Glutaraldehyde fixation of bovine pericardium produces a material which is more extensible than the natural tissue. Chemically modified pericardial sacs from 16–20 week old calves provide a region 12 000 mm2 in area which has relatively uniform properties. Tricuspid heterografts constructed from this material have maximal bending stresses at two sites associated with valve failure through mechanical tissue fatigue.
Get full access to this article
View all access options for this article.
References
1.
BartekI. T.HoldenM. P.IonescuM. I. (1974) Frame mounted tissue heart valves: Techniques of construction, Thorax, 29, 51–57.
2.
ChristieG. W.MedlandI. C. (1980) A static, finite strain, finite element analysis of bioprosthetic heart valves, Int. Conf. on finite elements in Biomechanics, pp. 605–622.
3.
ClarkeE.SuteraS. P. (1973) Methods of design of leaflet valvular prostheses I. Stresses in the mitral valve leaflets in health and disease, J. Thorac. Cardiovasc. Surg., 65, 890–896.
4.
ClarkR. E.KararaH. M.CatalogluA.GouldP. L. (1975) Close range sterophotogrammetry and coupled stress analysis as tools in the development of prosthetic devices, Trans. Amer. Soc. Artif. Int. Organs., 21, 71–78.
5.
GabbayS.BortollottiU.WassermanF.FactorS.StromJ.FraterR. W. (1984) Fatigue-induced failure of the Ionescu–Shiley pericardial xenograft in the mitral position: In vivo and in vitro correlation and a proposed classification, J. Thorac. Cardiovasc. Surg., 87, 836–844.
6.
GhistaD. N.RaoA. P. (1972) Structural mechanics of the mitral valve: Stresses sustained by the valve; non-traumatic determination of the stiffness of the ‘in vivo’ valve, J. Biomech., 5, 295–307.
7.
GhistaD. N.ReulH. (1977) Optimal prosthetic aortic leaflet valve: Design parametric and longevity analyses: Development of the avcothane-51 leaflet valve based on the optimum design analysis, J. Biomech., 10, 313–324.
8.
IonescuM. I.TandonA. P. (1979) The Ionescu–Shiley pericardial xenograft heart valve, In Tissue Heart Valves, (Edited by IonescuM. I.) Butterworths, London. pp. 201–252.
9.
ThubrikarM LPeipgrassW. C.DeckJ. D.NolanS. P. (1980) Stresses of natural versus prosthetic aortic valve leaflets in vivo, Ann. Thorac. Surg., 30, 230–239.
10.
TimoshenkoS.KriegerWoinowsky S. (1959) Theory of plates and shells, McGraw Hill, New York, pp. 415–418.
11.
TrowbridgeE. A.CroftsC. E. (1986) Evidence that deformations which occur during mechanical conditioning of bovine pericardium are not permanent, Biomaterials, 7, 49–54.
12.
TrowbridgeE. A.CroftsC. E. (1987) Pericardial heterografts: An assessment of leaflet stresses and the implications for valve design, J. Biomed. Engng, in press.
13.
TrowbridgeE. A.BlackM. M.DanielC. L. (1985) The mechanical response of glutaraldehyde-fixed bovine pericardium to uniaxial load, J. Mat Sci, 20, 114–140.
14.
WoodroofE. A. (1979) The chemistry and biology of aldehyde treated tissue heart valve xenografts, In Tissue Heart Valves (Edited by IonescuM. I.) Butterworths, London, pp. 347–362.