HessD.An overview of noninvasive monitoring in respiratory care: Present, past, and future. Respir Care1990;35:482–499.
2.
EichornJH, CooperJB, CullenDJ, MaierWR, PhilipJH, SeemanRG. Standards for patient monitoring during anesthesia at Harvard Medical School. JAMA1986;266:1017–1020.
3.
ChoiHJ. End-tidal PCO₂: Should it be a standard of care in obstetric anesthesia (letter)?Anesthesiology1986;64:829–830.
4.
SwedlowDB. Capnometry and capnography: The anesthesia disaster early warning system. Seminars in Anesthesia1986;5:194–205.
5.
GravensteinJS, PaulusDA, HayesTJ. Capnography in clinical practice. Boston: Butterworths, 1989.
PaloheimoMPJ. A carbon dioxide monitor that does not show the waveform has value. J Clin Monit1988;4:210–212.
8.
BlockFE. A carbon dioxide monitor that does not show the waveform is worthless. J Clin Monit1988;4:213–214.
9.
SchenaJ, ThompsonJ, CroneRK. Mechanical influences on the capnogram. Crit Care Med1984;12:672–674.
10.
GravensteinN, LampotangS, BenekenJEW. Factors infuencing capnography in the Bain circuit. J Clin Monit1985;1:6–10.
11.
EpsteinRA, ReznikAM, EpsteinMAF. Determinants of distortions in CO2 catheter sampling systems: A mathe-matical model. Respir Physiol1980;41:127–136.
12.
FromRP, ScammanFL. Ventilatory frequency influences accuracy of end-tidal CO2 measurements. Analysis of seven capnometers. Anesth Analg1988;67:884–886.
13.
van GenderingenHR, GravensteinN.Capnogram artifact during high airway pressures caused by a water trap. Anesth Analg1987;66:185–187.
14.
LerouJGC, van EgmondJ, KolmerHHB. The influence of tube geometry on the performance of long sampling tubes in respiratory mass spectrometry. Clin Phys Physiol Meas1986;7:125–137.
15.
LawsonD, JelenichS.Capnographs: A new operating room pollution hazard (letter)?Anesth Analg1985;64:377–382.
16.
CozanitisDA, PaloheimoMPJ. Operating room pollu-tion from "capnographs" (letter). Anesth Analg1986;65:990–991.
17.
ZupanJ, MartinM, BenumofJL. End-tidal CO2 excretion waveform and error with gas sampling line leak. Anesth Analg1988;67:579–581.
SeveringhausJW, LarsonCP, EgerEI. Correction factors for infrared carbon dioxide pressure broadening by nitrogen, nitrous oxide and cyclopropane. Anesthesiology1961;22:429–432.
20.
AmmannECB, GalvinRD. Problems associated with the determination of carbon dioxide by infrared absorption. J Appl Physiol1968;25:333–335.
21.
CormackRS, PowellJN. Improving the performance of the infra-red carbon dioxide meter. Brit J Anesth1972;44:131–141.
22.
KennellEM, AndrewsRW, WollmanH.Correction factors for nitrous oxide in the infrared analysis of carbon dioxide. Anesthesiology1973;39:441–443.
23.
American Society for Testing & Materials. Capnometers. Standard F-20.03.11 (draft). Philadelphia: Am Soc for Testing & Materials, 1989.
24.
OlssonSG, FletcherR, JonsonB, NordstromL, PrakashO.Clinical studies of gas exchange during ventilatory support a method using the Siemens-Elema CO2 analyzer. Br J Anaesth1980;52:491–499.
25.
FletcherR, WernerO, NordstromL, JonsonB.Sources of error and their correction in the measurement of carbon dioxide elimination using the Siemens-Elema CO2 analyzer. Br J Anaesth1983;55:177–185.
26.
Carbon dioxide monitors. Health Devices1986;15:255–284.
27.
HicksGH, HaynesG, BoydT, GishD.The comparative accuracy of four infrared PetCO₂ analyzers (abstract). Respir Care1988;33:951–952.
28.
SeamanFL, FromRP. High frequency response of six capnometers (abstract). Anesthesiology1989;71:A360.
29.
FowlerKT, Hugh-JonesP.Mass spectrometry applied to clinical practice and research. Br Med J1957;1:1205–1211.
30.
McAslanTC. Automated respiratory gas monitoring of critically injured patients. Crit Care Med1976;4:255–260.
31.
AyresSM. Use of mass spectrometry for evaluation of respiratory function in the critically ill patient. Crit Care Med1976;4:219–222.
32.
RikerJB, HabermanB.Expired gas monitoring by mass spectrometry in a respiratory intensive care unit. Crit Care Med1976;4:223–229.
33.
YakulisR, SnyderJV, PownerD, FuscoD, GrenvikA.Mass spectrometry monitoring of respiratory variables in an intensive care unit. Respir Care1978;23:671–679.
34.
OzanneGM, YoungWG, MazzeiWJ, SeveringhausJW. Multipatient anesthetic mass spectrometry: Rapid analysis of data stored in long catheters. Anesthesiology1981;55:62–70.
35.
GrevisseP, DelcambreY, PicartP, . Turning the mass spectrometer into an easy to handle clinical instrument for routine multipatient surveillance of respiratory and anesthetic gases during anesthesia. Acta Anaesthesiol Belg1987;38:37–44.
36.
BlanksST, KingP, SmithBE. Anesthesia gas monitoring: Central system or stand-alone?Med Instrum1988;22:165–160.
37.
PatelAJ, ChoiC, GiuffridaJG. Changes in end tidal CO2 and arterial blood gas levels after release of tourniquet. South Med J1987;80:214–216.
38.
BaudendistelL, GoudsouzianN, CoteC, StraffordM.End tidal CO2 monitoring: Its use in the diagnosis and management of malignant hyperthermia. Anesthesia1984;39:1000–1003.
39.
TulouPP, WalshPM. Measurement of alveolar carbon dioxide tension at maximal expiration as an estimate of arterial carbon dioxide tension in patients with airway obstruction. Am Rev Respir Dis1970;102:921–926.
40.
MoorthySS, LasassoAM, WilcoxJ.End-tidal Pco2 greater than Paco2. Crit Care Med1984;12:534–535.
41.
ShankarKB, MoseleyH, KumarY.Arterial to end tidal carbon dioxide tension differences during caesarean section anesthesia. Anesthesia1986;41:678–702.
42.
FletcherR, JonsonB.Deadspace and the single breath test for carbon dioxide during anesthesia and artificial ventilation: Effects of tidal volume and frequency of respiration. Br J Anaesth1984;56:109–119.
43.
JonesNL, McHardyJR, NaimarkA, CampbellEJM. Physiological dead space and alveolar-arterial gas pressure differences during exercise. Clin Sci1966;31:19–26.
44.
JonesNL, RobertsonDG, KaneJW. Difference between end-tidal and arterial Pco2 in exercise. J Appl Physiol1979;47:954–960.
45.
DonatiF, MailleJ, BlainR, BoulangerM, SahabP.End tidal carbon dioxide tension and temperature changes after coronary artery bypass surgery. Can Anaesth Soc J1985;32:272–277.
46.
PhanCQ, TremperKK, LeeSE, BarkerSJ. Noninvasive monitoring of carbon dioxide: A comparison of the partial pressure of transcutaneous and end-tidal carbon dioxide with the partial pressure of arterial carbon dioxide. J Clin Monit1987;3:149–154.
47.
WhitesellR, AsiddaoC, GollmanD, JablonskiJ.Relationship between arterial and peak expired carbon dioxide pressure during anesthesia and factors influencing the difference. Anesth Analg1981;60:508–512.
48.
NunnJF, HillDW. Respiratory dead space and arterial to end-tidal CO2 tension difference in anesthetized man. J Appl Physiol1960;15:383–389.
49.
HoffmanRA, KriegerBP, KramerMR, . End-tidal carbon dioxide in critically ill patients during changes in mechanical ventilation. Am Rev Respir Dis1989;140:1265–1268.
50.
DasJB, JoshiID, PhilippartAI. End-tidal CO2 and tissue pH in the monitoring of acid-base changes: A composite technique for continuous, minimally invasive monitoring. J Pediatr Surg1984;19:758–763.
51.
TakkiS, AromaaU, KausteA.The validity and usefulness of the end-tidal Pco2 during anesthesia. Ann Clin Res1972;4:278–284.
52.
PerrinF, PerrotD, HolzapfelL, RobertD.Simultaneous variations of Paco2 and PAco2 in assisted ventilation. Br J Anaesth1983;55:525–530.
53.
RaemerDB, FrancisD, PhilipJH, GabelRA. Variation in Pco2 between arterial blood and peak expired gas during anesthesia. Anesth Analg1983;62:1065–1069.
54.
KalendaZ.Capnography during anesthesia and intensive care. Acta Anaesthesiol Belg1978;29:201–228.
55.
CarlonGC, RayC, MiodownikS, KopecI, GroegerJS. Capnography in mechanically ventilated patients. Crit Care Med1988;16:550–556.
56.
SmalhoutB, KalendaZ.Atlas of capnography. Vol I. The Netherlands: Kerckebosch-Zeist, 1975.
FowlerKT, ReadJ.Cardiac oscillations in expired gas tensions, and regional pulmonary blood flow. J Appl Physiol1961;16:863–868.
59.
BoweEA, BoysenPG, BroomeJA, KleinEF. Accurate determination of end-tidal carbon dioxide during administration of oxygen by nasal cannula. J Clin Monit1989;5:105–110.
60.
IbarraE, LeesDE. Mass spectrometer monitoring of patients with regional anesthesia (letter). Anesthesiology1985;63:572–573.
61.
MachinJR, MacNeilA.Gas sampling from a facemask for capnography. Anesthesia1986;41:971–972.
62.
TurnerKE, SandlerAN, VosuHA, LauL.Noninvasive monitoring of carbon dioxide in non-intubated postoper-ative patients: Comparison of PaCO2 versus etCO2 versus tcPCO₂ (abstract). Anesth Analg1989;68:S295.
63.
NormanEA, ZiegNJ, AhmadI.Better design for mass spectrometer monitoring of the awake patient (letter). Anesthesiology1986;64:664.
64.
HuntingtonCT, KingH.A simpler design for mass spectrometer monitoring of the awake patient (letter). Anesthesiology1986;65:565–566.
65.
GoldmanJM. A simple, easy, and inexpensive method for monitoring PetCO2 through nasal cannulae (letter). Anesthesiology1987;67:806.
66.
UrmeyWF. Accuracy of expired carbon dioxide partial pressure sampled from a nasal cannula. I (letter). Anesthesiology1988;68:959–960.
67.
BonsuAK, TamilarasanA, BromagePR. A nasal catheter for monitoring tidal carbon dioxide in spontaneously breathing patients (letter). Anesthesiology1989;71:318.
68.
DunphyJA. Accuracy of expired carbon dioxide partial pressure sampled from a nasal cannula. II (letter). Anesthesiology1988;68:960–961.
69.
GoldmanJA. Accuracy of expired carbon dioxide partial pressure sampled from a nasal cannula. Reply (letter). Anesthesiology1988;68:961–962.
70.
McNultySE, TorjmanM, RoyJ, SaltzerJL. Correlation between arterial carbon dioxide and end tidal carbon dioxide using a nasal sampling port (abstract). Anesthe-siology1989;71:A355.
71.
RoyJ, McNultySE, TorjmanM.An improved nasal prong apparatus for end-tidal carbon dioxide monitoring in the awake sedated patient (abstract). Anesthesiology1989;71:A356.
72.
AckermanWE, JunejaMM, ReaumeD.Measurement of etCO2 and respiratory rate from a nasal cannula during cesarean section (abstract). Anesthesiology1989;71:A976.
73.
ChambersJB, KiffPJ, GardnerWN, JacksonG, BassC.Value of measuring end tidal partial pressure of carbon dioxide as an adjunct to treadmill exercise testing. Br Med J1988;296:1281–1285.
74.
SeveringhausJW, StupfelMA, BradleyAF. Alveolar dead space and arterial to end-tidal carbon dioxide differences during hypothermia in dog and man. J Appl Physiol1967;10:349–355.
75.
FletcherR, JonsonB, CummingG.The concept of deadspace with special reference to the single breath test for carbon dioxide. Br J Anaesth1981;53:77–88.
76.
YamanakaMK, SueDY. Comparison of arterial-end-tidal PCO₂ difference and dead space/tidal volume ratio in respiratory failure. Chest1987;92:832–835.
77.
PoppiusH, KorhonenO, KreusKE. Arterial to end-tidal CO2 difference in respiratory disease. Scand J Respir Dis1975;56:254–262.
78.
BermudezJ, LichtigerM.Increases in arterial to end-tidal CO2 tension differences after cardiopulmonary bypass. Anesth Analg1987;66:690–692.
79.
JulianDG, TravisDM, RobinED, CrumpCH. Effect of pulmonary artery occlusion upon end-tidal CO2 tension. J Appl Physiol1960;15:87–91.
80.
SchullerJL, BovillJG, NijveldA.End-tidal carbon dioxide concentration as an indicator of pulmonary blood flow during closed heart surgery in children. Br J Anaesth1985;57:1257–1259.
81.
HeneghanCPH, ScallanMJH, BranthwaiteMA. End-tidal carbon dioxide during thoracotomy: Its relation to blood level in adults and children. Anaesthesia1981;36:1017–1021.
82.
RobinED, JulianDG, TravisDM, CrumpCH. A physiologic approach to the diagnosis of acute pulmonary embolism. N Engl J Med1959;260:586–591.
83.
NutterDO, MassumiRA. The arterial-alveolar carbon dioxide tension gradient in diagnosis of pulmonary embolus. Dis Chest1966;50:380–387.
84.
HatleL, RoksethR.The arterial to end-expiratory carbon dioxide tension gradient in acute pulmonary embolism and other cardiopulmonary diseases. Chest1974;66:352–357.
85.
ErikssonL, WollmerP, OlssonC, . Diagnosis of pulmonary embolism based upon alveolar dead space analysis. Chest1989;96:357–362.
86.
ByrickRJ, KayJC, MullenJB. Capnography is not as sensitive as pulmonary artery pressure monitoring in detecting marrow microembolism. Anesth Analg1989;68:94–100.
87.
BirminghamPK, CheneyFW, WardRJ. Esophageal intubation: A review of detection of techniques. Anesth Analg1986;65:886–891.
88.
ConrardyPA, GoodmanLR, LaingeF, SingerMM. Alteration of endotracheal tube position: Flexation and extension of the neck. Crit Care Med1976;4:7–12.
89.
MurrayIP, ModellJH. Early detection of endotracheal tube accidents by monitoring carbon dioxide concentration in respiratory care. Anesthesiology1983;59:344–346.
90.
LinkoK, PaloheimoM, TammistoT.Capnography for detection of accidental oesophageal intubation. Acta Anaesthiol Scand1983;27:199–202.
91.
GuggenbergerH, LenzG, FederleR.Early detection of inadvertent oesophageal intubation: Pulse oximetry vs capnography. Acta Anaesthesiol Scand1989;33:112–115.
92.
ZbindenS, SchupferG.Detection of oesophageal intubation: The cola complication (letter). Anesthesia1989;44:81.
93.
GarnettAR, GervinCA, GervinAS. Capnographic wave-forms in esophageal intubation: Effect of carbonated beverages. Ann Emerg Med1989;18:387–390.
94.
OwenRL, CheneyFW. Use of an apnea monitor to verify endotracheal intubation. Respir Care1985;30:974–976.
95.
MarriottWM. The determination of alveolar carbon dioxide tension by a simple method. JAMA1916;66:1594–1596.
96.
SmithRH, VolpittoPP. Simple method of determining CO2 content of alveolar air (letter). Anesthesiology1959;20:702–703.
97.
BermanJA, FurgiueleJJ, MarxGF. The Einstein carbon dioxide detector (letter). Anesthesiology1984;60:613–614.
KingH, WootenDJ. Blind nasal intubation by monitoring end-tidal CO2 (letter). Anesth Analg1989;69:412–413.
102.
GeraldJ, MacLeodBA, HellerMB, YealyDM. Verification of endotracheal intubation using a disposable end-tidal CO2 detector (abstract). Prehospital and Disaster Medicine1989;4:74.
103.
O'CallaghanJP, WilliamsRT. Confirmation of tracheal intubation using a chemical device (abstract). Can J Anaesth1988;35:S59.
104.
HessD, RuppertT, McClureS.A bench evaluation of the FEF end-tidal CO2 detector (abstract). Respir Care1989;34:1047–1048.
105.
SayahAJ, PeacockWF, OvertonDT. Value of end-tidal CO₂ measurement in the detection of esophageal intubation during cardiac arrest (abstract). Ann Emerg Med1989;18:459.
106.
SealyWC, OginoS, LesageAM, YoungWG. Functional and structural changes in the lung in hemorrhagic shock. Surg Gynecol Obstet1966;122:754–760.
107.
AyresSM, MuellerH, GianneliiS, FlemingP, GraceWJ. The lung in shock: Alveolar-capillary gas exchange in the shock syndrome. Am J Cardiology1970;26:588–594.
108.
WeilMH, BiseraJ, TrevinoRP, RackowEC. Cardiac output and end-tidal carbon dioxide. Crit Care Med1985;13:907–909.
109.
TrevinoRP, BiseraJ, WeilMH, RackowEC, GrundlerWG. End-tidal CO2 as a guide to successful cardiopul-monary resuscitation: A preliminary report. Crit Care Med1985;13:910–911.
110.
GudipatiC, WeilMH, BiseraJ, DeshmukhHG, RackowEC. Expired carbon dioxide: A noninvasive monitor of cardiopulmonary resuscitation. Circulation1988;77:234–239.
111.
SandersAB, AltasM, EwyGA, KernKB, BraggS.Expired PCO₂ as an index of coronary perfusion pressure. Am J Emerg Med1985;3:147–149.
112.
SandersAB, EwyGA, BraggS, AtlasM, KernKB. Expired PCO₂ as a prognostic indicator of successful resuscitation from cardiac arrest. Ann Emerg Med1985;14:948–952.
113.
KalendaZ.The capnogram as a guide to the efficacy of cardiac massage. Resuscitation1978;6:259–263.
FalkJL, RackowEC, WeilMH. End-tidal carbon dioxide concentration during cardiopulmonary resuscitation. N Engl J Med1988;318:607–611.
116.
SandersAB, KernKB, OttoCW, MilanderMM, EwyGA. End-tidal carbon dioxide monitoring during cardiopulmonary resuscitation: A prognostic indicator for survival. JAMA1989;262:1347–1351.
117.
OrnatoJP, GonzalezER, GarnettR, LevineRL, McClungBK. Effect of cardiopulmonary resuscitation compression rate on end-tidal carbon dioxide concentration and arterial pressure in man. Crit Care Med1988;16:241–245.
118.
OrnatoJP, LevineRL, YoungDS, RachtEM, GarnettAR, GonzalezER. The effect of applied chest compression force on systemic arterial pressure and end-tidal carbon dioxide concentration during CPR in human beings. Ann Emerg Med1989;18:732–737.
119.
LepilinMG, VasilyevAV, BildinovOA, RostovtsevaNA. End-tidal carbon dioxide as a noninvasive monitor of circulatory status during cardiopulmonary resuscitation. Crit Care Med1987;15:958–959.
120.
WardKR, SullivanRJ, ZelenckRR, SummerWR. A comparison of interposed abdominal compression CPR and standard CPR by monitoring end-tidal PCO2. Ann Emerg Med1989;18:831–837.
121.
EpsteinMF, CohenAR, FeldmanHA, RaemerDB. Esti-mation of PaCO2 by two noninvasive methods in the critically ill newborn infant. J Pediatr1985;106:282–286.
122.
WatkinsAMC, WeindlingAM. Monitoring of end tidal CO2 in neonatal intensive care. Arch Dis Child1987;62:837–839.
123.
HandIL, ShepardEK, KraussAN, AuldAM. Discrepancies between transcutaneous and end-tidal carbon dioxide monitoring in the critically ill neonate with respiratory distress syndrome. Crit Care Med1989;17:556–559.
124.
McEvedyBAB, McLeodME, MuleraM, KirpalaniH, LermanJ.End-tidal, transcutaneous, and arterial PCO2 measurements in critically ill neonates: A comparison study. Anesthesiology1988;69:112–116.
125.
EvansJM, HoggIJ, RosenM.Correlation of alveolar PCO₂ estimated by infra-red analysis and arterial PCO₂ in the human neonate and the rabbit. Br J Anaesth1977;49:761–764.
126.
LindahlSG, YatesAP, HatchDJ. Relationship between invasive and noninvasive measurements of gas exchange in anesthetized infants and children. Anesthesiology1987;66:168–175.
127.
MenyRG, BhatAM, AranasE.Mass spectrometer monitoring of expired carbon dioxide in critically ill neonates. Crit Care Med1985;13:1064–1068.
128.
NelsonNM, Prod'homLS, CherryRB, LipsitzPJ, SmithCA. Pulmonary function in the newborn infant. I. Methods: Ventilation and gaseous metabolism. Pediatrics1962;30:963–974.
129.
ValentinN, LomholtB, ThorupM.Arterial to end-tidal carbon dioxide tension difference in children under halothane anesthesia. Can Anaesth Soc J1982;29:12–15.
130.
FletcherR.Invasive and noninvasive measurement of the respiratory deadspace in anesthetized children with cardiac disease. Anesth Analg1988;67:442–447.
131.
BurrowsFA. Physiologic dead space, venous admixture, and the arterial to end-tidal carbon dioxide difference in infants and children undergoing cardiac surgery. Anesthesiology1989;70:219–225.
132.
CoteCJ, SzyfelbeinSK, GoudsouzianNG, WelchJP. Intraoperative events diagnosed by expired carbon dioxide monitoring in children. Can Anaesth Soc J1986;33:315–320.
133.
DumpitFM, BradyJP. A simple technique for measuring alveolar CO2 in infants. J Appl Physiol1978;45:648–650.
134.
PascucciRC, SchenaJA, ThompsonJE. Comparison of a sidestream and mainstream capnometer in infants. Crit Care Med1989;17:560–562.
135.
SasseFJ. Can we trust end-tidal carbon dioxide measurements in infants (editorial)?J Clin Monit1985;1:147–148.
136.
SchieberRA, NamnoumA, SugdenA, SavilleAL, OrrRA. Accuracy of expiratory carbon dioxide measurements using the coaxial and circle breathing circuits in small subjects. J Clin Monit1985;1:149–155.
137.
GravensteinN.Capnometry in infants should not be done at lower sampling flow rates (letter). J Clin Monit1989;5:63.
138.
BadgwellJM, McLeodME, LermanJ, CreightonRE. End-tidal PCO2 measurements sampled at the distal and proximal ends of the endotracheal tube in infants and children. Anesth Analg1987;66:959–964.
139.
MeredithKS, MonacoF.End tidal carbon dioxide (PetCO2) monitoring in the intensive care nursery (abstract). Crit Care Med1989;17:S106.
140.
HillierSC, LermanJ.Mainstream vs sidestream capnography in anesthetized infants and children (abstract). Anesthesiology1989;71:A357.
141.
RichGF, SullivanMP, AdamsJM. Is distal sampling of end tidal CO2 necessary in small subjects (abstract)?Anesthesiology1989;71:A1005.
142.
McNabbL, GlobersonT, St. ClairR, WilsonAF. The arterial-end tidal PCO₂ difference in patients on ventilators (abstract). Chest1981;80:381.
143.
HealeyCJ, FedulloAJ, SwinburneAJ, WahlGW. Comparison of noninvasive measurements of carbon dioxide tension during withdrawal from mechanical ventilation. Crit Care Med1987;15:764–768.
144.
NiehoffJ, DelGuercioC, LaMorteW, . Crit Care Med1988;16:701–705.
145.
ThrushDN, WayneS, DownsJB. Weaning without blood gases: A possibility (abstract). Anesthesiology1989;71:A208.
146.
WeingerMB, BrimmJE. End-tidal carbon dioxide as a measure of arterial carbon dioxide during intermittent mandatory ventilation. J Clin Monit1987;3:73–79.
147.
SmithRA, NovakRA, VenusB.End-tidal CO2 monitoring utility during weaning from mechanical ventilation. Respir Care1989;34:972–975.
148.
MurrayIP, ModellJH, GallagherTJ, BannerMJ. Titration of PEEP by the arterial minus end-tidal carbon dioxide gradient. Chest1984;85:100–104.
149.
JardinF, GenevrayB, PazinM, MargairazA.Inability to titrate PEEP in patients with acute respiratory failure using end-tidal carbon dioxide measurements. Anesthesi-ology1985;62:530–533.
150.
BlanchL, FernandezR, BenitoS, ManceboJ, NetA.Effect of PEEP on the arterial minus end-tidal carbon dioxide gradient. Chest1987;92:451–454.