This paper describes a diagnostic system for the fuel injection module in a high-speed forging machine. The system is based on the use of fuzzy sets techniques, with a fuzzy set representing each fault in the module. Empirical membership functions for the different fuzzy sets are employed to locate faults according to conditions observed on the forging machine. Two types of faults can be handled: faults due to one of more valves in the fuel injection module remaining in their unenergized state and faults caused by a valve being stuck in the energized state. Details of the diagnostic methods for both fault types are presented following a brief review of the operating principle of the forging machine.