TookerJ, HusebyJ, ButlerJ.The effect of Swan-Ganz catheter height on the wedge pressure-left atrial pressure relationship in edema during positive pressure ventilation. Am Rev Respir Dis1978;117:721–726.
2.
ChulayM, MillerT.The effect of backrest elevation on pulmonary artery and pulmonary capillary wedge pressure in patients after cardiac surgery. Heart Lung1984;13(2):138–140.
3.
WoodsSL, MansfieldLW. Effect of body position upon pulmonary artery and pulmonary capillary wedge pressure in non-critically ill patients. Heart Lung1976;5:83–90.
4.
PatelDJ, MasonDT, RossJJr, BraunwaldE.Harmonic analysis of pressure pulses obtained from the heart and great vessels of man. Am Heart J1965;69:785–794.
5.
FryDL. Physiologic recording by modern instruments with particular reference to pressure recording. Physiol Rev1960;40:753–788.
6.
MortonBC. Basic equipment requirements for hemody-namic monitoring. Can Med Assoc J1979;121:879–885.
7.
GardnerRM. Direct blood pressure measurement. Dynamic response requirements. Anesthesiology1981;54:227–236.
8.
GardnerRM, WarnerHR, TorontoAF, GaisfordWD. Catheter flush system for continuous monitoring of central arterial pulse waveform. J Appl Physiol1970;29(6):911–913.
9.
MorrisAH, ChapmanRH, GardnerRM. Frequency of technical problems encountered in the measurement of pulmonary artery wedge presure. Crit Care Med1984;12(3):164–170.
10.
ShinB, McAslanTC, AyellaRJ. Problems with measure-ment using the Swan-Ganz catheter. Anesthesiology1975;43:474–476.
11.
ArcherG, CobbLA. Long term pulmonary artery pressure monitoring in the management of the critically ill. Ann Surg1974;180(5):747–752.
12.
WestJB, DolleryCT, NaimarkA.Distribution of blood flow in isolated lung; relation to vascular and alveolar pressures. J Appl Physiol1964;19:713–724.
13.
ShasbyDM, DauberIM, PfisterS, . Swan Ganz catheter location and left atrial pressure determine the accuracy of the wedge pressure when positive end-expiratory pressure is used. Chest1981;80:666–670.
HasanFM, MalangaAL, BramanSS, CorraoWM, MostAS. Lateral position improves wedge-left atrial pressure correlation during positive pressure ventilation. Crit Care Med1984;12(11):960–964.
17.
HasanFM, WeissWB, BramanSS, HoppinFGJr. Influence of lung injury on pulmonary wedge-left atrial pressure correlation during PEEP ventilation. Am Rev Respir Dis1985;131:246–250.
18.
FishmanAP. Dynamics of the pulmonary circulation. In: HamiltonWF, DonP, . Handbook of physiology. Section 2, Volume II, Circulation. Washington DC: American Physiological Society, 1963:1687.
19.
ForresterJS, DiamondG, McHughTJ, SwanHJC. Filling pressures in the right and left sides of the heart in acute myocardial infarction. A reappraisal of CVP monitoring. N Engl J Med1971;285:190–193.
20.
JenkinsBS, BradleyRD, BrathwaiteMA. Evaluation of pulmonary artery end-diastolic pressure as an indirect estimate of left atrial mean pressure. Circulation1970;42:75–78.
21.
CalvinJE, DriedgerAA, SibbaldWJ. The hemodynamic effect of rapid fluid infusion in critically ill patients. Surgery1981;90:61–76.
22.
O'QuinR, MariniJJ. Pulmonary artery occlusion pressure: Clinical physiology, measurement and interpretation. Am Rev Respir Dis1983;128:319–326.
23.
BaydurA, BehrakisPK, ZinWA, JaegerM, Milic-EmiliJ.A simple method for assessing the validity of the esophageal balloon technique. Am Rev Respir Dis1982;126:788–791.
24.
GillespieDJ. Comparison of intra-esophageal balloon pressure measurements with a nasogastric-esophageal balloon system in volunteers. Am Rev Respir Dis1982;126:583–585.
25.
MariniJJ, O'QuinR, CulverBH, ButlerJ.Estimation of transmural cardiac pressures during ventilation with PEEP. J Appl Physiol1982;53:384–391.
26.
MariniJJ, CulverBH, ButlerJ.Effect of positive end-expiratory pressure on canine ventricular function curves. J Appl Physiol1981;51(6):1367–1374.
27.
LloydTCJr. Respiratory system compliance as seen from the cardiac fossa. J Appl Physiol1982;53:57–62.
28.
DavisonR, ParkerM, HarrisonRA. The validity of determinations of pulmonary wedge pressure during mechanical ventilation. Chest1978;73:352–355.
29.
LaBrousseJ, TenaillonA, MassabieP, SimonneayG, LissacJ.Artifical ventilation and pulmonary capillary wedge pressure in acute respiratory failure (letter). Lancet1976;1:974.
30.
CarterRS, SnyderJV, PinskyMR. Pop-off wedge pressure as a reflection of left ventricular filling pressure (abstract). Crit Care Med1984;12(3):297.
31.
PepePE, MariniJJ. Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction. Am Rev Respir Dis1982;126:166–170.
32.
BerryhillRE, BenumofJL, RauscherLA. Pulmonary venous pressure reading at the end of exhalation. Anesthesiology1978;49:365–368.
33.
SchusterDP, SeemanMD. Temporary muscle paralysis for accurate measurement of pulmonary artery occlusion pressure. Chest1983;84:593–597.
34.
MariniJJ. Respiratory medicine and intensive care for the houseofficer. Baltimore: Williams and Wilkins, 1981:164.
35.
MaranAG. Variables in pulmonary capillary wedge pressure: Variation with intrathoracic pressure, graphic and digital recorders. Crit Care Med1980;8:102–105.
36.
CengizM, CrapoRO, GardnerRM. The effect of ventilation on the accuracy of pulmonary artery and wedge pressure measurements. Crit Care Med1983;11(2):502–507.
37.
MariniJJ, CappsJS, CulverBH. Inspiratory work of breathing during assisted mechanical ventilation. Chest1985;87:612–618.
38.
SilvermanH, EpplerJ, PitmanA, PatzD.Measurements of pulmonary capillary wedge pressure from graphic and digital recorders (abstract). Chest1984;86(2):335.
39.
SibbaldWJ, CalvinJ, DriedgerAA. Right and left ventricular preload and diastolic ventricular compliance. Implications for therapy in critically ill patients. In: Critical Care. Vol III. Fullerton CA: Society of Critical Care Medicine, 1982;III(F):1–33.
40.
LevettJM, ReplogleRL. Thermodilution cardiac output: A critical analysis and review of the literature. J Surg Res1978;27:392–404.
41.
StetzCW, MillerRG, KellyGE, RaffinTA. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis1982;126:1001–1004.
42.
RiedingerMS, ShellockFG. Technical aspects of the thermodilution method for measuring cardiac output. Heart Lung1984;13(3):215–222.
43.
NelsonLD, HoutchensBA. Automatic vs manual injections for thermodilution cardiac output determinations. Crit Care Med1982;10:190–192.
44.
WeilMH. Measurement of cardiac output. Crit Care Med1977;5(2):117–118.
45.
ArmengolJ, ManGCW, BalsysAJ, WellsAL. Effects of the respiratory cycle on cardiac output measurements: Reproducibility of data enhanced by timing the thermo-dilution injection in dogs. Crit Care Med1981;9(12):852–854.
46.
SnyderJV, PownerDJ. Effects of mechanical ventilation on the measurement of cardiac output by thermodilution. Crit Care Med1982;10:677–682.
SuterPM, LindauerJM, FairleyHB, SchlobohmRM. Errors in data derived from pulmonary artery blood gas values. Crit Care Med1975;3(5):175–181.
49.
KandelG, AbermanA.Mixed venous oxygen saturation. Its role in the assessment of the critically ill patient. Arch Intern Med1983;143:1400–1402.
50.
DantzkerDR. Mechanisms of hypoxemia and hypercarbia. In: Critical care: A comprehensive approach. Park Ridge IL: American College of Chest Physicians, 1984:1–14.
51.
DantzkerDR. The influence of cardiovascular function on gas exchange. Clin Chest Med1983;4(2):149–159.
52.
CheneyFW, ColleyPS. The effect of cardiac output on arterial blood oxygenation. Anesthesiology1980;52:496–503.
53.
ArmstrongRF, AndrewD, CohenSL, . Continuous monitoring of mixed venous oxygen tension (PVO2) in cardio-respiratory disorders. Lancet1978;1:632–634.
54.
BaelePL, McMichanJC, MarshHM, SillJC, SouthornPA. Continuous monitoring of mixed venous oxygen saturation in critically ill patients. Anesth Analg1982;61:513–517.
55.
DeCampoT, CivettaJM. The effect of short-term discontinuation of high-level PEEP in patients with acute respiratory failure. Crit Care Med1979;7:47–49.
56.
KumarA, FalkeKT, GeffinB, . Continuous positive pressure ventila-tion in acute respiratory failure. N Engl J Med1970;283:1430–1436.