
BruinsA.P.JenningsK.R.EvansS., “The observation of metastable transitions in a double focusing mass spectrometer using a linked scan of the electric sector and magnetic sector fields”, Int. J. Mass Spectrom. Ion Phys.26, 395 (1978). doi: 10.1016/0020-7381(78)80058-8
14.
BoydR.K.BeynonJ.H., “Scanning sector mass spectrometers to observe the fragments of metastable ions”, Org. Mass Spectrom.12(3), 163 (1977). doi: 10.1002/oms.1210120311
15.
HenionJ.D., “Drug analysis by continuously monitored liquid chromatography/mass spectrometry with a quadrupole mass spectrometer”, Anal. Chem.50(12), 1887 (1978). doi: 10.1021/ac50034a029
16.
McFaddenW.H.SchwartzH.L.EvansS., “Direct analysis of liquid chromatographic effluents”, J. Chromatogr.122, 386–296 (1976). doi: 10.1016/S0021-9673(00)82261-X
17.
BruinsA.P., “Negative ion chemical ionization mass spectrometry in the determination of components in essential oils”, Anal. Chem.51, 967 (1979). doi: 10.1021/ac50043a043
18.
BruinsA.P., “A simple and inexpensive modification of a Finnigan 3300 quadrupole mass spectrometer for negative ion detection”, Biomed. Mass Spectrom.10, 46 (1983). doi: 10.1002/bms.1200100109
19.
BruinsA.P., “Probe for the introduction of nonvolatile samples into a chemical ionization source by thermal desorption from a platinum wire”, Anal. Chem.52, 605 (1980). doi: 10.1021/ac50053a063
20.
BruinsA.P., “Negative ion chemical ionization mass spectrometry of steroid glycosides by “in beam” sample introduction on glass rods and thermal desorption from a platinum wire”, Adv. Mass Spectrom.8, 246 (1980).
21.
BruinsA.P., “Negative ion desorption chemical ionization mass spectrometry of some underivatized glucuronides”, Biomed. Mass Spectrom.8, 31 (1981). doi: 10.1002/bms.1200080108
22.
ThomsonB.A.IribarneJ.V., “The fate of electrical charges in evaporating cloud droplets”, Rev. Geophys. Space Phys.16(3), 431–434 (1978). doi: 10.1029/RG016i003p00431
23.
ThomsonB.A.IrabarneJ.V., “Field induced ion evaporation from liquid surfaces at atmospheric pressure”, J. Chem. Phys.71(11), 4451–4463 (1979). doi: 10.1063/1.438198
24.
ThomsonB.A.IrabarneJ.V.DziedzicP.J., “Liquid ion evaporation/mass spectrometry/mass spectrometry for the detection of polar and labile molecules”, Anal. Chem.54, 2219–2224 (1982). doi: 10.1021/ac00250a020
25.
BruinsA.P.DrenthB.F.H., “Experiments with the combination of a micro liquid chromatograph and a chemical ionization quadrupole mass spectrometer, using a capillary interface for direct liquid introduction. Some theoretical considerations concerning the evaporation of liquids from capillaries into vacuum”, J. Chromatogr.271, 71 (1983). doi: 10.1016/S0021-9673(00)80200-9
26.
BlakleyC.R.CarmodyJ.J.VestalM.L., “Liquid chromatograph-mass spectrometer for analysis of nonvolatile samples”, Anal. Chem.52, 1636 (1980). doi: 10.1021/ac50061a025
27.
WilloughbyR.C.BrownerR.F., “Monodisperse aerosol generation interface for combining liquid chromatography with mass spectrometry”, Anal. Chem.56, 2626–2631 (1984). doi: 10.1021/ac00278a003
28.
BarberM.BordoliR.S.SedgwickR.D.TylerA.N., “Fast atom bombardment of solids (FAB)—a new ion source for mass spectrometry”, J. Chem. Soc. Chem. Commun.325–327 (1981). doi: 10.1039/c39810000325
29.
ItoY.TakeuchiT.IshiiD.GotoM., “Direct coupling of micro-high performance liquid chromatography with fast atom bombardment mass spectrometry”, J. Chromatogr.346, 161–166 (1985). doi: 10.1016/S0021-9673(00)90502-8
30.
CaproliR.M.FanT.CottrellJ.S., “Continuous-flow sample probe for fast atom bombardment mass spectrometry”, Anal. Chem.58, 2949–2954 (1986). doi: 10.1021/ac00127a012
31.
HenionJ.D.ThomsonB.A.DawsonP.H., “Determination of sulfa drugs in biological fluids by liquid chromatography/mass spectrometry/mass spectrometry”, Anal. Chem.54, 451–456 (1982). doi: 10.1021/ac00240a023
32.
CoveyT.R.LeeE.D.HenionJ.D., “High-speed liquid chromatography/tandem mass spectrometry for the determination of drugs in biological samples”, Anal. Chem.58, 2453–2460 (1986). doi: 10.1021/ac00125a022
33.
HopfgartnerG.BourgogneE., “Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry”, Mass Spectrom. Rev.22, 195–214 (2003). doi: 10.1002/mas.10050
34.
LeeM.S., Integrated Strategies for Drug Discovery using Mass Spectrometry.John Wiley & Sons, Inc.New York, USA, 568 pp. (2005). doi: 10.1002/0471721034
35.
LeeM.S., LC/MS Applications in Drug Development.John Wiley & Sons, Inc.New York, USA, 256 pp. (2002).
36.
FrenchJ.B.ReidN.M.BuckleyJ.A., “Apparatus for analyzing trace components in air, US Patent 4,023,398, (1977).
37.
YamashitaM.FennJ.B., “Electrospray ion source. Another variation on the free-jet theme”, J. Phys. Chem.88, 4451–4459 (1984). doi: 10.1021/j150664a002
38.
AlexandrovM.L.GallL.N.KrasnovN.V.NikolaevV.I.PavlenkoV.A.ShkurovV.A., “Extraction of ions from solution under atmospheric pressure as a method for mass spectrometric analysis of bioorganic compounds”, Dolk. Adak. Nauk SSSR277, 379–383 (1984). English translation re-published in Rapid Commun. Mass Spectrom.22, 267–270 (2008).
39.
BruinsA.P.CoveyT.R.HenionJ.D., “Ion spray interface for combined liquid chromatography/atmospheric pressure ionization mass spectrometry”, Anal. Chem.59, 2642–2646 (1987). doi: 10.1021/ac00149a003
40.
BruinsA.P., “Mass spectrometry with ion sources operating at atmospheric pressure”, Mass Spectrom. Rev.10, 53–77 (1991). doi: 10.1002/mas.1280100104
41.
RaffaelliA.BruinsA.P., “Factors affecting the ionization efficiency of quaternary ammonium compounds in electrospray/ionspray mass spectrometry”, Rapid Commun. Mass Spectrom.5, 269–275 (1991). doi: 10.1002/rcm.1290050605
42.
KostiainenR.BruinsA.P., “Effect of multiple sprayers on dynamic range and flow rate limitations in electrospray and ionspray mass spectrometry”, Rapid Commun. Mass Spectrom.8, 549–558 (1994). doi: 10.1002/rcm.1290080712
43.
KostiainenR.BruinsA.P., “Effect of solvent on dynamic range and sensitivity in pneumatically assisted electrospray (ionspray) mass spectrometry”, Rapid Commun. Mass Spectrom.10, 1393–1399 (1996). doi: 10.1002/(SICI)1097-0231(199608)10:11<1393::AID-RCM654>3.0.CO;2-V
44.
ZookD.R.BruinsA.P., “On cluster ions, ion transmission, and linear dynamic range limitations in electrospray (ionspray) mass spectrometry”, Int. J. Mass Spectrom. Ion Processes162, 129–147 (1997). doi: 10.1016/S0168-1176(96)04511-9
45.
FennJ.B.MannM.MengC.K.WongS.F.WhitehouseC.M., “Electrospray ionization for mass spectrometry of large biomolecules”, Science246, 64–70, (1989). doi: 10.1126/science.2675315
46.
CoveyT.R.BonnerR.F.ShushanB.I.HenionJ., “The determination of protein, oligonucleotide, and peptide molecular weights”, Rapid Commun. Mass Spectrom.2(11), 249–256 (1988). doi: 10.1002/rcm.1290021111
47.
WilmM.MannM., “Electrospray and Taylor–Cone theory. Dole's beam of macromolecules at last?”Int. J. Mass Spectrom. Ion Processes136, 167–180 (1994). doi: 10.1016/0168-1176(94)04024-9
48.
ValaskovicG.A.McLaffertyF.W., “Long-lived metallized tips for nanoliter electrospray mass spectrometry”, J. Am. Soc. Mass Spectrom.7, 1270–1272 (1996). doi: 10.1016/S1044-0305(96)00152-3
49.
SchultzG.A.CorsoT.N.ProsserS.J.ZhangS., “A fully integrated monolithic microchip electrospray device for mass spectrometry,”Anal. Chem.72, 4058–4063 (2000). doi: 10.1021/ac000325y
50.
CoveyT.R., “Development of gas dynamic focusing for pneumatically assisted electrospray (ionspray) sample introduction”, presented at the 42nd American Society for Mass Spectrometry Conference, Chicago. USA (1994).
51.
CoveyT.R., “Analytical characterisitics of the electrospray ionization process”, in Biochemical and Biotechnological Applications of Electrospray Ionization Mass Spectrometry—ACS Symposium Series 619, Chapter 2, Ed by SnyderA.P., American Chemical Society, Washington, DC, USA (1995).
52.
CoveyT.R., “Pneumatically assisted electrospray”, in Encyclopedia of Mass Spectrometry, Ed by GrossM.CaprioliR.,. Volume 6, Ionization Methods. Elsevier Ltd, Oxford, UK, pp. 426–435 (2007).
53.
WangT.ZengL.CohenJ.KasselD.B., “A multiple electrospray interface for parallel mass spectrometric analyses of compound libraries”, Comb. Chem. High T. Scr.2, 327–334 (1999).
54.
SchneiderB.B.CoveyT.R., “Multiple sprayers in electrospray ionization”, in Encyclopedia of Mass Spectrometry, Ed by GrossM.CaprioliR., Volume 6, Ionization Methods. Elsevier Ltd, Oxford, UK, pp. 456–467 (2007).
55.
RobbD.B.CoveyT.R.BruinsA.P., “Atmospheric pressure photoionization: An ionization method for liquid chromatography/mass spectrometry”, Anal. Chem.72, 3653–3659, (2000). doi: 10.1021/ac0001636
56.
KauppilaT.J.KostiainenR.BruinsA.P., “Anisole, a new dopant for atmospheric pressure photoionization mass spectrometry of low proton affinity, low ionization energy compounds”, Rapid Commun. Mass Spectrom.18, 808–815 (2004). doi: 10.1002/rcm.1408
57.
Van BerkelG.J.PasilisS.P.OvchinnikovaO., “Established and emerging atmospheric pressure surface sampling/ionization techniques for mass spectrometry”, J. Mass Spectrom.43, 1161–1180 (2008). doi: 10.1002/jms.1440
58.
KerteszV.FordM.J.Van BerkelG.J., “Automation of a surface sampling probe/electrospray mass spectrometry system”, Anal. Chem.77(22), 7183–7189 (2005). doi: 10.1021/ac0510742
59.
CooksR.G.OuyangZ.TakatsZ.WisemanJ.M., “Ambient mass spectrometry”, Science311, 1566–1570 (2006). doi: 10.1126/science.1119426
60.
CodyR.B.LarameeJ.A., “Versatile new ion source for the analysis of materials in open air under ambient conditions”, Anal. Chem.77, 2297–2302 (2005). doi: 10.1021/ac050162j
61.
McEwenC.N.McKayR.G.LarsenB.S., “The analysis of solids, liquids, and biological tissues using solids probe introduction at atmospheric pressure on commercial LC/MS instrumentation”, Anal. Chem.77, 7826–7831, (2005). doi: 10.1021/ac051470k
62.
PicardP.CarrierV.PaquinR., “Atmospheric pressure Laser Diode Thermal Desorption Mass Spectrometry: A new high performance ionization source”, Presented at the 54th American Society Mass Spectrometry Conference, San Antonio, USA (2005).
63.
GetekT.A.KorfmacherW.A.McRaeT.A.HinsonJ.A., “Utility of solution electrochemistry mass spectrometry for investigating the formation and detection of biologically important conjugates of acetaminophen”, J. Chromatogr.474, 245–256 (1989). doi: 10.1016/S0021-9673(01)93919-6
64.
GuoX.BruinsA.P.CoveyT.R., “Characterization of typical chemical backround interferences in atmospheric pressure ionization liquid chromatography-mass spectrometry”, Rapid Commun. Mass Spectrom.20, 3145–3150 (2006). doi: 10.1002/rcm.2715
65.
GuoX.BruinsA.P.CoveyT.R., “Method to reduce chemical background Interference in atmospheric pressure ionization liquid chromatography-mass spectrometry using exclusive reactions with the chemical reagent dimethyl disulfide”, Anal. Chem.79, 4013–4021 (2007). doi: 10.1021/ac062365t
66.
JurvaU.WikströmH.V.BruinsA.P.: “In vitro mimicry of metabolic oxidation reactions by electrochemistry/mass spectrometry”, Rapid Commun. Mass Spectrom.14, 529–533 (2000). doi: 10.1002/(SICI)1097-0231(20000331)14:6<529::AID-RCM904>3.0.CO;2-H
67.
PermentierH.P.BruinsA.P., “Electrochemical oxidation and cleavage of proteins with on-line mass spectrometric detection: Development of an instrumental alternative to enzymatic protein digestion”, J. Am. Soc. Mass Spectrom.15, 1707–1716 (2004). doi: 10.1016/j.jasms.2004.09.003