Acquired radial club hand caused by infection has been reported occasionally. We report a rare case of acquired radial club hand with an associated septic dislocation of the elbow, primarily caused by compartment syndrome following venous cannulation. The deformity and instability were treated with distraction using an external fixator followed by a centralisation procedure. At the 2-year follow-up the appearance and functions of the left forearm had improved considerably and the wrist was stable. There was no deterioration in ulnar growth.
DreyfussU. Acquired club hand–a case report. Hand1977;9:268–71.
2.
HaqueIU. The production of a one-bone forearm as a salvage procedure after haematogenous osteomyelitis. A case report. J Bone Joint Surg Br1982;64:454–5.
3.
StraussbergRHarelLBar-SeverZAmirJ. Radial osteomyelitis as a complication of venous cannulation. Arch Dis Child2001;85:408–10.
4.
KesslerI. Centralisation of the radial club hand by gradual distraction. J Hand Surg Br1989;14:37–42.
5.
PickfordMASchekerLR. Distraction lengthening of the ulna in radial club hand using Ilizarov technique. J Hand Surg Br1998;23:186–91.
6.
BoraFWJrNicholsonJTCheemaHM. Radial meromelia. The deformity and its treatment. J Bone Joint Surg Am1970;52:966–79.
7.
ManskePRMcCarrollHRJrSwansonK. Centralization of the radial club hand: An ulnar surgical approach. J Hand Surg Am1981;6:423–33.
8.
LambDW. Radial club hand. A continuing study of sixty-eight patients with one hundred and seventeen club hands. J Bone Joint Surg Am1977;59:1–13.