Metal-on-metal (M-M) joint replacement has raised concerns about the long-term effects of metal wear debris and corrosion products. This review summarizes the current concepts in biological reactivity to metal wear particles, ions, and corrosion products. Attention is focused on Co-Cr-Mo alloy since it is the most diffused and discussed material in arthroplasty.
CrawfordR., RanawatC.S., RothmanR.H.Metal on metal: is it worth the risk?J Arthroplasty2010; 25: 1–2.
2.
CampbellP.A., WangM., AmstutzH.C., GoodmanS.B.Positive cytokine production in failed metal-on-metal total hip replacements. Acta Orthop Scand2002; 73: 506–12.
3.
WillertH.G., BuchhornG.H., FayyaziA.. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am2005; 87: 28–36.
4.
CampbellP., NelsonS., EspositoC., TakamuraK., De SmetK.Soft tissue histology around metal-on-metal hips. 55th Annual Meeting of the Orthopaedic Research Society. Las Vegas, NV, 2009.
5.
KwonY., OstlereS., McLardy-SmithP.. Metal ion levels in asymptomatic pseudotumours associated with metal-on-metal hip resurfacings. 55th Annual Meeting of the Orthopaedic Research Society. Las Vegas, NV, 2009: 44.
6.
PanditH., Glyn-JonesS., McLardy-SmithP.. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br2008; 90: 847–51.
7.
PanditH., VlychouM., WhitwellD.. Necrotic granulomatous pseudotumours in bilateral resurfacing hip arthoplasties: evidence for a type IV immune response. Virchows Arch2008; 453: 529–34.
8.
WillertH.G., BuchornG., FayaziA., LohmannC.Histopathological changes around metal-metal joints indicate delayed type hypersensitivity. Preliminary results of 14 cases. Osteologie2000; 9: 2–16.
9.
SchmalzriedT.Metal-metal bearing surfaces in hip arthroplasty. Orthopedics2009; 32(9).
10.
ThomasP., BraathenL.R., DörigM.. Increased metal allergy in patients with failed metal-on-metal hip arthroplasty and peri-implant T-lymphocytic inflammation. Allergy2009; 64: 1157–65.
11.
HuberM., ReinischG., TrettenhahnG., ZweymüllerK., LintnerF.Presence of corrosion products and hypersensitivity-associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfaces. Acta Biomater2009; 5: 172–80.
12.
SvenssonO., MathiesenE.B., ReinholtF.P., BlomgrenG.Formation of a fulminant soft-tissue pseudotumor after uncemented hip arthroplasty. A case report. J Bone Joint Surg Am1988; 70: 1238–42.
13.
CampbellP., ShimminA., WalterL., SolomonM.Metal sensitivity as a cause of groin pain in metal-on-metal hip resurfacing. J Arthroplasty2008; 23: 1080–5.
14.
De SmetK., De HaanR., CalistriA.. Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing. J Bone Joint Surg Am2008; 90(Suppl): 202–8.
15.
BowsherJ., HussainA., WilliamsP., SheltonJ.Metal-on-metal hip simulator study of increased wear particle surface area due to ‘severe’ patient activity. Proc Inst Mech Eng H.2006; 220: 279–87.
16.
DoornP.F., CampbellP.A., WorrallJ., BenyaP.D., McKellopH.A., AmstutzH.C.Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res1998; 42: 103–11.
17.
HirakawaK., BauerT.W., StulbergB.N., WildeA.H., SecicM.Characterization and comparison of wear debris from failed total hip implants of different types. J Bone Joint Surg Am1996; 78: 1235–43.
18.
CatelasI., BobynJ.D., MedleyJ.B., KrygierJ.J., ZukorD.J., HukO.L.Size, shape, and composition of wear particles from metal-metal hip simulator testing: effects of alloy and number of loading cycles. J Biomed Mater Res A2003; 67: 312–27.
19.
CatelasI., MedleyJ.B., CampbellP.A., HukO.L., BobynJ.D.Comparison of in vitro with in vivo characteristics of wear particles from metal-metal hip implants. J Biomed Mater Res B Appl Biomater2004; 70: 167–78.
20.
CaicedoM., JacobsJ.J., ReddyA., HallabN.J.Analysis of metal ion-induced DNA damage, apoptosis, and necrosis in human (Jurkat) T-cells demonstrates Ni2+ and V3+ are more toxic than other metals: Al3+, Be2+, Co2+, Cr3+, Cu2+, Fe3+, Mo5+, Nb5+, Zr2+. J Biomed Mater Res A2008; 86: 905–13.
21.
AdamM.K., ClaudeI.A., HarryE.R., ArunS.S.Human macrophage response to UHMWPE, TiAlV, CoCr, and alumina particles: Analysis of multiple cytokines using protein arrays. J Biomed Mater Res A2008; 84: 464–74.
SethiR.K., NeavynM.J., RubashH.E., ShanbhagA.S.Macrophage response to cross-linked and conventional UHMWPE. Biomaterials2003; 24: 2561–73.
24.
CampbellP.A., WangM., AmstutzH.C., GoodmanS.B.Positive cytokine production in failed metal-on-metal total hip replacements. Acta Orthopaedica2002; 73: 506–12.
SommerB., FelixR., SprecherC., LeunigM., GanzR., HofstetterW.Wear particles and surface topographies are modulators of osteoclastogenesis in vitro. J Biomed Mater Res A2005; 72: 67–76.
29.
CaicedoM.S., DesaiR., McAllisterK., ReddyA., JacobsJ.J., HallabN.J.Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: a novel mechanism for implant debris reactivity. J Orthop Res2009; 27: 847–54.
30.
PapageorgiouI., BrownC., SchinsR.. The effect of nano-and micron-sized particles of cobalt-chromium alloy on human fibroblasts in vitro. Biomaterials2007; 28: 2946–58.
31.
KwonY.M., XiaZ., Glyn-JonesS., BeardD., GillH.S., MurrayD.W.Dose-dependent cytotoxicity of clinically relevant cobalt nanoparticles and ions on macrophages in vitro. Biomed Mater2009; 4: 25018.
32.
ChithraniB.D., ChanW.C.W.Elucidating the mechanism of cellular uptake and removal of protein-coated gold nanoparticles of different sizes and shapes. Nano Lett2007; 7: 1542–50.
33.
GrattonS.E.A., RoppP.A., PohlhausP.D.. The effect of particle design on cellular internalization pathways. Proc Natl Acad Sc USA2008; 105: 11613–8.
34.
SinghN., ManshianB., JenkinsG.J.S.. Nano Genotoxicology: the DNA damaging potential of engineered nanomaterials. Biomaterials2009; 30: 3891–914.
35.
LewisA.C., LadonD., HeardP.J., PetoL., LearmonthI.The role of the surface chemistry of CoCr alloy particles in the phagocytosis and DNA damage of fibroblast cells. J Biomed Mater Res A2007; 82: 363–72.
36.
LewisA.C., HeardP.J.The effects of calcium phosphate deposition upon corrosion of CoCr alloys and the potential for implant failure. J Biomed Mater Res A2005; 75: 365–73.
37.
ThieleL., MerkleH.P., WalterE.Phagocytosis and phagosomal fate of surface-modified microparticles in dendritic cells and macrophages. Pharm Res2003; 20: 221–8.
38.
ChithraniB.D., GhazaniA.A., ChanW.C.W.Determining the size and shape dependence of gold nanoparticle uptake into mammalian cells. Nano Lett2006; 6: 662–8.
39.
RejmanJ., OberleV., ZuhornI.S., HoekstraD.Size-dependent internalization of particles via the pathways of clathrin-and caveolae-mediated endocytosis. Biochem J2004; 377: 159–69.
40.
MilosevI., StrehblowH.H.The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solution. Electrochimica Acta2003; 48: 2767–74.
JacobsJ.J.Current concepts review - corrosion of metal orthopaedic implants. J Bone Joint Surg Am1998; 80: 268–82.
44.
HodgsonA.W.E., KurzS., VirtanenS., FervelV., OlssonC.O.A., MischlerS.Passive and transpassive behaviour of CoCrMo in simulated biological solutions. Electrochimica Acta2004; 49: 2167–78.
45.
HodgsonA.W., MischlerS., Von RechenbergB., VirtanenS.An analysis of the in vivo deterioration of Co-Cr-Mo implants through wear and corrosion. Proc Inst Mech Eng H2007; 221: 291–303.
46.
GrublA., MarkerM., BrodnerW.. Long-term follow-up of metal-on-metal total hip replacement. J Orthop Res2007; 25: 841–8.
47.
RasquinhaV.J., RanawatC.S., WeiskopfJ., RodriguezJ.A., SkiporA.K., JacobsJ.J.Serum metal levels and bearing surfaces in total hip arthroplasty. J Arthroplasty2006; 21(Suppl): 47–52.
48.
KwonY., XiaZ., Glyn-JonesS., BeardD., GillH.S., MurrayD.W.Dose-dependent cytotoxicity of clinically relevant cobalt nanoparticles and ions on macrophages in vitro. Biomed Mater2009: 25018.
49.
YamamotoA., HonmaR., SumitaM.Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblastic cells. J Biomed Mater Res1998; 39: 331–40.
50.
GranchiD., CenniE., CiapettiG.. Cell death induced by metal ions: necrosis or apoptosis?J Mater Sci Mater Med1998; 9: 31–7.
51.
CatelasI., PetitA., ZukorD.J., AntoniouJ., HukO.L.TNF-alpha secretion and macrophage mortality induced by cobalt and chromium ions in vitro-qualitative analysis of apoptosis. Biomaterials2003; 24: 383–91.
52.
GermainM.A., HattonA., WilliamsS.. Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro. Biomaterials2003; 24: 469–79.
53.
BrownC., FisherJ., InghamE.Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses. Proc Inst Mech Eng H2006; 220: 355–69.
54.
GranchiD., CiapettiG., SavarinoL., CavedagnaD., DonatiM.E., PizzoferratoA.Assessment of metal extract toxicity on human lymphocytes cultured in vitro. J Biomed Mater Res1996; 31: 183–91.
55.
PetitA., MwaleF., ZukorD.J., CatelasI., AntoniouJ., HukO.L.Effect of cobalt and chromium ions on bcl-2, bax, caspase-3, and caspase-8 expression in human U937 macrophages. Biomaterials2004; 25: 2013–8.
56.
DaleyB., DohertyA.T., FairmanB., CaseC.P.Wear debris from hip or knee replacements causes chromosomal damage in human cells in tissue culture. J Bone Joint Surg Br2004; 86: 598–606.
57.
LadonD., DohertyA., NewsonR., TurnerJ., BhamraM., CaseC.P.Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplasty2004; 19(Suppl): 78–83.
58.
DaviesA.P., SoodA., LewisA.C., NewsonR., LearmonthI.D., CaseC.P.Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty. J Bone Joint Surg Br2005; 87: 1439–44.