WeissmanC.Measuring oxygen uptake in the clinical setting. In: Bryan-BrownCW, AyresSM, eds. Oxygen transport and utilization. Fullerton CA: Society of Critical Care Medicine, 1987:25–64.
2.
EliaM, LiveseyG.Theory and validity of indirect calorimetry during net lipid synthesis. Am J Clin Nutr1988;47:591–607.
3.
FerranniniE.The theoretical bases of indirect calorimetry: a review. Metabolism1988;37:287–301.
4.
KemperMA. Indirect calorimetry equipment and practical considerations of measurement. In: WeissmanC, ed. Problems in respiratory care: nutrition and respiratory disease. Philadelphia: JB Lippincott, 1989:2–479-490.
5.
BransonRD. The measurement of energy expenditure: instrumentation, practical considerations, and clinical application. Respir Care1990;35:640–659.
6.
McDonaldNJ, LavelleP, GallacherWN, HarpinRP. Use of the oxygen cost of breathing as an index of weaning ability from mechanical ventilation. Intensive Care Med1988;14:50–54.
7.
LewisWD, ChwalsW, BenottiPN, LakshmanK, O'DonnellC, BlackburnGL, Bistrian et al. Bedside assessment of the work of breathing. Crit Care Med1988;16:117–122.
8.
ShikoraSA, BistrianBR, BorlaseBC, BlackburnGL, StoneMD, BenottiPN. Work of breathing: reliable predictor of weaning and extubation. Crit Care Med1990;18:157–162.
9.
DanekSJ, LynchJP, WegJG, DantzkerDR. The dependence of oxygen uptake on oxygen delivery in the adult respiratory distress syndrome. Am Rev Respir Dis1980;122:387–395.
10.
KaufmanBS, RackowEC, FalkJL. The relationship between oxygen delivery and consumption during fluid resuscitation of hypovolemic and septic shock. Chest1984;85:336–340.
11.
deV WeirJB. New methods for calculating metabolic rate with special reference to protein metabolism. J Physiol1949;109:1–9.
12.
DalyJM, HeymsfieldSB, HeadCA, HarveyLP, NixonDW, KatzeffH, GrossmanGD. Human energy requirements: overestimation by widely used prediction equation. Am J Clin Nutr1985;42:1170–1174.
NixonDW, KutnerM, HeymsfieldS, FoltzAT, CartyC, SeitzS, . Resting energy expenditure in lung and colon cancer. Metabolism1988;37:1059–1064.
15.
BlumbergA, KellerG.Oxygen consumption during maintenance hemodialysis. Nephron1979;23:276–281.
16.
LongCL. Energy balance and carbohydrate metabolism in infection and sepsis. Am J Clin Nutr1977;30:1301–1310.
17.
CurreriPW, RichmondD, MarvinJ, BaxterCR. Dietary requirements of patients with major burns. J Am Diet Assoc1974;65:415–417.
18.
CliftonGL, RobertsonCS, GrossmanRG, HodgeS, FoltzR, GarzaC.The metabolic response to severe head injury. J Neurosurg1984;60:687–696.
19.
MullenJL. Consequences of malnutrition in the surgical patient. Surg Clin North Am1981;61:465–487.
20.
WeissmanC, KemperMC, AskanaziJ, HymanAl, KinneyJM. Resting metabolic rate of the critically ill patient: measured versus predicted. Anesthesiology1986;64:673–679.
21.
BransonRD, HurstJM, WarnerBW, BowerRH, AritaA.Measured versus predicted energy expenditure in mechanically ventilated patients with chronic obstructive pulmonary disease. Respir Care1987;32:748–752.
22.
SchaneJ, GoedeM, SilversteinP.Comparison of energy expenditure measurement techniques in severely burned patients. J Burn Care Rehabil1987;8:366–370.
23.
HunterDC, JaksicT, LewisD, BenottiPN, BlackburnGL, BistrianBR. Resting energy expenditure in the critically ill: estimations versus measurement. Br J Surg1988;75:875–878.
24.
MooreJA, AngelilloVA. Equations for the prediction of resting energy expenditure in chronic obstructive lung disease. Chest1988;94:1260–1263.
25.
CliftonGL, RobertsonCS, ChoiSC. Assessment of nutritional requirements of head-injured patients. J Neurosurg1986;64:895–901.
26.
FosterGD, KnoxLS, DempseyDT, MullenJL. Caloric requirements in total parenteral nutrition. J Am Coll Nutr1987;6:231–253.
27.
AskanaziJ, NordenstromJ, RosenbaumSH, ElwynDH, HymanAI, CarpentierYA, KinneyJM. Nutrition for the patient with respiratory failure: glucose vs fat. Anesthesiology1981;54:373–377.
28.
MohseninV, FerrantiR, LokeJS. Nutrition for the respiratory insufficient patient. Eur Respir J Suppl1989;7:663S–665S.
29.
AskanaziJ, RosenbaumSH, HymanAI, SilverbergPA, Milic-EmiliJ, KinneyJM. Respiratory changes induced by the large glucose loads of total parenteral nutrition. JAMA1980;243:1444–1447.
30.
CovelliHD, BalckJW, OlsenMS, BeekmanJF. Respiratory failure precipitated by high carbohydrate loads. Ann Intern Med1981;95:579–581.
31.
DarkDS, PingletonSK, KerbyGR. Hypercapnia during weaning: a complication of nutritional support. Chest1985;88:141–143.
32.
AngelilloVA, BediS, DurfeeD, DahlJ, PattersonAJ, O'DonohueWJJr. Effects of low and high carbohydrate feedings in ambulatory patients with chronic obstructive pulmonary disease and chronic hypercapnia. Ann Intern Med1985;103:883–885.
33.
LiveseyG, EliaM.Estimation of energy expenditure, net carbohydrate utilization, and net fat oxidation and synthesis by indirect calorimetry: evaluation of errors with special reference to the detailed composition of fuels. Am J Clin Nutr1988;47:608–628.
34.
EliaM, LiveseyG.Theory and validity of indirect calorimetry during net lipid synthesis. Am J Clin Nutr1988;47:591–607.
35.
BurszteinS, SapharS, SingerP, ElwynDH, . A mathematical analysis of indirect calorimetry measurements in acutely ill patients. Am J Clin Nutr1989;50:227–230.
36.
LacyJ, OrrM, BransonRD, BowerRH. Protocol for the use of indirect calorimetry to determine energy requirements of patients requiring nutritional support (abstract). 14th Clinical Proceedings of American Society of Parenteral and Enteral Nutrition, 1989:439.
37.
De CampoT, CivettaJM. The effect of short term discontinuation of high-level PEEP in patients with acute respiratory failure. Crit Care Med1979;7:47–49.
38.
CraigKC, BensonMS, PiersonDJ. Prevention of arterial oxygen desaturation during closed-airway endotracheal suction: effect of ventilator mode. Respir Care1984;29(10):1013–1018.
39.
RaurichJM, IbanezJ, MarseP.Validation of a new closed circuit indirect calorimetry method compared with the open Douglas bag method. Intensive Care Med1989;15:274–278.
40.
BransonRD, HurstJM, DavisKJr, PulsfortR.A laboratory evaluation of the Biergy VVR calorimeter. Respir Care1988;33:341–347.
41.
KepplerT, DechertRE, ArnoldiDK, FiliusR, BartlettRH. Evaluations of the Waters MRM-6000 and Biergy VVR closed-circuit indirect calorimeters. Respir Care1989;34:28–35.
42.
WeissmanC, KemperM, HymanAI. Variation in the resting metabolic rate of the mechanically ventilated critically ill patients. Anesth Analg1989;68:457–461.
43.
WeissmanC, KemperMC, DamaskMC, AskanaziJ, HymanAI, KinneyJM. The effect of routine intensive care interactions on metabolic rate. Chest1984;86:815–818.
44.
FeenstraBWA, van LanschotJJB, VermeijCG, BruiningHA. Artifacts in the assessment of metabolic gas exchange. Intensive Care Med1986;12:312–316.
45.
BishopMJ, BensonMS, PiersonDJ. Carbon dioxide excretion via bronchopleural fistulas in adult respiratory distress syndrome. Chest1987;91:400–402.
46.
BrowningJA, LinbergSE, TurneySZ, ChodoffP.The effects of a fluctuating FIO2 on metabolic measurements in mechanically ventilated patients. Crit Care Med1982;10:82–85.
47.
UltmanJS, BurszteinS.Analysis of error in the determination of respiratory gas exchange at varying FIO2. J Appl Physiol1981;50:210–216.
48.
HeadCA, GrossmanGD, JordanJC, HepplerEL, HeymsfieldSB. A valve system for the accurate measurement of energy expenditure in mechanically ventilated patients. Respir Care1985;30:969–973.
49.
NelsonLD, AndersonHB, GarciaH.Clinical validation of a new metabolic monitor suitable for use in critically ill patients. Crit Care Med1987;15:951–957.
50.
NortonAC. Accuracy in pulmonary measurement. Respir Care1979;24:131–137.
51.
RasanenJ.Continuous breathing circuit flow and tracheal tube cuff leak: sources of error during pediatric indirect calorimetry. Crit Care Med1992;20(9):1335–1340.
52.
DamaskMC, WeissmanC, AskanaziJ, HymanAI, RosenbaumSH, KinneyJM. A systematic method for validation of gas exchange measurements. Anesthesiology1982;57:213–218.
53.
NunnJF, MakitaK, RoystonB.Validation of oxygen consumption measurements during artificial ventilation. J Appl Physiol1989;67:2129–2134.
54.
MakitaK, NunnJF, RoystonB.Evaluation of metabolic measuring instruments for use in critically ill patients. Crit Care Med1990;18:638–644.
55.
TakalaJ, KeinanenO, VaisanenP, KariA.Measurement of gas exchange in intensive care: laboratory and clinical validation of a new device. Crit Care Med1989;17:1041–1047.
56.
BransonRD, HurstJM, DavisKJr, BowerRH. Comparison of open circuit and closed circuit methods for measuring oxygen consumption (abstract). American Society of Parenteral and Enteral Nutrition, Miami FL, 1989.
57.
Centers for Disease Control. Update: Universal Precautions for prevention of transmission of human immunodeficiency virus, hepatitis B, and other bloodborne pathogens in health care settings. MMWR1988;37(24):377–382,387-388.