It is shown that the heat lost from the sensing element of a hot film anemometer under the condition of no imposed flow is affected by the pressure when the fluid is compressible. A method is proposed for plotting the calibration results in order to make the resulting chart applicable over a wide range of pressures.
Get full access to this article
View all access options for this article.
References
1.
KingL. V.‘On the convection of heat from small cylinders in a stream of fluid’, Phil. Trans. R. Soc.1914214, (Series A), 373.
2.
Al'OmarA. F.‘Combustion problems in Petro-Forge’, Ph.D. thesis, University of Birmingham, 1968.
3.
Van Der HeggeZijnen B. G.‘Modified correlation formulae for heat transfers by natural and by forced convection from horizontal cylinders’, Appl. scient. Res.19566, (Sec. A, Nos 2–3), 129.