The usual complications of total knee arthroplasty include thrombo-embolism, infection, and loosening. We report an unusual and potentially serious complication of an intramedullary guide lodging within the femoral canal during the procedure. Considering the risk of fracture and additional exposure, the guide was not removed and was cut in situ. The rest of the operation was completed successfully and the patient made an uneventfully recovery.
KurtzSMowatFOngKChanNLauEHalpernM. Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am2005;87:1487–97.
2.
CaillouetteJTAnzelSH. Fat embolism syndrome following the intramedullary alignment guide in total knee arthroplasty. Clin Orthop Relat Res1990;251:198–9.
3.
FahmyNRChandlerHPDanylchukKMattaEBSunderNSiliskiJM. Blood-gas and circulatory changes during total knee replacement. Role of the intramedullary alignment rod. J Bone Joint Surg Am1990;72:19–26.
4.
RautVVStoneMHWroblewskiBM. Reduction of postoperative blood loss after press-fit condylar knee arthroplasty with use of a femoral intramedullary plug. J Bone Joint Surg Am1993;75:1356–7.
5.
YauWPNgTPChiuKY. Unusual complication associated with femoral intramedullary alignment guide in total knee arthroplasty. J Arthroplasty2001;16:247–9.
6.
ChanWLYenCHWongKKTsePYMakKH. Breakage of intramedullary femoral guide rod during total knee arthroplasty: A case report. J Orthop Surg (Hong Kong)2006;14:96–8.
7.
BrysDALombardiAVJrMalloryTHVaughnBK. A comparison of intramedullary and extramedullary alignment systems for tibial component placement in total knee arthroplasty. Clin Orthop Relat Res1991;263:175–9.
8.
CatesHERitterMAKeatingEMFarisPM. Intramedullary versus extramedullary femoral alignment systems in total knee replacement. Clin Orthop Relat Res1993;286:32–9.
9.
EnghGAPetersenTL. Comparative experience with intramedullary and extramedullary alignment in total knee arthroplasty. J Arthroplasty1990;5:1–8.
10.
TeterKEBregmanDColwellCWJr. The efficacy of intramedullary femoral alignment in total knee replacement. Clin Orthop Relat Res1995;321:117–21.
11.
BathisHPerlickLTingartMLuringCZurakowskiDGrifkaJ. Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br2004;86:682–7.
12.
VaidyaSVRanawatCSAroojisALaudNS. Anthropometric measurements to design total knee prostheses for the Indian population. J Arthroplasty2000;15:79–85.
13.
FangDChiuKYRemediosIDYinQ. Osteometry of the Chinese proximal femur. J Orthop Surg (Hong Kong)1996;4:41–5.