This meta-analysis reviewed 12 studies comparing patient-specific instrumentation (PSI) with standard instrumentation (SI) for total knee arthroplasty in terms of postoperative coronal alignment and operation time. There is no significant difference between PSI and SI in terms of hip-knee-ankle angle (overall coronal alignment or mechanical axis), tibial coronal alignment, and operation time.
KurtzSOngKLauEMowatFHalpernM. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am2007;89:780–5.
2.
LombardiAVJrBerendKRAdamsJB. Patient-specific approach in total knee arthroplasty. Orthopedics2008;31:927–30.
3.
NoblePCCondittMACookKFMathisKB. The John Insall Award: Patient expectations affect satisfaction with total knee arthroplasty. Clin Orthop Relat Res2006;452:35–43.
4.
WhiteDCheluleKLSeedhomBB. Accuracy of MRI vs CT imaging with particular reference to patient specific templates for total knee replacement surgery. Int J Med Robot2008;4:224–31.
5.
AstMPNamDHaasSB. Patient-specific instrumentation for total knee arthroplasty: A review. Orthop Clin North Am2012;43:e17–22.
6.
LombardiAVJrFryeBM. Customization of cutting blocks: Can this address the problem?Curr Rev Musculoskelet Med2012;5:309–14.
7.
BarrackRLRuhELWilliamsBMFordADForemanKNunleyRM. Patient specific cutting blocks are currently of no proven value. J Bone Joint Surg Br2012;94(11Suppl A):95–9.
8.
BoonenBSchotanusMGKortNP. Preliminary experience with the patient-specific templating total knee arthroplasty. Acta Orthop2012;83:387–93.
9.
DaniilidisKTibeskuCO. A comparison of conventional and patient-specific instruments in total knee arthroplasty. Int Orthop2014;38:503–8.
10.
NunleyRMEllisonBSZhuJRuhELHowellSMBarrackRL. Do patient-specific guides improve coronal alignment in total knee arthroplasty?Clin Orthop Relat Res2012;470:895–902.
11.
RohYWKimTWLeeSSeongSCLeeMC. Is TKA using patient-specific instruments comparable to conventional TKA? A randomized controlled study of one system. Clin Orthop Relat Res2013;471:3988–95.
12.
VictorJDujardinJVandenneuckerHArnoutNBellemansJ. Patient-specific guides do not improve accuracy in total knee arthroplasty: A prospective randomized controlled trial. Clin Orthop Relat Res2014;472:263–71.
13.
VundelinckxBJBruckersLDe MulderKDe SchepperJVan EsbroeckG. Functional and radiographic short-term outcome evaluation of the Visionaire system, a patient-matched instrumentation system for total knee arthroplasty. J Arthroplasty2013;28:964–70.
14.
BarkeSMusanhuEBuschCStaffordGFieldR. Patient-matched total knee arthroplasty: Does it offer any clinical advantages?Acta Orthop Belg2013;79:307–11.
15.
ChareancholvanichKNarkbunnamRPornrattanamaneewongC. A prospective randomized controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J2013;95-B:354–9.
16.
HamiltonWGParksNLSaxenaA. Patient-specific instrumentation does not shorten surgical time: A prospective, randomized trial. J Arthroplasty2013;28(8 Suppl):96–100.
17.
NunleyRMEllisonBSRuhELWilliamsBMForemanKFordAD. Are patient-specific cutting blocks cost-effective for total knee arthroplasty?Clin Orthop Relat Res2012;470:889–94.
18.
NgVYDeClaireJHBerendKRGulickBCLombardiAVJr. Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res2012;470:99–107.
19.
LombardiAVJrBerendKRNgVY. Neutral mechanical alignment: A requirement for successful TKA: Affirms. Orthopedics2011;34:e504–6.
20.
BerendMERitterMAMedingJBFarisPMKeatingEMRedelmanR. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res2004;428:26–34.
21.
MahoneyOM. The role of alignment in TKR survivorship. Paper presented at Orthopedics Today Hawaii 2010; January 10–13, 2010; Kohala Coast, Hawaii.
22.
ParratteSPagnanoMWTrousdaleRTBerryDJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am2010;92:2143–9.
23.
JefferyRSMorrisRWDenhamRA. Coronal alignment after total knee replacement. J Bone Joint Surg Br1991;73:709–14.
24.
RitterMAFarisPMKeatingEMMedingJB. Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res1994;299:153–6.
25.
LustigSScholesCJOussedikSIKinzelVCoolicanMRParkerDA. Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. J Arthroplasty2013;28:469–73.
26.
NamDMaherPARebolledoBJNawabiDHMcLawhornASPearleAD. Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty. Knee2013;20:263–7.
27.
TibeskuCOHoferPPortegiesWRuysCJFennemaP. Benefits of using customized instrumentation in total knee arthroplasty: Results from an activity-based costing model. Arch Orthop Trauma Surg2013;133:405–11.
28.
HeyseTJTibeskuCO. Improved femoral component rotation in TKA using patient-specific instrumentation. Knee2014;21:268–71.