Orbital fractures are common fractures of the midface. As such, numerous techniques and materials exist for the repair of this region, each with inherent advantages and disadvantages. But does the ideal implant material exist? Should we stop and simply use readily available materials, or should the cycle of need and discovery continue? a comprehensive review of materials used in orbital reconstruction and possible new directions in orbital floor reconstruction are presented.
CourtneyD.J., ThomasS., WhitfieldP.H.. Isolated orbital blowout fractures: Survey and review.Br J Oral Maxillofac Surg2000; 38: 496503.
2.
BurnstineM.A.. Clinical recommendations for the repair of isolated orbital floor fractures: An evidence-based analysis.Ophthalmology2002; 109: 120713.
3.
BahrW., BagambisaF., Stom, SchlegelG., SchilliW.. Comparison of transcutaneous incisions used for the exposure of the infraorbital rim and orbital floor: A retrospective study.Plast Reconstr Surg1992; 90: 58591.
4.
LeeM.J., KangY.S., YangJ.Y., Lee doY., ChungY.Y., RohrichR.J.. Endoscopic transnasal approach for the treatment of medial orbital blow-out fracture: A technique for controlling the fractrured wall with a balloon catheter and Merocel.Plast Reconstr Surg2002; 110: 41728.
5.
ChowdhuryK., KrauseG.F.. Selection of materials for orbital floor reconstruction.Arch Otolaryngol Head Neck Surg1998; 124: 1398401.
KlineR.M.Jr, WolfeS.A.. Complications associated with the harvesting of cranial bone grafts.Plast Reconstr Surg1995; 95: 520.
8.
IatrouI., Theologie-LygidakisN., AngelopoulosA.. Use of membrane and bone grafts in the reconstruction of orbital fractures.Oral Surg Oral Med Oral Pathol Oral Radiol Endod2001; 91: 2816.
9.
JohnsonE.P., RaftopoulosI.. In situ splitting of a rib graft for reconstruction of the orbital floor.Plast Reconstr Surg1999; 103: 170911.
10.
MintzS.M., EttingerA., SchmakelT., GleasonM.J.. Contralateral coronoid process bone grafts for orbital floor reconstruction: An anatomic and clinical study.J Oral Maxillofac Surg1998; 56: 11405.
11.
KakibuchiM., FukudaK., YamadaN.. A simple method for harvesting a thin iliac bone graft for reconstruction of the orbital wall.Plast Reconstr Surg2003; 111: 9612.
12.
OzakiW., BuchmanS.R.. Volume maintenance of onlay bone grafts in the craniofacial skeleton: Micro-architecture versus embryologic origin.Plast Reconstruc Surg1998; 102: 2919.
13.
GlassmanR.D., MansonP.N., VanderkolkC.A.. Rigid fixation of internal orbital fractures.Plast Reconstr Surg1990; 86: 110311.
SullivanP.K., RosensteinD.A., HolmesR.E., CraigD., MansonP.N.. Bone graft reconstruction of the monkey orbital floor with iliac grafts and titanium mesh plates: A histometric study.Plast Reconstr Surg1993; 91: 76977.
16.
EllisE3rd, TanY.. Assessment of internal orbital reconstructions for pure blowout fractures: Cranial bone grafts versus titanium mesh.J Oral Maxillofac Surg2003; 61: 44253.
17.
LinK.Y., BartlettS.P., YaremchukM.J., FallonM., GrossmanR.F., WhitakerL.A.. The effect of rigid fixation on the survival of onlay bone grafts: An experimental study.Plast Reconstr Surg1990; 86: 44956.
18.
PhilipsJ.H., RahnB.A.. Fixation effects on membranous and endochondral onlay bone graft revascularization and bone deposition.Plast Reconstr Surg1990; 85: 8917.
19.
ZinsJ.E., WhitakerL.A.. Membranous versus endochondral bone: Implications for craniofacial reconstruction.Plast Reconstr Surg1983; 72: 77885.
20.
KrausM., GatotA., FlissD.. Repair of traumatic inferior orbital wall defects with nasoseptal cartilage.J Oral Maxillofac Surg2001; 59: 1397401.
21.
ConstantianM.B.. Use of auricular cartilage in orbital floor reconstruction.Plast Reconstr Surg1982; 69: 9515.
22.
DostP.. [Orbital floor reconstruction with autologous periosteum transplant].Laryngorhinootologie1996; 75: 578.
23.
CelikozB., DumanH., SelmanpakogluN.. Reconstruction of the orbital floor with lyophilized tensor fascia lata.J Oral Maxillofac Surg1997; 55: 2404.
24.
NeigelJ.M., RuzickaP.O.. Use of demineralised bone implants in orbital and craniofacial reconstruction and a review of the literature.Ophthal Plast Reconstr Surg1996; 12: 10820.
25.
WaiteP.D., ClantonJ.T.. Orbital floor reconstruction with lyophilized dura.J Oral Maxillofac Surg1988; 46: 72730.
26.
GuerraM.F., PerezJ.S., Rodriguez-CampoJ.F., GiasL.N.. Reconstruction of orbital fractures with dehydrated human dura matter.J Oral Maxillofac Surg2000; 58: 13616.
27.
BevivinoJ.R., NguyenP.N., YenL.J.. Reconstruction of traumatic orbital floor defects using irradiated cartilage homografts.Ann Plast Surg1994; 33: 327.
28.
ChenJ.M., ZinggM., LaedrachK., RavehJ.. Early surgical intervention for orbital floor fractures: A clinical evaluation of lyophilized dura and cartilage reconstruction.J Oral Maxillofac Surg1992; 50: 93541.
29.
MoraxS., HurbliT., SmidaR.. [Bovine heterologous bone graft in orbital surgery].Ann Chir Plast Esthet1993; 38: 44550.
30.
CampbellD.G., LiP.. Sterilization of HIV with irradiation: Relevance to infected bone allografts.Aust N Z J Surg1999; 69: 51721.
31.
AhoA.J., HirnM., AroH.T., HeikkilaJ.T., MeurmanO.. Bone bank service in Finland. Experience of bacteriologic, serologic and clinical results of the Turku Bone Bank 1972-1995.Acta Orthop Scand1998; 69: 55965.
32.
NakumuraY., AsoE., YanagawaH.. Relative risk of Creutzfeldt-Jakob disease with cadaveric dura transplantation in Japan.Neurology1999; 53: 21820.
33.
Munoz GuerraM.F.. Human dura matter and Creutzfeldt-Jakob Disease.J Oral Maxillofac Surg2001; 59: 595.
34.
TaguchiF., TamaiY., UchidaK.. Proposal for a procedure for complete inactivation of the Creutzfeldt-Jakob disease agent.Arch Virol1991; 119: 297301. (Erratum in: 1992;122:411)
35.
HuagR.H., NuveenE., BredbennerT.. An evaluation of the support provided by common internal orbital reconstruction materials.J Oral Maxillofac Surg1999; 57: 56470.
SchmidtB.L., LeeC., YoungD.M., O'BrienJ.. Infraorbital squamous epthilial cyst: An unusual complication of Silastic implantation.J Craniofac Surg1998; 9: 4525.
38.
LaxenaireA., LevyJ., BlanchardP., LerondeauJ.C., TesnierF., SchefferP.. [Complications of silastic implants used in orbital repair].Rev Stomatol Chir Maxillofac1997; 98(Suppl 1):969.
39.
KlisovicD.D., KatzS.E., LubowM.. The wayward implant: Orbital silicone plate extrusion associated with squamous epithelial downgrowth and infection.Orbit2002; 21: 14954.
40.
LiuD., Al-SadhanY.. Orbital floor implant migration across the ethmoidal sinuses and nasal septum.Am J Ophthalmol1999; 128: 1223.
41.
MwanzaJ.C., NgoyD.K., KayembeD.L.. Reconstruction of orbital floor blow-out fractures with silicone implant.Bull Soc Belge Ophtalmol2001; 280: 5761.
42.
DoughertyW.R., WelliszT.. The natural history of alloplastic implants in orbital floor reconstruction: An animal model.J Craniofac Surg1994; 5: 2633.
43.
KinnunenI., AitasaloK., PollonenM., VarpulaM.. Reconstruction of orbital floor fractures using bioactive glass.J Craniomaxillofac Surg2000; 28: 22934.
44.
AitasaloK., KinnunenI., PalmgrenJ., VarpulaM.. Repair of orbital floor fractures with bioactive glass implants.J Oral Maxillofac Surg2001; 59: 13906.
RomanoJ.J., IliffN.T., MansonP.N.. Use of Medpor porous polyethylene implants in 140 patients with facial fractures.J Craniofac Surg1993; 4: 1427.
47.
VillarrealP.M., MonjeF., MorilloA.J., JunqueraL.M., GonzalezC., BarbonJ.J.. Porous polyethylene implants in orbital floor reconstruction.Plast Reconstr Surg2002; 109: 87787.
48.
GosainA.K., PersingJ.A.. Biomaterials in the face: Benefits and risks.J Craniofac Surg1999; 10: 40414.
49.
MackenzieD.J., AroraB., HansenJ.. Orbital floor repair with titanium mesh screen.J Carniomaxillofac Trauma1999; 5: 918.
50.
ParkH.S., KimY.K., YoonC.H.. Various applications of titanium mesh screen implant to orbital wall fractures.J Craniofac Surg2001; 12: 55560.
51.
GearA.J., LokehA., AldridgeJ.H., MiglioriM.R., BenjaminC.I., SchubertW.. Safety of titanium mesh for orbital reconstruction.Ann Plast Surg2002; 48: 19.
52.
SargentL.A., FulksK.D.. Reconstruction of internal orbit fractures with Vitallium mesh.Plast Reconstr Surg1991; 88: 318.
53.
SchubertW., GearA.J., LeeC.. Incorporation of titanium mesh in orbital and midface reconstruction.Plast Reconstr Surg2002; 110: 102232.
54.
MofidM.M., ThompsonR.C., PardoC.A., MansonP.N., Vander KolkC.A.. Biocompatibility of fixation materials in the brain.Plast Reconstr Surg1997; 100: 1422.
55.
UngersbockA., PohlerO., PerrenS.M.. Evaluation of soft tissue interface at titanium implants with different surface treatments: Experimental study on rabbits.Biomed Mater Eng1994; 4: 31725.
56.
HughesC.W., PageK., BibbR., TaylorJ., RevingtonP.. The custom-made titanium orbital floor prosthesis in reconstruction for orbital floor fractures.Br J Oral Maxillofac Surg2003; 41: 503. (Erratum in: 2003;41:209)
57.
ParkinJ.L., StevensM.H., StringhamJ.C.. Absorbable gelatin film verses silicone rubber sheeting in orbital fracture treatment.Laryngoscope1987; 97: 13.
58.
MermerR.W., OrbanREJr. Repair of orbital floor fractures with absorbable gelatin film.J Craniomaxillofac Trauma1995; 1: 304.
59.
HattonP.V., WalshJ., BrookI.M.. The response of cultured bone cells to resorbable polyglycolic acid and silicone membranes for use in orbital floor fracture repair.Clin Mater1994; 17: 7180.
60.
BaloghC., LucasR., KraftT., BretonP., FreidelM.. [Lactic acid polymer implants in the repair of traumatic defects of the orbital floor].Rev Stomatol Chir Maxillofac2001; 102: 10914.
61.
PersonsB.L., WongG.B.. Transantral endoscopic orbital floor repair using resorbable plate.J Craniofac Surg2002; 13: 4838.
62.
HollierL.H., RogersN., BerzinE., StalS.. Resorbable mesh in the treatment of orbital floor fractures.J Craniofac Surg2001; 12: 2426.
63.
PiotrowskiW.P., Mayer-ZuchiU.. The use of polyglactin 910-polydioxanon in the treatment of defects of the orbital roof.J Oral Maxillofac Surg1999; 57: 13016.
64.
BaumannA., BurggasserG., GaussN., EwersR.. Orbital floor reconstruction with an alloplastic resorbable polydiaxanone sheet.Int J Oral Maxillofac Surg2002; 31: 36773.
65.
KontioR., SuuronenR., SalonenO., PaukkuP., KonttinenT., LindqvistC.. Effectiveness of operative treatment of internal orbital wall fracture with polydiaxanone implant.Int J Oral Maxillofac Surg2001; 30: 27885.
66.
JankS., EmshoffR., SchuchterB., StroblH., BrandlmaierI., NorerB.. Orbital floor recontruction with flexible Ethisorb patches: A retrospective long-term follow-up study.Oral Surg Oral Med Oral Pathol Oral Radiol Endod2003; 95: 1622.