ChatburnRL, PrimianoFPJr. A rational basis for humidity therapy (editorial). Respir Care1987;32:249–254.
2.
BransonRD. Humidification of inspired gases during mechanical ventilation. RT1991;3:55–66.
3.
American Association for Respiratory Care. Consensus statement on the essentials of mechanical ventilators-1992. Respir Care1992;37:1000–1008.
4.
BransonRD, CampbellRS, ChatburnRL, CovingtonJL. AARC Clinical Practice Guideline: humidification during mechanical ventilation. Respir Care1992;37:887–890.
5.
SimmonsBP, WongES. Guidelines for prevention of nosocomial pneumonia. Am J Infect Control1983;11:230–244.
6.
CravenDE, ConnollyMGJr, LichtenbergDA, PrimeauPJ, McCabeWR. Contamination of mechanical ventilators with tubing changes every 24 or 48 hours. N Engl J Med1982;306:1505–1509.
7.
GrenonJ, ArmstrongL.Five-day changes for heated wire circuits (abstract). Respir Care1991;36:1287.
8.
GallagherJ, StrangewaysJE, Allt-GrahamJ.Contamination control in long-term ventilation: a clinical study using a heat-and-moisture-exchanging filter. Anaesthesia1987;42:476–481.
9.
DreyfussD, DjedainiK, WeberP, BrunP, LanoreJJ, RahmaniJ, . Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change. Am Rev Respir Dis1991;143:738–743.
10.
CravenDE, StegerKA, BaratLM, DuncanRA. Nosocomial pneumonia: epidemiology and infection control. Intensive Care Med1992;18(Suppl 1):S3–S9.
11.
BransonRD, CampbellRS, DavisKJr, JohnsonDJ, PorembkaD.Humidification in the intensive care unit. Chest (in press).
GrenonJ, ArmstrongL.Five-day changes for heated-wire circuits (abstract). Respir Care1991;36:1287.
14.
KacmarekRM, EnglishP, VallendeN, HopkinsCC. Extended use of heated neonatal/pediatric ventilator circuits (HNVC) (abstract). Respir Care1991;36:1287.
15.
ReinarzJA, PierceAK, MaysDB, SanfordJP. The potential role of inhalation-therapy equipment in nosocomial pulmonary infection. J Clin Invest1965;44:831–839.
16.
CabreraHA. An outbreak of Serratia marcescens, and its control. Arch Intern Med1969;123:650–655.
17.
MertzJJ, ScharerL, McClementJH. A hospital outbreak of klebsiella pneumonia from inhalation therapy with contaminated aerosol solutions. Am Rev Respir Dis1967;95:454–460.
18.
CravenDE, GoularteTA, MakeBJ. Contaminated condensate in mechanical ventilator circuits: a risk factor for nosocomial pneumonia?Am Rev Respir Dis1984;129:625–628.
19.
ChristopherKL, SaravolatzLD, BushTL, ConwayWA. The potential role of respiratory therapy equipment in cross infection: a study using a canine model for pneumonia. Am Rev Respir Dis1983;128:271–275.
20.
CravenDE, LichtenbergDA, GoularteTA, MakeBJ, McCabeWR. Contaminated medication nebulizers in mechanical ventilator circuits: source of bacterial aerosols. Am J Med1984;77:834–838.
21.
RoustanJP, KienlenJ, AubasP, AubasS, du CailarJ.Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation. Intensive Care Med1992;18:97–100.
22.
MartinC, PerrinG, GevaudanMJ, SauxP, GouinF.Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest1990;97:144–149.
23.
MissetB, EscudierB, RivaraD, LeclercqB, NitenbergG.Heat and moisture exchanger vs heated humidifier during long-term mechanical ventilation: a prospective randomized study. Chest1991;100:160–163.
24.
CrossAS, RoupB.Role of respiratory assistance devices in endemic nosocomial pneumonia. Am J Med1981;70:681–685.
25.
EckerbomB, LindholmCE. Performance evaluation of six heat and moisture exchangers according to the Draft International Standard (ISO/DIS 9360). Acta Anaesthesiol Scand1990;34:404–409.
26.
EckerbomB, LindholmCE. Laboratory evaluation of heat and moisture exchangers. assessment of the Draft International Standard (ISO/DIS 9360) in practice. Acta Anaesthesiol Scand1990;34:291–295.
27.
BransonRD, HurstJM. Laboratory evaluation of moisture output of seven airway heat and moisture exchangers. Respir Care1987;32:741–747.
28.
ShellyMP, BethuneDW, LatimerRD. A comparison of five heat and moisture exchangers. Anaesthesia1986;41:527–532.
29.
WeeksDB, RamseyFM. Laboratory investigation of six artificial noses for use during endotracheal anesthesia. Anesth Analg1983;62:758–763.
30.
BicklerPE, SesslerDI. Efficiency of airway heat and moisture exchangers in anesthetized humans. Anesth Analg1990;71:415–418.
31.
CohenIL, WeinbergPF, FeinIA, RowiniskiGS. Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit. Crit Care Med1988;16:277–279.
32.
SuzukawaM, UsudaY, NumataK.The effects on sputum characteristics of combining an unheated humidifier with a heat-moisture exchanging filter. Respir Care1989;34:976–984.
33.
AllenE.Abnormalities in temperature regulation. In: BlumerJL, editor. A practical guide to pediatric intensive care, 3rd ed. Chicago: Mosby-Year book; 1990:126–135.
34.
HorvathAL. Conversion tables of units for science and engineering. New York: Elsevier; 1986.
35.
WalkerJEC, WellsREJr, MerrillEW. Heat and water exchange in the respiratory tract. Am J Med1961;30:259–267.
36.
VareneP.Computation of respiratory heat exchanges. J Appl Physiol1986;61:1586–1589.
37.
LloydEL, ConliffeNA, OrgelH, WalkerPN. Accidental hypothermia: an apparatus for central rewarming as a first aid measure. Scott Med J1972;17:83–91.
38.
CollinsML, SteinmanAM, ChaneyRD. Accidental hypothermia: an experimental study of practical rewarming methods. Aviat Space Environ Med1977;48:625–632.
39.
HaywardJS, SteinmanAM. Accidental hypothermia: an experimental study of inhalation rewarming. Aviat Space Environ Med1975;46:1236–1240.
40.
HaywardJS, EckersonJD, KemnaD.Thermal and cardiovascular changes during three methods of resuscitation from mild hypothermia. Resuscitation1984;11:21–33.
41.
MorrisonJB, ConnML, HayesPA. Influence of respiratory heat transfer on thermogenesis and heat storage after cold immersion. Clin Sci1982;63:127–135.
42.
GuildWJ. Rewarming via the airway (CBRW) for hypothermia in the field?JR Nav Med Serv1978;64:186–193.
43.
MarcusP.Laboratory comparison of technique for rewarming hypothermic casualties. Aviat Space Environ Med1978;49:692–697.
44.
RometTT, HoskinRW. Temperature and metabolic responses to inhalation and bath rewarming protocols. Aviat Space Environ Med1988;59:630–634.
IngelstedtS.Studies on conditioning of air in the respiratory tract. Acta Otolaryngol1956;131(Suppl):1–71.
47.
DeryR, PelletierJ, JaquesA, ClavetM, HouseJJ. Humidity in anesthesiology: heat and moisture patterns in the respiratory tract during anesthesia with the semi-closed system. Can Anaesth Soc J1967;14:287–298.