HarrisTR. Physiological principles. In: GoldsmithJP, KarotkinEH, eds. Assisted ventilation of the neonate. 2nd ed. Philadelphia: WB Saunders Co, 1988:22–69.
2.
SpearmanCB, SheldonRL. Egan's fundamentals of respiratory therapy. 4th ed. St Louis: CV Mosby Co, 1982:564.
3.
ShusterDP. A physiologic approach to initiating, maintaining, and withdrawing mechanical ventilatory support during acute respiratory failure. Am J Med1990;88:268–278.
4.
SeleckyPA, WassermanK, KleinM, ZimentI.A graphic approach to assessing the interrelationships among minute ventilation, arterial carbon dioxide tension, and ratio of physiologic dead space to tidal volume in patients on respirators. Am Rev Respir Dis1978;117:181–184.
5.
WestJB. Respiratory physiology: The essentials. Baltimore: Williams & Wilkins, 1974:65.
6.
GrossR, IsraelRH. A graphic approach for prediction of arterial oxygen tension at different concentrations of inspired oxygen. Chest1981;79:311–315.
7.
BenatarSR, HewlettAM, NunnJF. The use of iso-shunt lines for control of oxygen therapy. Br J Anaesth1973;45:711–725.
HicklingKG. Ventilatory management of ARDS: Can it affect the outcome?Intensive Care Med1990;16:219–226.
10.
ThibeaultDW, LangMJ. Mechanisms and pathobiologic effects of barotrauma. In: MerrittTA, NorthwayWHJr, BoyntonBR, eds. Bronchopulmonary dysplasia. Boston: Blackwell Scientific Publications, 1988:79–101.
11.
CaldwellEJ, PowellRD, MulloolyJP. Interstitial emphysema: A study of physiologic factors involved in experimental induction of the lesion. Am Rev Respir Dis1970;102:516–525.
12.
HernandezLA, PeevyKJ, MoiseAA, ParkerJC. Chest wall restriction limits high airway pressure-induced lung injury in young rabbits. J Appl Physiol1989;66:2364–2368.
13.
DreyfussD, SolerP, BassetG, SaumonG.High inflation pressure pulmonary edema. Respective effects of high airway pressure, high tidal volume, and positive end-expiratory pressure. Am Rev Respir Dis1988;137:1159–1164.
14.
DreyfussD, SolerP, SaumonG.Overinflation pulmonary edema is not related to large volume swings but to the level of lung distension (abstract). Am Rev Respir Dis1989;139(4, Part 2):A417.
15.
ThibeaultDW, LachmanRS, LaulVR, KwongMS. Pulmonary interstitial emphysema, pneumomediastinum, and pneumothorax. Occurrence in the newborn infant. AJDC1973;126:611–614.
NilssonR, GrossmanG, RobertsonB.Pathogenesis of neonatal lung lesions induced by artificial ventilation: Evidence against the role of barotrauma. Respiration1980;4:218–225.
NilssonR, BerggrenP, CurstedtT, GrossmanG, RenheimG, RobertsonB.Surfactant treatment and ventilation by high frequency oscillation in preterm newborn rabbits: Effect on survival, lung aeration, and bronchiolar epithelial lesions. Pediatr Res1985;19:143–147.
20.
AckermanNBJr, CoalsonJJ, KuehlTJ, . Pulmonary interstitial emphysema in the premature baboon with hyaline membrane disease. Crit Care Med1984;12:512–516.
21.
MenkesH, GardinerA, GamsuG, LempertJ, MacklemPT. Influence of surface forces on collateral ventilation. J Appl Physiol1971;31:544–549.
22.
MenkesHA, MacklemPT. Collateral flow. In: FishmanAP, ed. Handbook of physiology. Section 3. The respiratory system, Vol 3. Mechanics of breathing, Part 1. Baltimore: Williams & Wilkins, 1986:337–353.
23.
GreavesIA, HildebrandTJ, HoppinFG. Micromechanics of the lung. In: FishmanAP, ed. Handbook of physiology. Section 3. The respiratory system, Vol 3. Mechanics of breathing, Part 1. Baltimore: Williams & Wilkins, 1986:217–231.
24.
MacklinMT, MacklinCC. Malignant interstitial emphysema of the lungs and mediastinum as an important occult complication in many respiratory diseases and other conditions: An interpretation of the clinical literature in the light of laboratory experiment. Medicine1944;23:281–352.
25.
KumarA, ClutarioBC, DoyleC, ScarpelliEM. Time-dependency and static mechanics of immature airways and saccules. Respir Physiol1983;51:195–207.
26.
MeadJ, TakishimaT, LeithD.Stress distribution in lungs: A model of pulmonary elasticity. J Appl Physiol1970;28:596–608.
27.
TaghizadehA, ReynoldsEOR. Pathogenesis of bronchopulmonary dysplasia following hyaline membrane disease. Am J Pathol1976;82:241–246.
28.
ChatburnRL, PrimianoFPJr. Mathematical models of respiratory mechanics. In: ChatburnRL, CraigKC, eds, Fundamentals of respiratory care research. Norwalk: Appleton & Lange, 1988:59–100.
29.
FuhrmanBP, Smith-WrightDL, VenkataramanS, OrrRA, HowlandDF. Proximal mean airway pressure: A good estimator of mean alveolar pressure during continuous positive pressure breathing. Crit Care Med1989;17:666–670.
30.
Perez-FontanJJ, HeldtGP, GregoryGG. The effect of a gas leak around the endotracheal tube on the mean tracheal pressure during mechanical ventilation. Am Rev Respir Dis1985;132:339–342.
31.
HermanS, ReynoldsEOR. Methods for improving oxygenation in infants mechanically ventilated for severe hyaline membrane disease. Arch Dis Child1973;48:612–617.
32.
BorosSJ, MatalonSV, EwaldR, LeonardAS, HungCE. The effect of independent variations in inspiratory-expiratory ratio and end expiratory pressure during mechanical ventilation in hyaline membrane disease: The significance of mean airway pressure. J Pediatr1977;91:794–798.
33.
BorosSJ. Variations in inspiratory-expiratory ratio and airway pressure waveform during mechanical ventilation: The significance of mean airway pressure. J Pediatr1979;94:114–117.
34.
BorosSJ, CampbellK.A comparison of the effects of high frequency-low tidal volume and low frequency-high tidal volume mechanical ventilation. J Pediatr1980;97:108–112.
35.
CiszekTA, ModanlouHD, OwingsD, NelsonP.Mean airway pressure-Significance during mechanical ventilation in neonates. J Pediatr1981;99:121–126.
36.
GallagherTJ, BannerMJ. Mean airway pressure as a determinant of oxygenation (abstract). Crit Care Med1980;8:244.
37.
StewartA, FinerN, PetersK.Effects of alterations of inspiratory and expiratory pressures and inspiratory/expiratory ratios on mean airway pressure, blood gases, and intracranial pressure. Pediatrics1981;67:474–481.
38.
RamsdenCA, ReynoldsEOR. Ventilator settings for newborn infants. Arch Dis Child1987;62:529–538.
39.
BhutaniVK, SivieriEM, AbbasiS, ShafferTH. Evaluation of neonatal pulmonary mechanics and energetics: A two factor least mean square analysis. Pediatr Pulmonol1988;4:150–158.
40.
Perez-FontanJJ, HeldtGP, TargettRC, WillisMM, GregoryGA. Dynamics of expiration and gas trapping in rabbits during mechanical ventilation at rapid rates. Crit Care Med1986;14:39–47.
41.
MariniJJ, CrookePSIII, TruwitJD. Determinants and limits of pressure-preset ventilation: A mathematical model of pressure control. J Appl Physiol1989;67:1081–1092.
42.
KacmarekRM, HessD.Pressure-controlled inverse ratio ventilation: Panacea or auto-PEEP? (editorial). Respir Care1990;35:945–948.
43.
ManginelloFP, GrassiAE, SchechnerS, KraussAN, AuldPAM. Evaluation of methods of assisted ventilation in hyaline membrane disease. Arch Dis Child1978;53:878–881.
44.
LachmannB.How to set the ventilator in acute respiratory failure. Middle East J Anesthesiol1990;10:367–375.
45.
LachmannB, JonsonB, LindrothM, RobertsonB.Modes of artificial ventilation in severe respiratory distress syndrome. Lung function and morphology in rabbits after wash-out of alveolar surfactant. Crit Care Med1982;10:724–732.
46.
MultzAS, AldrichTK, PrezantDJ, KarpelJP, HendlerJM. Maximal inspiratory pressure is not a reliable test of inspiratory muscle strength in mechanically ventilated patients. Am Rev Respir Dis1990;142:529–532.
47.
ChatburnRL, LoughMD, PrimianoFPJr. Mechanical ventilation. In: ChatburnRL, LoughMD, eds. Handbook of respiratory care. 2nd ed. Chicago: Mosby-Year Book Medical Publishers, 1990:159–223.
48.
MushinWW, Rendell-BakerL, ThompsonPW, MaplesonWW. Automatic ventilation of the lungs. 3rd ed. Oxford: Blackwell Scientific Publications, 1980:62–131.
49.
ChatburnRL, PrimianoFPJr. A rational basis for humidity therapy. Respir Care1987;32:249–253.
50.
ChatburnRL. Physiological and methodologic issues regarding humidity therapy. J Pediatr1989;114:416–420.
51.
Tarno-MordiWO, ReidE, GriffithsP, WilkinsonAR. Low inspired gas temperature and respiratory complications in very low birth weight infants. J Pediatr1989;114:438–442.
52.
NullD, BermanLS, ClarkR.Neonatal and pediatric ventilatory support. In: KirbyRR, BannerMJ, DownsJB, eds. Clinical applications of ventilatory support. New York: Churchill Livingstone, 1990:199–238.
53.
GoldsmithJP, KarotkinEH. Assisted ventilation of the neonate. 2nd ed. Philadelphia: WB Saunders Co, 1988:146–170, 171–189, 409–429.
54.
GioiaFR, StephensonRL, AlterwitzSA. Principles of respiratory support and mechanical ventilation. In: RogersMC, ed. Textbook of pediatric intensive care. Vol 1. Baltimore: Williams & Wilkins, 1987:113–169.
55.
CarloWA, ChatburnRL. Assisted ventilation of the newborn. In: CarloWA, ChatburnRL, eds. Neonatal respiratory care. 2nd ed. Chicago: Mosby-Year Book, 1988:320–346.
KanterRK, BlattSD, ZimmermanJJ. Initial mechanical ventilator settings for pediatric patients: Clinical judgment in selection of tidal volume. Am J Emerg Med1987;5:113–117.
58.
MörchET. History of mechanical ventilation. In: KirbyRR, BannerMJ, DownsJB, eds. Clinical applications of ventilatory support. New York: Churchill Livingstone, 1990:1–61.
59.
AdamsTM, CollinsLM, DehanM, HawkerJM, ReynoldsEOR, StrangLB. Mechanical ventilation in newborn infants with respiratory failure. Lancet1968;2:227–231.
60.
ReynoldsEOR. Indications for mechanical ventilation in infants with hyaline membrane disease. Pediatrics1970;46:193–202.
61.
HermanS, ReynoldsEOR. Methods for improving oxygenation in infants mechanically ventilated for severe hyaline membrane disease. Arch Dis Child1973;48:612–617.
62.
ReynoldsEOR. Effects of alterations in mechanical ventilator settings on pulmonary gas exchange in hyaline membrane disease. Arch Dis Child1971;46:152–159.
63.
ReynoldsEOR. Pressure wave form and ventilator settings for mechanical ventilation in very severe hyaline membrane disease. Int Anesthesiol Clin1973;12:259–280.
64.
ReynoldsEOR. Management of hyaline membrane disease. Br Med Bull1975;31:81–84.
65.
ReynoldsEOR, TaghizadehA.Improved prognosis of infants mechanically ventilated for hyaline membrane disease. Arch Dis Child1974;49:505–515.
66.
KirbyRR, RobinsonEJ, SchultzJ, DeLemosR.A new pediatric volume ventilator. Anesth Analg1971;50:533–537.
67.
PrimahakRA. Factors associated with pulmonary air leak in premature infants receiving mechanical ventilation. J Pediatr1983;102:764–768.
68.
MehtaA, CallanK, WrightBM, StaceyTE. Patient triggered ventilation in the newborn. Lancet1986;2:706–712.
69.
GreenoughA, GreenallF.Patient triggered ventilation in premature neonates. Arch Dis Child1988;63:77–78.
GreenoughA, MorleyC, DavisJ.Interaction of spontaneous respiration with artificial ventilation in preterm babies. J Pediatr1983;103:769–773.
72.
LipscombAP, ThorburnRJ, ReynoldsEOR, . Pneumothorax and cerebral haemorrhage in preterm infants. Lancet1981;1:414–416.
73.
MitchellA, GreenoughA, HirdM.Limitations of patient triggered ventilation in neonates. Arch Dis Child1989;64:924–929.
74.
AndersenJB. Inverse I:E ratio ventilation with pressure control in catastrophic lung disease in adults: Another lesson to be learned from neonatal intensive care?Intensive Care World1987;4:21–23.
75.
Tarnow-MordiWO, NarangA, WilkinsonAR. Lack of association between barotrauma and air leak in hyaline membrane disease. Arch Dis Child1985;60:555–559.
76.
BlandRD, KimMH, LightMJ, WoodsonJL. High frequency mechanical ventilation in severe hyaline membrane disease. Crit Care Med1980;8:275–280.
77.
SpahrRC, KleinAM, BrownDR, MacDonaldHM, HolzmanIR. Hyaline membrane disease: A controlled study of inspiratory to expiratory ratio in its management by ventilator. AJDC1980;134:373–376.
78.
HeicherDA, KastingDS, HarrodJR. Prospective clinical comparison of two methods for mechanical ventilation of neonates: Rapid rate and short inspiratory time versus slow rate and long inspiratory time. J Pediatr1981;98:957–961.
79.
RamsdenCA, ReynoldsEOR. Commentary (letter to the editor). Arch Dis Child1987;62:537–538.
80.
MortolaJP, FisherJT, SmithB, FoxG, WeeksS.Dynamics of breathing in infants. J Appl Physiol1982;52:1209–1215.
81.
ThomsonA, SilvermanM.Single-breath measurement of lung mechanics in very low birthweight infants. Crit Care Med1985;13:4–8.
82.
Le SouefPN, EnglandSJ, BryanAC. Passive respiratory mechanics in newborns and children. Am Rev Respir Dis1984;128:552–556.
83.
GrunsteinMM, InscoreSC. A new method to assess respiratory mechanics in infants with pulmonary disease (abstract). Pediatr Res1986;20:472A.
84.
PrendivilleA, ThomasA, SilvermanM.Effect of tracheobronchial suction on respiratory resistance in intubated preterm babies. Arch Dis Child1986;61:1178–1183.
85.
KoschPC, StarkAR. Dynamic maintenance of end expiratory lung volume in full term infants. J Appl Physiol1984;57:1126–1133.
86.
MorleyC, SouthM.Commentary (letter to the editor). Arch Dis Child1987;62:535.
87.
MilnerAD. Commentary (letter to the editor). Arch Dis Child1987;62:540–541.
88.
GreenoughA, PoolJ, GreenallF, MorleyCJ, GarnsuH.Comparison of different rates of artificial ventilation in preterm neonates with respiratory distress syndrome. Acta Paediatr Scand1987;76:706–712.
89.
HallJB, WoodLOH. Liberation of the patient from mechanical ventilation. JAMA1987;257:1621–1628.
90.
BoyarskyA, SenezJ.Optimal pressure waveforms for pressure-limited ventilation. IMA Journal of Mathematics Applied in Medicine & Biology1987;4:201–205.
91.
Ben-HaimSA, DennarU, SaideGM. Optimal design of mechanical ventilator waveform, using a mathematical model of the ventilatory system. Med Biol Eng Comput1988;26:419–424.
92.
BergmanNA. Effect of varying respiratory waveforms on distribution of inspired gas during artificial ventilation. Am Rev Respir Dis1969;100:518–525.
93.
CorbridgeTC, WoodLDI, CrawfordGP, ChudobaMJ, YanosJ, SznajderJI. Adverse effects of large tidal volume and low PEEP in canine acid aspiration. Am Rev Respir Dis1990;142:311–315.
94.
BorosSJ, BingDR, MammelMC, HagenE, GordonMJ. Using conventional ventilators at unconventional rates. Pediatrics1984;74:487–492.
95.
CarloWA, ChatburnRL, MartinRJ, . Decrease in airway pressure during high-frequency jet ventilation in infants with respiratory distress syndrome. J Pediatr1984;104:101–107.
96.
CarloWA, ChatburnRL, MartinRJ. Randomized trial of high-frequency jet ventilation versus conventional ventilation in respiratory distress syndrome. J Pediatr1987;110:275–282.
97.
CarloWA, SinerB, ChatburnRL, RobertsonS, MartinRJ. Early randomized intervention with high-frequency jet ventilation in respiratory distress syndrome. J Pediatr (in press).
98.
ChatburnRL, CarloWA. Assessment of neonatal gas exchange. In: CarloWA, ChatburnRL. Neonatal respiratory care. 2nd ed. Chicago: Mosby-Year Book, 1988:40–60.
99.
LeePC, HelsmoortelCM, CohnSM, FinkMP. Are low tidal volumes safe?Chest1990;97:425–429.
100.
BendixenHH, Hedley-WhiteJ, LaverMB. Impaired oxygenation in surgical patients during general anesthesia with controlled ventilation. N Engl J Med1963;269:991–996.
101.
CarloWA, PacificoL, ChatburnRL. Efficacy of computer-assisted management of respiratory failure in neonates. Pediatrics1986;78:139–143.
102.
MillerPL. Goal-directed critiquing by computer: Ventilator management. Comput Biomed Res1985;18:422–438.