Abstract
The compressor design requirement was for a pressure ratio of 3.6, with a peak pressure ratio of 4.3 at the maximum non-dimensional speed of the impeller of 1.66. Due to the stress-limited speed, an aluminium alloy impeller was specified, the impeller discharge blade backsweep had to be restricted and the application of prewhirl was considered from the outset as a means of extending the operating range. A non-dimensional conceptual design procedure, including the effect of inlet prewhirl, was applied to the design of three turbo- charger impellers. An impeller, designated A, was designed with the inclusion of 25° of prewhirl. A second impeller, designated B, was designed with zero prewhirl for comparison purposes, but was not manufactured. A third impeller, C, was manufactured through the modification of an existing design and the design study was applied to the assessment of this third design.
Get full access to this article