We present a case of Mycobacterium chelonae infection after total knee arthroplasty in a 70-year-old woman. The patient underwent implant removal, drainage, debridement, and insertion of a gentamycin-load cement spacer. After 4 months, the second-stage surgery was performed. Intravenous amikacin (6 weeks) and oral clarithromycin (12 weeks) were given. At the 12-month follow-up, the patient achieved 90° of flexion and could walk with a stick for up to 15 minutes. She was not taking any analgesics.
MillerMD. Review of orthopaedics, 5th ed.2008:306–58.
2.
EidAJBerbariEFSiaIGWengenackNLOsmonDRRazonableRR. Prosthetic joint infection due to rapidly growing mycobacteria: Report of 8 cases and review of the literature. Clin Infect Dis2007;45:687–94.
3.
GriffthDEAksamitTBrown-ElliottBACatanzaroADaleyCGordinF. An official ATS/IDSA statement: Diagnosis, treatment, and prevention of nontuberculous mycobacterial diseases. Am J Respir Crit Care Med2007;175:367–416.
4.
Bergogne-BerezinENouhouayiAPierreJ. Suppuration sur prothese de hance a Mycobacterium chelonei.Rev Fr Mal Resp1976;4:211–2.
5.
WongTCChanWFTsangWLYeungSHIpFK. Mycobacterium farcinogenes infection after total hip arthroplasty. J Arthroplasty2005;20:684–7.
6.
RunyonEH. Anonymous mycobacteria in pulmonary disease. Med Clin North Am1959;43:273–90.
7.
PringMEckhoffDG. Mycobacterium chelonae infection following a total knee arthroplasty. J Arthroplasty1996;11:115–6.
8.
MathewsPVKaneTJ3rd. Total hip arthroplasty infection with Chlamydia pneumoniae and Mycobacterium chelonae.Orthopedics2005;28:609–10.
9.
BrownAGrubbsPMongeyAB. Infection of total hip prosthesis by Mycobacterium tuberculosis and Mycobacterium chelonae in a patient with rheumatoid arthritis. Clin Rheumatol2008;27:543–5.
10.
JacobsCChristensenCPBerendME. Static and mobile antibiotic-impregnated cement spacers for the management of prosthetic joint infection. J Am Acad Orthop Surg2009;17:356–68.
11.
HoYIChanCYChengAF. In-vitro activities of aminoglycoside-aminocyclitols against mycobacteria. J Antimicrob Chemother1997;40:27–32.
12.
HendriksJGNeutDvan HornJRvan der MeiHCBusscherHJ. The release of gentamicin from acrylic bone cements in a simulated prosthesis-related interfacial gap. J Biomed Mater Res B Appl Biomater2003;64:1–5.