Numerous techniques have been described for internal fixation of displaced intra-articular fractures of the phalanges, including percutaneous pinning, microplating, interosseous wiring and tension banding techniques. One method, described by Rayhack and Bottke, is a modified tension banding method using a K-wire and a stainless steel wire. Although this technique has been found to be very useful, certain complications have led to the development of a modification of this technique.
RayhackJM, BottkeCA. Intraosseous compression wiring of displaced articular condylar fractures.J Hand Surg1990; 15A: 370–3.
2.
GreeneTL, NoellertRC, BelsoleRJ, SimpsonLA. Composite wiring of metacarpal and phalangeal fractures.J Hand Surg1989; 14A: 665–9.
3.
HastingsH., CarrollC.. Treatment of closed articular fractures of the metacarpophalangeal and proximal interphalangeal joints.Hand Clin1988; 4: 503–27.
4.
JabaleyME, FreelandAE. Rigid internal fixation in the hand: 104 cases.Plast Reconstr Surg1986; 77: 288–98.
5.
MarglesSW. Intraarticular fractures of the metacarpophalangeal and proximal interphalangeal joints.Hand Clin1988; 4: 67–74.
6.
FreelandAE, BehoistLA. Open reduction and internal fixation for fractures at the proximal interphalangeal joint.Hand Clin1994; 10: 239–50.