The shear strength of the femoral bone-cement interface using four current techniques of cement insertion in total hip replacement was compared in paired human and ox femora. Ox bone proved to have mechanical properties comparable to human material, gave reproducible results, and was more readily available. In clean bone, lowering cement viscosity resulted in better bone fixation. When a thin layer of blood was interposed on brushed, washed bone, the interface strength was halved. Lower viscosity cementing techniques in the presence of blood conferred no advantage over cement inserted as thick dough.
Get full access to this article
View all access options for this article.
References
1.
BenjaminJ. B.GieG. A.LeeA. J. C.LingR. S. M.VolzR. G. (1987) Cementing technique and the effect of bleeding, J. Bone Jt Surg.69B, 620–624.
2.
GrissP.HackenbrochM. H.JagerM.PreussnerB.SchaferT.SeebauerR.Van EimerenW.WinklerW. (1982) Findings on total hip replacement for ten years.Hans Huber, Berne, Stuttgart, Vienna.
3.
HalawaM.LeeA. J. C.LingR. S. M.LingR. S. M.VangalaS. S. (1978) The shear strength of trabecular bone from the femur and some factors affecting the shear strength of the cement-bone interface, Archiv. Orthop. Traumatic Surg.92, 19–30.
4.
KrauseW. R.KrugB.MillerJ. (1982) Strength of the bone-cement interface, Clin. Orthop. Rel. Res., 163, 290–299.