KreskyB.Control of gram-negative bacilli in a hospital nursery. Am J Dis Child. 1964;107:363–369.
2.
ReinarzJA, PierceAK, MaysBB, SanfordJP. The potential role of inhalation therapy equipment in nosocomial pulmonary infections. J Clin Invest. 1965;44:831–839.
3.
BassettCDJ, ThompsonSAS, PageB.Neonatal infections with Pseudomonas aeruginosa associated with contaminated resuscitation equipment. Lancet. 1965;1:781–784.
4.
MertzJJ, ScharerL, McClementJH. A hospital outbreak of Klebsiella pneumonia from inhalation therapy with contaminated aerosol solution. Am Rev Respir Dis. 1966;94:454–460.
5.
FiererJ, TaylorPM, GezonHM. Pseudomonas aeruginosa epidemic traced to delivery-room resuscitators. N Engl J Med. 1967;276:991–996.
6.
McNamaraMJ, HillMC, BalowsA, et al. A study of the bacteriologic patterns of hospital infections. Ann Intern Med. 1967;66:480–487.
7.
MoffetHL, AllanD.Colonization of infants exposed to bacterially contaminated mists. Am J Dis Child. 1967;114:21–25.
8.
RingroseRE, McKownB, FeltonFG, et al. A hospital outbreak of Serratia marcescens associated with ultrasonic nebulizers. Ann Intern Med. 1968;69:719–729.
9.
CabreraHA. An outbreak of Serratia marcescens and its control. Arch Intern Med. 1969;123:650–655.
10.
GriebleHG, ColtonFR, BirdTJ, et al. Fine-particle humidifiers: Source of Pseudomonas aeruginosa infections in a respiratory-disease unit. N Engl J Med. 1970;282:531–534.
11.
SandersCVJr, LubyJP, JohansonWGJr, et al. Serratia marcescens infections from inhalation therapy medications: Nosocomial outbreak. Ann Intern Med. 1970;73:15–21.
12.
PierceAK, SanfordJP. Bacterial contamination of aerosols. Arch Intern Med. 1973;13:156–159.
Anonymous. Bacteria in antiseptic solutions. Br Med J. 1958;2:436.
25.
LeeJC, FialkowPJ. Benzalkonium chloride: Source of hospital infection with gram-negative bacteria. JAMA. 1961;177:708–710.
26.
MaliziaWF, GangarosaEJ, GoleyAF. Benzalkonium chloride as a source of infection. N Engl J Med. 1960;263:800–802.
27.
PlotkinSA, AustrianR.Bacteremia caused by Pseudomonas sp following the use of materials stored in solutions of a cationic surface-active agent. Am J Med Sci. 1958;238:621–627.
Anonymous. Failure of detergents to disinfect. Lancet. 1958;2:306.
30.
Anonymous. Disinfectants and gram-negative bacteria. Lancet. 1972;1:26–27.
31.
BurdonDW, WhitbyJL. Contamination of hospital disinfectants with Pseudomonas species. Br Med J. 1967;1:153–155.
32.
EdgeRS. Infection control. In: BainesTA, LisbonA.Respiratory care practice. Chicago: Year Book Medical Publishers; 1988:573–562.
33.
SchniersonSS. Sterilization by heat. Int Anesthesiol Clin. 1972;10(2):67–83.
34.
KacmarekRM, MackCW, DimasS.The essentials of respiratory therapy. 2nd ed. Chicago: Year Book Medical; 1985:584.
35.
ArtandiC.Sterilization by ionizing radiation. Int Anesthesiol Clin. 1972;10(2):123–130.
36.
FaveroMS. Chemical disinfection of medical and surgical materials. In: BlockSS, ed. Disinfection, sterilization and preservation. 3rd ed. Philadelphia: Lea & Febiger; 1983:469–492.
WilsonRD, TraberDL, AllenCR, PrianoLL, BassJ.An evaluation of the Cidematic decontamination system for anesthesia equipment. Anesth Analg. 1972;51:658–661.
39.
BorickPM, DondershineFH, HollisRA. A new automated unit for cleaning and disinfecting anesthesia equipment and other medical instruments. Dev Ind Microbiol. 1971;12:266–272.
40.
IddendenFR. New decontamination procedure cuts costs, reduces staff time. Can Hosp. 1972;49:26–28.
41.
ChatburnRL, KallstromTJ, BajaksouzianMS. A comparison of acetic acid with a quaternary ammonium compound for disinfection of hand-held nebulizers. Respir Care. 1988;33:179–187.
42.
O'RyanJ, BurnsD.Pulmonary rehabilitation: From hospital to home. Chicago: Year Book Medical; 1984:227–229.
43.
BlodgettD.Manual of respiratory care procedures. Philadelphia: JB Lippincott; 1987:308–310.
44.
ZimentI.Pharmacology of drugs used in respiratory therapy. In: BurtonGG, GeeGN, HodgkinJE, eds. Respiratory care: A guide to clinical practice. Philadelphia: JB Lippincott; 1977:493.
45.
EdmondsonE, ReinarzJ, PierceAK, SanfordJ.Nebulization equipment: A potential source of infection in gram-negative pneumonia. Am J Dis Child. 1966;3:357–360.
46.
RhoadesE, RingroseR, MohrJ, BrooksL, McKownB, FeltonF.Contamination of ultrasonic nebulization equipment with gram-negative bacteria. Arch Intern Med. 1971;127:228–232.
47.
BrockTD. Biology of microorganisms. Englewood Cliffs NJ: Prentice Hall; 1970:213–214.
48.
SpaldingEH. Principles and application of chemical disinfection. Association of Operating Room Nurses J. 1963;1:36–46.
49.
SpauldingEH. Chemical disinfection and antisepsis in the hospital. J Hosp Res. 1972;9:7–31.
50.
AyliffeGAJ. Hospital disinfection and antibiotic policies. Chemotherapy. 1987;6:228–233.
51.
RobertsFJ, CockcroftWH, JohnsonHE. A hot water disinfection method for inhalation therapy equipment. Can Med Assoc J. 1969;101:30–32.
52.
NelsonEJ, RyanKJ. A new use for pasteurization: Disinfection of inhalation therapy equipment. Respir Care. 1971;16:97–103.
53.
HaradaS, YoshiyamaH, YamamotoN.Effect of heat and fresh human serum on the infectivity of human T-cell lymphotropic virus type III evaluated with new bioassay systems. J Clin Microbiol. 1985;22:908–911.
54.
GarnerJS, FaveroMS. CDC guidelines for the prevention and control of nosocomial infections: Guideline for handwashing and hospital environmental control, 1985. Am J Infect Control. 1986;14:110–129.
55.
ErnstRR. Sterilization by heat. In: BlockSS. Disinfection, sterilization and preservation. Philadelphia: Lea & Febiger; 1977:494.
56.
BorikPM. Chemical sterilizers (chemosterilizers). Adv Appl Microbiol. 1968;10:291–312.
57.
BorikPM, DondershineFH, ChandlerVL. Alkalinized glutaraldehyde, a new antimicrobial agent. J Pharm Sci. 1964;53:1273–1275.
58.
BorikPM. Antimicrobial agents as liquid chemosterilizers. Biotechnol Bioeng. 1965;7:435–443.
HaselhuhnDH, BrasonFW, BorickPM. "In use" study of buffered glutaraldehyde for cold sterilization of anesthesia equipment. Anesth Analg. 1967;46:468–474.
RobertsRB. The anaesthetist, cross-infection and sterilization techniques: A review. Anaesth Intensive Care. 1973;1:400–406.
63.
SnyderRW, CheatleEL. Alkaline glutaraldehyde as effective disinfectant. Am J Hosp Pharm. 1965;22:321–327.
64.
StonehillAA, KropS, BorickPM. Buffered glutaraldehyde, a new chemical sterilizing solution. Am J Hosp Pharm. 1963;20:458–465.
65.
FisherAA. Reactions to glutaraldehyde with particular reference to radiologists and x-ray technicians. Cutis. 1981;28:113,114,119.
66.
BelaniKG, PriedkalnsJ.An epidemic of pseudomem-branous laryngotracheitis. Anesthesiology. 1977;47:530–531.
67.
BoucherRMG. Cidex and Sonacide compared. Respir Care. 1977;22:790–799.
68.
Medical Research Council. Sterilization by steam under increased pressure. Lancet. 1959;1:425–435.
69.
Rendell-BakerL, RobertsRB. Gas versus steam sterilization: When to use which. Med Surg Rev. 1969;4th Quarter:10–14.
70.
HoytA, ChaneyAL, CavellK.Studies on steam sterilization and the effects of air in the autoclave. J Bacteriol. 1938;36:639–652.
71.
FallonRJ. Factors concerned in the efficient steam sterilization of surgical dressings. J Clin Pathol. 1961;14:505–511.
72.
KretzAP. High vacuum sterilization. Association of Operating Room Nurses J. 1964;2:35–40.
73.
Rendell-BakerL.Ethylene oxide. II. Aeration. Int Anesthesiol Clin. 1972;10:101–122.
74.
American National Standards Institute Sectional Committee Z-79 and ASA Subcommittee on Standardization. Ethylene oxide sterilization of anesthesia apparatus. Anesthesiology. 1970;33:120.
75.
AndersonSR. Ethylene oxide residues in medical materials. Bull Parenteral Drug Assoc. 1973;27:49–57.
76.
Association for the Advancement of Medical Instrumen-tation. Good hospital practice: Ethylene oxide gas-ventilation recommendations and safe use. AAMI DO-VRSU. 1981.
77.
LiptonB, GutierrezR, BlaugrundS, LitwakRS, Rendell-BakerL.Irradiated PVC plastic and gas sterilization in the production of tracheal stenosis following tracheostomy. Anesth Analg. 1971;50:578–586.
78.
RoyceA, MooreWKS. Occupational dermatitis caused by ethylene oxide. Br J Ind Med. 1955;12:169–171.
79.
PoothullilJ, ShimizuA, DyRO, DolovichJ.Anaphylaxis from the product(s) of ethylene oxide gas. Ann Intern Med. 1975;82:58–60.
O'LearyRK, GuessWL. The toxiogenic potential of medical plastics sterilized with ethylene oxide vapors. J Biomed Mater Res. 1968;2:297–311.
82.
HiroseT, GoldsteinR, BaileyCP. Hemolysis of blood due to exposure to different types of plastic tubing and the influence of ethylene oxide sterilization. J Thorac Cardiovasc Surg. 1963;45:245–251.
83.
RobertsRB. Gamma rays + PVC + EO = OK. Respir Care. 1976;21:223–224.
84.
StetsonJB, WhitbourneJE, EastmanC.Ethylene oxide degassing of rubber and plastic materials. Anesthesiology. 1976;44:174–180.
85.
BogdanskyS, LehnPJ. Effects of gamma-irradiation on 2-chloro-ethanol formation in ethylene oxide-sterilized polyvinyl chloride. J Pharm Sci. 1964;63:802–803.
86.
BrysonTK, SaidmanLJ, NelsonW.A potential hazard connected with the resterilization and reuse of disposable equipment. Anesthesiology. 1979;50:370.
87.
GrossJA, HaasML, SwiftTR. Ethylene oxide neurotoxicity: Report of four cases and review of the literature. Neurology. 1979;29:978–983.
88.
GlaserZR. Special occupation hazard review with control recommendations for the use of ethylene oxide as a sterilant in medical facilities. U.S. Dept HEW DHEW (NIOSH), Publication No. 77-200, August 1977.
89.
U.S. Department of Health and Human Services, DHSS (NIOSH). NIOSH current intelligence bulletin 35: Ethylene oxide. Publication No. 81-130, May 22, 1981.
90.
CMP Publications. CMP Publications Health Week: The newspaper for America's health industry. Emoryville CA: 1987:1,6-7.
91.
SpectorGJ. Cleansing of endoscopic instruments to prevent spread of infectious disease (letter). Laryngoscope. 1987;97:887.
92.
Institute for Health Policy Analysis, Georgetown University Medical Center. Proceedings of international conference on the re-use of disposable medical devices in the 1980s, March 29-30, 1984. Washington DC: Institute for Health Policy Analysis; 1984.
93.
SimmonsBP, WongES. Guidelines for prevention of nosocomial pneumonia. Infect Control. 1982;3:327–333.
94.
GoularteTA, CravenDE. Results of a survey of infection control practices for respiratory therapy equipment. Infect Control. 1986;7:327–330.