Abstract
The 11 March 2011 M 9.0 Tohoku earthquake generated long-duration shaking that propagated hundreds of kilometers from the epicenter and affected tall buildings in urban areas several hundred kilometers from the epicenter of the main shock. Recorded responses show that tall buildings were affected by long-period motions. This study presents the behavior and performance of a 37-story building in the Tsukuda area of Tokyo, Japan, as inferred from modal analyses of records retrieved for a time interval covering a few days before, during, and for several months after the main shock. The U.S. “code-type” array comprises three triaxial accelerometers deployed at three levels in the superstructure. Such a sparse array in a tall structure limits a reliable assessment, because its performance must be based on only the average drift ratios. Based on the inferred values of this parameter, the subject building was not structurally damaged.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.