Gu YJ, Boonstra PW, Rijnsburger AAet al.Cardiopulmonary bypass circuit treated with surface-modifying additives: a
clinical evaluation of blood compatibility. Ann Thorac Surg1998; 65: 1342-1347.
2.
Defraigne JO, Pincemail J, Dekoster Get al.SMA circuits reduce platelet consumption and platelet factor release during
cardiac surgery. Ann Thorac Surg2000; 70: 2075-2081.
3.
Rubens FD, Labow RS, Lavallee GRet al.Hematologic evaluation of cardiopulmonary bypass circuits prepared with a
novel block co-polymer. Ann Thorac Surg1999; 67: 689-698.
4.
Eberhart RC, Li J, Sly MKet al.Scintigraphic analysis of cell adhesion in oxygenators and internal organs. The 23rd Annual Meeting, Society for Biomaterials,
New Orleans, LA, USA1997.
5.
Tanaka M, Motomura T, Kawada Met al.Blood compatible aspects of poly(2-methoxyethylacrylate) (PMEA) -
relationship between protein adsorption and platelet adhesion on PMEA surface. Biomaterials2000; 21: 1471-1481.
6.
Saito N, Motoyama S, Sawamoto J.Effect of new polymer-coated extracorporeal circuits on biocompatibility
during cardiopulmonary bypass. Artificial Organs2000; 24: 547-554.
7.
Schiel L, Burns S, Nogawa Aet al.X coating: a new biopassive polymer coating. Can Perfusion2001; 11: 8-17.
8.
Moen O, Hogasen K, Fosse Eet al.Attenuation of changes in leukocyte surface markers and complement
activation with heparin-coated cardiopulmonary bypass. Ann Thorac Surg1997; 63: 105-111.
9.
Hsu LC.Heparin-coated cardiopulmonary bypass circuits: current status. Perfusion2001; 16: 417-428.
10.
Gunaydin S.Clinical performance and hemobiocompatibility of new polymer
(poly2-methoxyethylacry-late) coated extracorporeal circuit - a comparative
study. Ann Thorac Surg in press.
11.
Gourlay T.Biomaterial development for cardiopulmonary bypass. Perfusion2001; 16: 381-390.
12.
Horisberger J, Jegger D, Boone Yet al.Impact of a remote pump head on neonatal priming volumes. Perfusion1999; 14: 351-356.
13.
De Somer F, Foubert L, Poelaert, Dujardin D, Van Nooten G, Francois K.Low extracorporeal priming volumes for infants: a benefit? Perfusion1996; 11: 445-460.
14.
McCusker K, Vijay V, DeBois Wet al.MAST system: a new condensed cardiopulmonary bypass circuit for adult
cardiac surgery. Perfusion2001; 16: 447-452.
15.
McCusker K, Vijay V, Helm Vet al.Clinical outcomes of complete X-coating circuit in MAST condensed bypass setting. J Extra Corporeal Technol2002; 34: 78-81.
16.
Harig F, Hohenstein B, von der Emde Jet al.Modulating IL-6 and IL-10 levels of pharmacologic strategies and the impact
of different extracorporeal circulation parameters during cardiac surgery. Shock2001; 16(Suppl 1): 33-38.
17.
Harig F, Feyrer R, Mahmoud FOet al.Reducing the post-pump syndrome by using heparin-coated circuit, steroids,
or aprotinin. Thorac Cardiovasc Surg1999; 47: 111-118.
18.
Gott JP, Cooper WA, Schmidt FE Jret al.Modifying risk for extracorporeal circulation: trial of four
anti-inflammatory strategies. Ann Thorac Surg1998; 66: 747-753.
19.
Larsson R, Elgue G, Larsson Aet al.Inhibition of complement activation by soluble recombinant CR1 under
conditions resembling those in a cardiopulmonary circuit: reduced
up-regulation of CD11b and complete abrogation of binding of PMNs to the
biomaterial surface. Immunopharmacology1997; 38: 119-127.
20.
De Somer F, Van Belleghem Y, Caes Fet al.Phosphor-ylcholine coating offers natural platelet preservation during
cardiopulmonary bypass. Perfusion2002; 17: 39-44.