Earlier works, here briefly summarized, described the experimental techniques used for the stress analysis of the stem–femur coupling. Special strain-gauge transducers were constructed in the shape of endoprosthesis stems, to be implanted in test femurs. Four types of such transducers have been evolved, in order to overcome problems encountered during tests. The transducers are described, and results obtained with the third of these are shown in detail.
BreyerH. G.Enes-GaiaoF.KuehnH. J. (1979) Biegebeanspruchung des Femur-kopfprosthesenschaftes bei pertrochanterer Osteotomie. Pauwels Symp., Freie Univ., Berlin, Jan.
3.
CalderaleP. M.GolaM. M.GugliottaA. (1979) New theoretical and experimental developments in the mechanical design of implant stems. Pauwels Symp., Freie Univ., Berlin, Jan.
4.
CalderaleP. M.GolaM. M.GugliottaA. (1980a) Experimental results for stem-femur couplings loaded in bending. Al II-lea Simpozion National de Tensometrie, Cluj-Napoca, Romania, June.
5.
CalderaleP. M.GolaM. M.GugliottaA. (1980b) Analisi teorica e sperimentale dello stato di tensione in steli protesici (II). VIII Conv. Naz. AIAS, Florence, Sept.
6.
CrowninshieldR. D.BrandR. A.JohnstonR. C. (1979) An analysis of femoral stem design in total hip arthroplasty. 25th Ann. Meet. Orthop. Res. Soc, San Francisco, Feb.
7.
GolaM. M.GugliottaA. (1979) Analytical estimate of stresses in bones and prosthesis stems. J. Strain Anat., 14, No. 1.
8.
HuiskesR. (1977) Strain-gage measurements on loaded femur, intact as well as provided with orthopaedic implants. Poster Session, Biomechanics VI, Copenhagen.
9.
HuiskesR.SlooffT. J. (1979) Experimentelle und rechnerische Spannungs-analyse der Hueftgelenkverankerung. Pauwels Symp., Freie Univ., Berlin, Jan.
10.
HuiskesR. (1980) Some fundamental aspects of human joint replacement. Acta Orthop. Scand., Suppl. 185.
11.
JakobH. A. C.HugglerA. H.SchreiberA. (1979) Spannungsanalysen an Kunstsoff modellen des menschlichen Beckens sowie des proximalen Femurendes mit und ohne Prothese. Pauwels Symp., Freie Univ., Berlin, Jan.
12.
JakobH. A. C.HugglerA. H. (1980) An investigation into biomechanical causes of prosthesis stem loosening within the proximal end of the human femur. J. Biomech., 13, 159–173.
13.
MarkolfK. L.AmstutzH. C. (1976) A comparative experimental study of stresses in femoral hip replacement components: The effect of prosthesis orientation and acrylic fixation. J. Biomech., 9.
14.
MizrahiJ.LivingstoneR. P.RoganI. M. (1979) An experimental analysis of the stresses at the surface of Charnley hip prostheses in different anatomical positions. J. Biomech., 12.
15.
RoehrleH.ScholtenR.SollbachW. (1979) Der Kraftluss bei neuartigen Hueftendoprothesen. Pauwels Symp., Freie Univ.Berlin, Jan.
16.
SvenssonN. L.ValliappanS.WoodR. D. (1977) Stress analysis of human femur with implanted Charnley prosthesis. J. Biomech., 10.
17.
TarrR. R.LewisJ. L. (1979) Effects of materials, stem geometry and collar-calcar contact on stress distribution in the proximal femur with a total hip. 25th Ann. Meet. Orthop. Res. Soc, San Francisco, Feb.
18.
WeightmanB. (1976) The stress in total hip prosthesis femoral stems: Comparative experimental study. Artificial hip and knee technology, Springer, Berlin.
19.
WoodR. D. (1975) Stress analysis of femur. PhD. Thesis Univ. of New South Wales, Australia.