SacknerMA, KriegerBP. Non-invasive respiratory monitoring. In: ScharfSM, CassidyS, eds. Heart-lung interactions in health and disease. New York: Marcel Dekker Inc, 1989:663–805.
3.
MacIntyreN.Respiratory monitoring without machinery. Respir Care1990;35:546–556.
4.
KonnoK, MeadJ.Measurement of the separate volume changes of rib cage and abdomen during breathing. J Appl Physiol1967;22:407–422.
5.
SharpJT, GoldbergNB, DruzWS, DanonJ.Relative contributions of rib cage and abdomen to breathing in normal subjects. J Appl Physiol1975;39:608–618.
6.
ChadhaTS, WatsonH, BirchS, . Validation of respiratory inductive plethysmography using different calibration procedures. Am Rev Respir Dis1982;125:644–649.
7.
MorelDR, ForsterA, SuterPM. Non-invasive ventilatory monitoring with bellows pneumograph in supine subjects. J Appl Physiol1983;55:598–605.
8.
TobinMJ, JenouriG, BirchS, . Effect of positive end-expiratory pressure on breathing patterns of normal subjects and intubated patients with respiratory failure. Crit Care Med1983;11:859–867.
9.
SacknerMA, WatsonH, BelsitoAS, . Calibration of respiratory inductive plethysmography during natural breathing. J Appl Physiol1989;66:410–420.
10.
National Institutes of Health Consensus Development Conference Statement. Infantile apnea and home monitoring. U.S. Department of Health and Human Services, National Institute of Health Publication No. 87-2905, 1987.
11.
SacknerM, BizouskyF, GazerogluH, KriegerB.Performance of impedance pneumograph (IP) and respiratory inductive plethysmograph (RIP) related to spirometer (SP) (abstract). Fed Proc1987;46:1426.
12.
WatsonH.Technology of respiratory inductive plethysmography. In: StottFD, RafteryEB, GouldingL, eds. ISAM Proceedings of the Third International Symposium on Ambulatory Monitoring. London: Academic Press, 1980:537–558.
13.
WatsonHL, PooleDA, SacknerMA. Accuracy of respiratory inductive plethysmographic measurement of cross-sectional area of models. J Appl Physiol1988;65:306–308.
14.
KriegerBP, ChediakA, GazerogluHB, BizouskyFP. Variability of the breathing pattern before and after extubation. Chest1988;93:767–771.
15.
KriegerBP, ErshowskyP.Noninvasive detection of respiratory failure in the intensive care unit. Chest1988;94:254–261.
16.
KriegerB, FeinermanD, ZaronA, BizouskyF.Continuous noninvasive monitoring of respiratory rate in critically ill patients. Chest1986;90:632–634.
17.
TobinMJ, PerezW, GuentherSM, . The pattern of breathing during successful and unsuccessful trials of weaning from mechanical ventilation. Am Rev Respir Dis1986;134:1111–1118.
18.
CohenCA, ZagelbaumG, GrossD, RoussosC, MacklemPT. Clinical manifestations of inspiratory muscle fatigue. Am J Med1982;73:308–316.
TobinMJ, GuentherSM, PerezW, . Konno-Mead analysis of rib cage-abdominal motion during successful and unsuccessful trials of weaning from mechanical ventilation. Am Rev Respir Dis1987;135:1320–1328.
24.
BurnsDM. Mechanical ventilation: Weaning and complications. In: BordowRA, MoserKM, eds. Manual of clinical problems in pulmonary medicine. Boston: Little, Brown & Co, 1985:241–244.
25.
KriegerB, ShaneD, GazerogluHB, SacknerMA. Timing of extubation—Medical and economic implications (abstract). Am Rev Respir Dis1986;133:A354.
26.
KriegerB, ErshowskyP, WiencekB, GazerogluH.Use of respiratory monitors in expediting extubations in the intensive care unit (abstract). Chest1987;92(Suppl):100S.
27.
HoffmanR, YahrW, KriegerB.Diaphragmatic flutter resulting in failure to wean from mechanical ventilator support following coronary artery bypass surgery. Crit Care Med1990;18:499–501.
28.
HoffmanRA, ErshowskyP, KriegerBP. Determination of auto-PEEP during spontaneous and controlled ventilation by monitoring changes in end-expiratory thoracic gas volume. Chest1989;96:613–616.
29.
BrandoleseR, BernascniM, PoggiR, . Effects of PEEP on respiratory mechanics and gas exchange in mechanically ventilated patients with ARDS and acute exacerbations of COPD (abstract). Am Rev Respir Dis1988;137(4, Part 2):470.
30.
BensonMS, PiersonDJ. Auto-PEEP during mechanical ventilation of adults. Respir Care1988;33:557–568.
31.
MariniJJ, PepePE. Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction: The auto-PEEP effect. Am Rev Respir Dis1982;126:166–170.
32.
KriegerBP, ErshowskyP, SpivackD, ThorstensonJ, SacknerMA. Initial experience with a central respiratory monitoring unit as a cost saving alternative to the intensive care unit for Medicare patients who require long-term ventilator support. Chest1988;93:395–397.
33.
KriegerB, ErshowskyP.Non-invasively monitored intermediate care unit (NIMU) for patients requiring prolonged mechanical ventilator support (MVS)—One year's experience (abstract). Chest1989;96(Suppl):300S.
34.
SpivackD.The high cost of acute health care: A review of escalating costs and limitations of such exposure in intensive care units. Am Rev Respir Dis1987;136:1007–1011.
35.
RubinsHB, MoskowitzMA. Discharge decision making in a medical intensive care unit. Identifying patients at high risk of unexpected death or unit readmission. Am J Med1988;84:863–869.
36.
American Thoracic Society. Indications and standards for cardiopulmonary sleep studies. Am Rev Respir Dis1989;139:559–568.
37.
StaatsBA, BonekatHW, HarrisCD, OffordKP. Chest wall motion in sleep apnea. Am Rev Respir Dis1984;130:59–63.
38.
TobinMJ, JenouriGA, WatsonH, SacknerMA. Noninvasive measurement of pleural pressure by surface inductive plethysmography. J Appl Physiol1983;55:267–275.
39.
KacmarekRM. Noninvasive monitoring of respiratory function outside of the hospital. Respir Care1990;35:719–727.
SacknerMA. Effects of hydrocodone bitartrate on breathing pattern of patients with chronic obstructive pulmonary disease and restrictive lung disease. Mt Sinai J Med (NY)1984;51:222–226.
42.
BarkinJS, KriegerB, BlinderM, Bosch-BlinderL, GoldbergRI, PhillipsRS. Oxygen desaturation and changes in breathing pattern in patients undergoing colonoscopy and gastroscopy. Gastro Endo1989;35:526–530.