KimballWR, LeithDE, RobinsAG. Dynamic hyperinflation and ventilator dependence in chronic obstructive pulmonary disease. Am Rev Respir Dis1982;126:991–995.
2.
MacklemPT. Hyperinflation (editorial). Am Rev Respir Dis1984;129:1–2.
3.
PepePE, MariniJJ. Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction: the auto-PEEP effect. Am Rev Respir Dis1982;126:166–170.
SmithTC, MariniJJ. Impact of PEEP on lung mechanics and work of breathing in severe airflow obstruction. The effect of PEEP on auto-PEEP. J Appl Physiol1988;65(4):1488–1499.
6.
PetrofBJ, LegareM, GoldbergP, Milic-EmiliJ, GottfriedSB. Continuous positive airway pressure reduces work of breathing and dyspnea during weaning from mechanical venitlation in severe chronic obstructive pulmonary disease. Am Rev Respir Dis1990;141:281–289.
7.
HoffmanRA, ErshowskyP, KriegerBP. Determination of auto-PEEP during spontaneous and controlled ventilation by monitoring changes in end-expiratory thoracic gas volume. Chest1989;96(3):613–616.
8.
RossiA, GottfriedSB, ZocchiL, higgsBD, LennoxS, CalverleyPM, . Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation: the effect of intrinsic positive end-expiratory pressure. Am Rev Respir Dis1985;131:672–677.
9.
RogersPL, SchlichtigR, MiroA, PinskyM.Auto-PEEP during CPR: an "occult" cause of electromechanical dissocation?Chest1991;99:492–493.
10.
TuxenDV, LaneS.The effects of ventilatory pattern on hyperinflation, airway pressures, and circulation in mechanical ventilation of patients with severe air-flow obstruction. Am Rev Respir Dis1987;136:872–879.
11.
StalcupSA, MellinsRB. Mechanical forces producing pulmonary edema in acute asthma. N Engl J Med1977;297(11):592–596.
12.
MartinJ, PowellE, ShoreS, EmrichJ, EngelLA. The role of respiratory muscles in the hyperinflation of bronchial asthma. Am Rev Respir Dis1980;121:441–447.
13.
LemaireF, TeboulJL, CinottiL, GiottoG, AbroukF, StegG, . Acute left ventricular dysfunction during unsuccessful weaning from mechanical ventilation. Anesthesiology1988;69:171–179.
14.
OtisAB, FennWO, RahnH.Mechanics of breathing in man. J Appl Physiol1950;2:592–607.
15.
RoussosCS, MacklemPT. Diaphragmatic fatigue in man. J Appl Physiol1977;43:189–197.
16.
MariniJJ. Should PEEP be used in airflow obstruction? (editorial). Am Rev Respir Dis1989;140(1):1–3.
17.
MariniJJ, CrookePS3rd, TruwitJD. Determinants and limits of pressure-preset ventilation: a mathematical model of pressure control. J Appl Physiol1989;67 (3):1081–1092.
18.
GayPC, RodarteJR, HubmayrRD. The effects of positive expiratory pressure on isovolume flow and dynamic hyperinflation in patients receiving mechanical ventilation. Am Rev Respir Dis1989;139:621–626.
19.
TobinMJ, LodatoRF. PEEP, auto-PEEP, and waterfalls (editorial). Chest1989;96(3):449–451.
20.
PermuttS, Bromberger-BarneaB, BaneHN. Alveolar pressure, pulmonary venous pressure, and the vascular waterfall. Med Thorac1962;19:239–260.
21.
SmithTC, MariniJJ, LambVJ. The inspiratory threshold load resulting from air trapping during mechanical ventilation (abstract). Am Rev Respir Dis1987;135(4, Part 2):A52.
22.
DownsJB, KleinEFJr, DesautelsD, ModellJH, KirbyRR. Intermittent mandatory ventilation: a new approach to weaning patients from mechanical ventilators. Chest1973;64:331–335.
23.
MacIntyreNR. Respiratory function during pressure support ventilation. Chest1986;89:677–683.
24.
BrochardL, PluskwaF, LemaireF.Improved efficacy of spontaneous breathing with inspiratory pressure support. Am Rev Respir Dis1987;136:411–415.
25.
MariniJJ, CappsJS, CulverBH. The inspiratory work of breathing during assisted mechanical ventilation. Chest1985;87(5):612–618.
26.
MariniJJ, RodriguezRM, LambV.The inspiratory workload of patient-initiated mechanical ventilation. Am Rev Respir Dis1986;134:902–909.
27.
MariniJJ, SmithTC, LambVJ. External work output and force generation during synchronized intermittent mechanical ventilation: effect of machine assistance on breathing effort. Am Rev Respir Dis1988;138:1169–1179.
28.
ImsandC, FeihlF, PerretC, FittingJW. Effect of assisted ventilation in SIMV mode on inspiratory muscle activity (abstract). Am Rev Respir Dis1991;143(4, Part 2):A603.
29.
MariniJJ. Minimizing breathing effort during mechanical ventilation. In: LeMaireF, ZapolWM, eds. Acute respiratory failure. New York: Marcel Dekker, 1990:163–194.
30.
AmatoMBP, BarbasCSV, BonassaJ, SaldivaPHN, ZinWA, de CarvalhoCR. Volume-assured pressure support ventilaton (VAPSV): a new approach for reducing muscle workload during acute respiratory failure. Chest1992;102:1225–1234.
31.
HyattRE. Expiratory flow limitation. J Appl Physiol1983;55(1, Part 1):1–7.
32.
YounesM.Proportional assist ventilation and pressure support ventilation: similarities and differences. In: MariniJJ, RoussosC, eds. Ventilatory failure. Berlin: Springer-Verlag, 1991:361–380.
33.
YounesM.Proportional assist ventilation: a new approach to ventilatory support theory. Am Rev Respir Dis1992;145:114–120.
34.
MariniJJ. Lung mechanics in ARDS-recent conceptual advances and implications for management. In: WiedemannHP, MatthayMA, MatthayRA, eds. Clinics in chest medicine. Philadelphia: WB Saunders, 1990:673–690.
35.
GattinoniL, PesentiA, BombinoM, BaglioniS, RivoltaS, RossiF, . Relationships between lung computed tomographic density, gas exchange, and PEEP in acute respiratory failure. Anesthesiology1988;69:824–832.
36.
MaunderRJ, ShumanWP, McHughJW, MarglinSI, ButlerJ.Preservation of normal lung regions in the adult respiratory syndrome, analysis by computed tomography. JAMA1986;255:2463–2465.
37.
WebbHH, TierneyDF. Experimental pulmonary edema due to intermittent positive pressure ventilation with high inflation pressures: protection by positive end-expiratory pressure. Am Rev Respir Dis1974;110:556–565.
38.
DreyfussD, SolerP, BassetG, SaumonG.High inflation pressure pulmonary edema: respective effects of high airway pressure, high tidal volume, and positive end-expiratory pressure. Am Rev Respir Dis1988;137:1159–1164.
39.
ParkerJC, HernandezLA, LongeneckerGL, PeevyK, JohnsonW.Lung edema caused by high peak inspiratory pressures in dogs: role of increased microvascular filtration pressure and permeability. Am Rev Respir Dis1990;142:321–328.
40.
KolobowT, MorettiMP, FumagalliR, MascheroniD, PratoP, ChenV, . Severe impairment in lung function induced by a high peak airway pressure during mechanical ventilation: an experimental study. Am Rev Respir Dis1987;135:312–315.
41.
CorbridgeTC, WoodLDH, CrawfordGP, ChudobaMJ, YanosJ, SznajderJI. Adverse effects of large tidal volume and low PEEP in canine acid aspiration. Am Rev Respir Dis1990;142(2):311–315.
42.
MuscedereJG, MullenJBM, GanK, BryanAC, SlutskyAS. Tidal ventilation at low airway pressures can cause pulmonary barotrauma (abstract). Am Rev Respir Dis1992;145(4, Part 2):A454.
43.
MariniJJ, RavenscraftSA. Mean airway pressure: physiological determinants and clinical importance. Part 1: physiological determinants and measurements. Crit Care Med1992;20(10):1461–1472.
44.
MariniJJ, RavenscraftSA. Mean airway pressure: physiological determinants and clinical importance. Part 2: clinical implications. Crit Care Med1992;20(11):1604–1616.
45.
AbrahamE, YoshiharaG.Cardiorespiratory effects of pressure controlled ventilation in severe respiratory failure. Chest1990;98:1445–1449.
46.
MarcyTW, MariniJJ. Inverse ratio ventilation in ARDS: rationale and implementation. Chest1991;100 (2):494–504.
47.
StockMC, DownsJB, FrolicherDA. Airway pressure release ventilation. Crit Care Med1987;15:462–466.
48.
RoubyJ-J. Pressure release ventilation. In: VincentJL, ed. Update in intensive care and emergency medicine. Berlin: Springer-Verlag, 1990:185–195.
49.
MariniJJ, CrookePS3rd. A general mathematical model for respiratory dynamics relevant to the clinical setting. Am Rev Respir Dis1993;147(1):14–24.
50.
NahumA, RavenscraftSA, BurkeWC, AdamsAB, MarcyTW, MariniJJ. Tracheal gas insufflation during pressure-control ventilation: effect of catheter position, diameter, and flow rate. Am Rev Respir Dis1992;146:1411–1418.
51.
HicklingKG. Low volume ventilation with permissive hypercapnia in the adult resiratory distress syndrome. Clin Intens Care1992;3:67–68.
52.
DarioliR, PerretC.Mechanical controlled hypoventilation in status asthmaticus. Am Rev Respir Dis1984;129:385–387.
53.
HicklingKG, HendersonSJ, JacksonR.Low mortality associated with low volume pressure limited ventilation with permissive hypercapnia in severe adult respiratory distress syndrome. Intensive Care Med1990;16:372–377.
RavenscraftSA, BurkeWC, MariniJJ. Volume-cycled decelerating flow: an alternative form of mechanical ventilation. Chest1992;101(5):1342–1351.
61.
GattinoniL, PesentiA, MascheroniD, MarcolinR, FumagalliR, RossiF, . Low-frequency positive-pressure ventilation with extracorporeal CO2 removal in severe acute respiratory failure. JAMA1986;256 (7):881–886.
62.
MortensenJD, BerryG.Conceptual and design features of a practical, clinically effective intravenous mechanical blood oxygen/carbon dioxide exchange device (IVOX). Int J Artif Organs1989;12(6):384–389.
63.
RavenscraftSA, BurkeWC, NahumA, AdamsAB, NakosG, MarcyTW, MariniJJ. Tracheal gas insufflation augments CO2 clearance during mechanical ventilation. Am Rev Respir Dis1993 (in press).
64.
GilbertJ, LarssonA, SmithRB, BuneginL.Intermittent-flow expiratory ventilation (IFEV): delivery technique and principles of action-a preliminary communication. Biomed Instrum Technol1991;25:451–456.
65.
BurkeWC, CrookePS, MarcyTW, AdamsAB, MariniJJ. Comparison of mathematical and mechanical models of pressure controlled ventilation. J Appl Physiol1993;74(2):922–933.
66.
LongSE, MenonAS, KatoH, GoldsteinRS, SlutskyAS. Constant oxygen insufflation (COI) in a ventilatory failure model. Am Rev Respir Dis1988;138:630–635.
67.
SlutskyAS, MenonAS. Catheter position and blood gases during constant-flow ventilation. J Appl Physiol1987;62(2):513–519.
68.
KolobowT, MullerE, MandavaS, JonesM, VitaleG, ApriglianoM, . Intratracheal pulmonary ventilation (ITPV): a new technique (abstract). Am Rev Respir Dis1991;143(4, Part 2):A602.
69.
HurewitzAN, BergofskyEH, VomeroE.Airway insufflation: increasing flow rates progressively reduce dead space in respiratory failure. Am Rev Respir Dis1991;144:1229–1233.
70.
BergofskyEH, HurewitzAN. Airway insufflation: physiologic effects on acute and chronic gas exchange in humans. Am Rev Respir Dis1989;140:885–890.
71.
SznajderJI, NahumA, CrawfordG, PollakER, SchumacherPT, WoodLDH. Alveolar pressure inhomogeneity and gas exchange during constant-flow ventilation in dogs. J Appl Physiol1989;67(4):1489–1494.
72.
StresemannE.Washout of anatomical dead space: design of a method and experimental study using an external dead space. Respiration1968;25:281–291.
73.
StresemannE, VotteriB, SattlerFP. Washout of anatomical dead space for alveolar hypoventilation: a preliminary case report. Respiration1969;26:424–434.
74.
NahumA, RavenscraftSA, AdamsAB, BurkeWC, MariniJJ. Efffect of catheter shape on CO2 removal during tracheal gas insufflation in dogs. J Appl Physiol (1993, in press).
75.
BurkeWC, NahumA, RavenscraftSA, NakosG, AdamsAB, MarcyTW, MariniJJ. Modes of tracheal gas insufflation: comparison of continuous phase specific gas injection in normal dogs. Am Rev Respir Dis1993 (in press).
76.
SlutskyAS. Nonconventional methods of ventilation. Am Rev Respir Dis1988;138:175–183.