Three Tesla imaging of the pediatric brain is feasible without significant SAR limitations and provides improved diagnostic information relative to 1.5 T for MRA, thin section T1 and T2 images, susceptibility scans, and conspicuity of contrast enhancement.
GonenOGruberSLiBS: Multivoxel 3D proton spectroscopy in the brain at 1.5 T versus 3.0 T: Signal-to-noise ratio and resolution comparison. Am J Neuroradiol22: 1727–1731, 2001.
2.
BarkerPBHearshenDOBoskaMD: Single-voxel proton MRS of the human brain at 1.5 T and 3.0 T. Magn Reson Med45: 765–9, 2001.
3.
KrugerGKastrupAGloverGH: Neuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation-sensitive magnetic resonance imaging. Magn Reson Med45: 595–604, 2001.
4.
ThulbornKR: Clinical rationale for very-high-field (3.0 Tesla) functional magnetic resonance imaging. Top Magn Reson Imag10: 37–50, 1999.
5.
HunscheSMoseleyMEStoeterP: Diffusion-tensor MR imaging at 1.5 and 3.0 T: Initial observations. Radiol221: 550–56, 2001.
6.
BernsteinMAHustonJLinCGibbs: High-resolution intracranial and cervical MRA at 3.0 T: Technical considerations and initial experience. Magn Reson Med46: 955–62, 2001.
7.
CampeauNGHustonJBernsteinMA: Magnetic resonance angiography at 3.0 T: Initial clinical experience. Top Magn Reson Imag12: 183–204, 2001.
8.
ThomasSDAl-KwifiOEmeryDJ: Application of magnetization transfer at 3.0 T in three-dimensional time-of-flight magnetic resonance angiography of the intracranial arteries. J Magn Reson Imaging15: 479–83, 2002.
9.
Al-KwifiOEmeryDJWilmanAH: Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries. Magn Reson Imaging20: 181–87, 2002.
10.
YangJJHillMDMorrishWF: Comparison of pre-and postcontrast 3D time-of-flight MR angiography for the evaluation of distal intracranial branch occlusions in acute ischemic stroke. Am J Neuroradiol23: 557–67, 2002.
11.
US Department of Health and Human Services, Food and Drug Administration, Centre for Devices and Radiological Health. Guidance for the submisson of pre-market notifications for magnetic resonance diagnostic devices. Washington, DC1998.
12.
FelmleeJPBersteinMAHustonJ: Analysis of RF Heating at 3.0 T. Proc Intl Soc Mag Reson Med2000; 8: 8, 2000.
13.
FrayneRGoodyearBGDickhoffP: Magnetic resonance imaging at 3.0 Tesla: Challenges and advantages in clinical neurological imaging. Invest Radiol38: 385–402, 2003.
14.
WansapuraJPHollandSKDunnRS: NMR relaxation times in the human brain at 3.0 T. JMRI9: 531–538, 1999.
15.
LinCBernsteinMAHustonJ: In vivo and in vitro measurements of T1 at 3.0 T. Proc Intl Soc Magn Reson Med9: 1685, 2001.
16.
HennemeyerCTWicklowKFeinbergDA: In vitro evaluation of platinum Guglielmi detachable coils at 3.0 T with a porcine model: Safety issues and artifacts. Radiol219: 732–737, 2001.
17.
ShellockFG: Biomedical implants and devices; Assessment of magnetic field interactions with a 3.0-Tesla MR system. J Magn Reson Imaging16: 721–32, 2002.
18.
ShellockFGCruesJV: 3rd. MR safety and the American College of Radiology White Paper. AJR178: 1349–1352, 2002.