PepePE, MariniJJ. Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction, the auto-PEEP effect. Am Rev Respir Dis1982;126:166–170.
2.
BergmanNA. Pulmonary gas trapping during mechanical ventilation at rapid frequencies. Anesthesiology1972;37:626–633.
3.
RossiA, GottfriedSB, ZocchiL, et al. Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation: The effect of intrinsic positive-end expiratory pressure. Am Rev Respir Dis1985;131:672–677.
4.
TuxenDV, LaneS.Determinants of pulmonary hyperinflation in mechanical ventilation of patients with severe airflow obstruction (abstract). Crit Care Med1986;14:367.
5.
ScottLR, BensonMS, BishopMJ. Relationship of endotracheal tube size to auto-PEEP at high minute ventilation. Respir Care1986;31:1080–1082.
6.
BrownDG, PiersonDJ. Auto-PEEP is common in mechanically ventilated patients: A study of incidence, severity, and detection. Respir Care1986;31:1069–1074.
7.
BarachAL, EckmanM, GinsburgE, et al. Studies on positive pressure respiration: (I) General aspects of pressure breathing. (II) Effects on respiration and circulation at sea level. J Aviat Med1946;17:290–380.
8.
LuceJ.The cardiovascular effects of mechanical ventilation and positive end-expiratory pressure. JAMA1984;252:807–811.
9.
O'QuinR, MariniJJ. Pulmonary artery occlusion pressure: Clinical physiology, measurement and interpretation. Am Rev Respir Dis1983;128:319–325.
10.
QvistJ, PontoppidanH, WilsonR, LowensteinE, LaverM.Hemodynamic responses to mechanical ventilation with PEEP: The effect of hypervolemia. Anesthesiology1975;42:45–55.
11.
ZarinsC, VirgillioR, SmithD, PetersR.The effect of vascular volume on positive end-expiratory pressure-induced cardiac output depression and wedge left atrial pressure discrepancy. J Surg Res1977;23:348–360.
12.
ChapinJC, DownsJB, DouphyEJ, RuizBC. Lung expansion, pressure transmission and positive end expiratory pressure. Arch Surg1979;114:110–116.
13.
SmithTC, MariniJJ, LambVJ. The inspiratory threshold load resulting from air-trapping during mechanical ventilation (abstract). Am Rev Respir Dis1987;135(4, Part 2):A52.
14.
SmithTC, MariniJJ, LambVJ. The effect of PEEP on auto-PEEP (abstract). Chest1986;89:443S.
15.
BoneRC. Monitoring respiratory function in the patient with the adult respiratory distress syndrome. In: DeckerBC, ed. Semin Respir Med1981;2:140–150.
16.
PiersonDJ. Alveolar rupture during mechanical ventilation: Role of PEEP, peak airway pressure, and distending volume. Respir Care1988;33:472–486.
17.
ScottLR, BensonMS, PiersonDJ. Effect of inspiratory flowrate and circuit compressible volume on auto-PEEP during mechanical ventilation. Respir Care1986;31:1075–1079.
18.
ConnorsAF, McCaffreeDR, GrayBA. Effect of inspiratory flowrate on gas exchange during mechanical ventilation. Am Rev Respir Dis1981;124:537–543.
19.
FeltonCR, MontenegroHD, SaidelGM. Inspiratory flow effects on mechanically ventilated patients: Lung volume, inhomogeneity and arterial oxygenation. Intensive Care Med1984;10:281–286.
GayPC, RodarteJR, HubmayrRD. The effect of extrinsic PEEP on lung volume, isovolume flow and respiratory work in dynamically hyperinflated patients (abstract). Am Rev Respir Dis1987;135(4, Part 2):A52.
22.
ConoscentiC, MenasheP, ReardonE, et al. Effect of positive end expiratory pressure on intrinsic PEEP in acute respiratory failure (abstract). Chest1986;89:443S.
23.
QvistJ, AndersenJB, PembertonM, BenkleKA. High-level PEEP in severe asthma (letter). N Engl J Med1982;307:1347–1348.
24.
RoubyJJ, FusciardiJ, BourgainJL, ViarsP.High-frequency jet ventilation in postoperative respiratory failure: Determinants of oxygenation. Anesthesiology1983;59:281–287.
25.
BenhamovD, EcoffeyC, RoubyJJ, FusciardiJ, ViarsP.Impact of changes in operating pressure during high-frequency jet ventilation. Anesth Analg (Cleve)1984;63:19–24.
26.
RoubyJJ, FusciardiJ, BourgainJL, ViarsP.Factors influencing pulmonary volumes and CO2 elimination during high-frequency jet ventilation. Anesthesiology1985;63:473–482.
27.
BeamerWC, ProughDS, RoysterRL, et al. High-frequency jet ventilation produces auto-PEEP. Crit Care Med1984;12:734–737.
28.
GurevichM, Van DykeJV, YoungES, JacksonK.Improved oxygenation and lower peak airway pressure in severe adult respiratory distress syndrome: Treatment with inverse ratio ventilation. Chest1986;89:211–213.
29.
ConoscentiC, MenasheP, MeduriGU, GottleibJ.Intrinsic PEEP during inverse ratio ventilation (abstract). Am Rev Respir Dis1987;135(4, Part 2):A55.
30.
DuncanSR, RizkNW, RaffinTA. Inverse ratio ventilation, PEEP in disguise? (letter). Chest1987;92:390–392.