A whole range of laboratory testing methods for prosthetic heart valves, such as steady flow testing, pulsatile flow testing, and fatigue testing, are presented. Comparative test results for various valve types are given and relative valve performance is discussed.
Get full access to this article
View all access options for this article.
References
1.
BrussK. H.ReulH.Van GilseJ.KnottE. (1983) Pressure drop and velocity fields at four mechanical heart valve prostheses: Björk–Shiley Standard, Björk–Shiley Concave–Convex, Hall–Kaster, and St. Jude Medical, Life Support Systems, 1, 3–22.
2.
ChandranK. B.CabellG. N., et al. (1983) Laser anemometry measurements of pulsatile flow past aortic valve prostheses, J. Biomechs, 16, 865.
3.
ClarkR. E.SwansonW. M., et al. (1978) Durability of prosthetic heart valves, Ann. Thorac. Surg., 26, 323–334.
4.
FigliolaR. S.MuellerT. J.Fluid stresses in the vicinity of disc ball and tilting disc prosthetic heart valves from in vitro measurements, J. Biol. Mech. Engng, 99, 173.
5.
GabbayS.BartolottiU.JosifM. (1986) Mechanical factors influencing the durability of heart valve pericardial bioprostheses, TASAIO.
6.
GiersiepenM.ReulH.KnochM.RauG. (1986) Pressure drop and velocity fields of mechanical heart valves, Proc. of the 13th ESAO-Conference 1986, Saunders, UK.
7.
HeroldM.LoH. B., et al. (1986) The Helmholtz-Institute tri-leaflet PU heart valve prostheses: Design, manufacturing and first in vitro and in vivo results, Proceedings of the 2nd Int. Conf. on Polyurethanes in Biomed. Engng, Stuttgart, West Germany, 1986, Elsevier, Holland.
8.
KnottE.ReulH.SteinseiferU. (1986) Pressure drop, energy loss and closure volume of prosthetic heart valves in aortic and mitral position under pulsatile flow conditions. Proc. of the 13th ESAO-Conference 1986, Saunders, UK.
ReulH. (1983) In-vitro evaluation of artificial heart valves, Adv. Cardiovasc. Phys, 5, part IV, 16–30, (Korger, Basel).
11.
ReulH. (1984) Cardiovascular simulation models, Life Support Systems, 2, 77–98.
12.
ReulH.GiersiepenM.SchindehütteH.EffertS.RauG. (1986) Comparative in vitro evaluation of porcine and pericardial bioprostheses, Z. Kardiol., 75, Suppl. 2, 223–231.
13.
ScottenL. N.WalkerD. K.BrownleeR. T. (1984) Prosthetic mitral valve orientation – its effect on valve function in vitro, (Proc. 11. ESAO Meeting 1984)Life Support Systems, 2, Suppl. 1, 86–88.
14.
SwansonW. M.ClarkeR. E. (1974) Dimensions and geometric relationship of the human aortic valve as a function of pressure, Circulation Res., 35, 871.
15.
WooY. R.YoganathanA. P. (1985) In vitro pulsatile flow velocity and turbulent shear stress measurements in the vicinity of mechanical heart valve prostheses, Life Support Systems, 3, 283–312.