GregoryGA, KittermanJA, PhibbsRH, . Treatment of the idiopathic respiratory distress syndrome with continuous positive airway pressure. N Engl J Med1971;284:1333–1340.
2.
HarrisonGA. Ayres T-piece: A review of its modification. Br J Anaesth1964;36:115–120.
3.
BentleyD, DeatonDW, AhlgrenEW. A device to deliver continuous positive airway pressure (CPAP) to infants. Respir Care1972;17:156,158,160,163.
4.
GargGP. Humidification of the Rees-Ayres T-piece system for neonates. Anesth Analg (Cleve)1973;52:207–209.
5.
PfitznerJ, BranthwaiteMA, EnglishCW, . Continuous positive airway pressure: A new system. Anaesthesia1974;29:326–334.
6.
MillerRH, SangreyGL. An improved device for CPPB in infants with respiratory distress. Respir Care1974;19:787–789.
7.
BenvenisteD, BergO, PedersonJE. A technique for delivery of continuous positive airway pressure to the neonate. J Pediatr1976;88:1015–1019.
BarrieH.Simple method of applying continuous positive airway pressure in respiratory-distress syndrome. Lancet1972;1:776–777.
10.
VertP, AndreM, SiboutM.Continuous positive airway pressure and hydrocephalus (letter). Lancet1973;2:319.
11.
KraussDR, MarshallRE. Severe neck ulceration from CPAP head box. Pediatrics1975;86:286–289.
12.
SvenningsenNW, BlennowG.Continuous positive airway pressure and noise level. Lancet1973;2:623–624.
13.
HarrisTR. Continuous positive airway pressure applied by face mask (abstract). Pediatr Res1972;6:410.
14.
AhlstromH, JonsonB, SvenningsenNW. Continuous positive pressure with a face chamber in early treatment of idiopathic respiratory distress syndrome. Acta Anaesthesiol Scand1973;62:433–436.
15.
RhodesPG, HallRT. Continuous airway pressure delivered by face mask in infants with the idiopathic respiratory distress syndrome: A controlled study. Pediatrics1973;52:17–21.
16.
AckermanBD, SteinMP, SommerJS, SchumacherM.Continuous positive airway pressure applied by means of a tight-fitting face-mask. J Pediatr1974;85:408–411.
17.
BannisterDG, HainesCI. Continuous positive airway pressure by facemask in newborn infants (letter). Br Med J1975;4:758.
18.
BelenkyDA, OrrRJ, WoodrumDE, HodsonWA. Is continuous transpulmonary pressure better than conventional respiratory management of hyaline membrane disease? A controlled study. Pediatrics1967;58:800–808.
19.
PapeKE, ArmstrongDL, FitzhardingePM. Central nervous system pathology associated with mask ventilation in the very low birthweight infant: A new etiology for intracerebellar hemorrhages. J Pediatr1976;58:473–483.
20.
AgostinoR, OrzalesiM, NodariS, . Continuous positive airway pressure (CPAP) by nasal cannula in the respiratory distress syndrome (RDS) of the newborn (abstract). J Pediatr1973;7:50.
21.
KattwinkelJ, FlemingD, ChaCC, FanaroffAA, KlausMH. A device for administration of continuous positive airway pressure by the nasal route. J Pediatr1973;52:131–133.
22.
RisembergHM, FomufodAK, HazelbakerN, NishidaH, PeralpaMJ. Assisted ventilation with nasal continuous positive airway pressure and its effects on morbidity and mortality in respiratory distress syndrome. Johns Hopkins Med J1974;135:171–177.
23.
HarrisH, BransY, WilsonS, CassidyS.Nasal end-expiratory pressure (NEEP) in the management of hyaline membrane disease (HMD) (abstract). Pediatr Res1974;8:477.
24.
KrouskopRW, BrownEG, SweetAY. The early use of continuous positive airway pressure in the treatment of idiopathic respiratory distress syndrome. J Pediatr1975;87:263–267.
25.
WungJT, DriscollJM, EpsteinRA, HymanAI. A new device for CPAP by nasal route. Crit Care Med1975;3:76–78.
VidyasagarD, ChernickV.Continuous positive transpulmonary pressure in hyaline membrane disease: A simple device. J Pediatr1971;48:296–299.
34.
ChernickV, VidyasagarD.Continuous negative chest wall pressure in hyaline membrane disease: One year experience. J Pediatr1972;49:753–760.
35.
OuterbridgeEW, RoloffDW, SternL.Continuous negative pressure in the management of severe respiratory distress syndrome. J Pediatr1972;81:384–391.
36.
BancalariE, GarciaOL, JesseMJ. Effects of continuous negative pressure on lung mechanics in idiopathic respiratory distress syndrome. J Pediatr1973;51:485–493.
37.
FanaroffAA, ChaCC, SosaR, CrumrineRS, KlausMH. Controlled trial of continuous negative external pressure in the treatment of severe respiratory distress syndrome. J Pediatr1973;51:485–493.
38.
BancalariE, GerhardtT, MonkusE.Simple device for producing continuous negative pressure in infants with IRDS. J Pediatr1973;52:128–131.
39.
BarachAL. Differences between CPPB and CNP are not significant (letter). Respir Care1978;23:124.
40.
MillerCR, SmithER, LytleJS, RogersRL. Experience with a chamber for continuous negative pressure treatment of infants with respiratory distress. Respir Care1977;22:931–934.
41.
CivettaJM, BronsR, GabelJC. A simple and effective method of employing spontaneous positive pressure ventilation. J Thorac Cardiovasc Surg1972;63:312–317.
42.
GargGP, HillGE. The use of spontaneous continuous positive airway pressure (CPAP) for reduction of intrapulmonary shunting in adults with acute respiratory failure. Can Anaesth Soc J1975;22:284–290.
43.
SpicerJ, MantleJ, MarottaJ.A new method for delivery of CPAP via the Bird respirator. Respir Care1976;21:987–990.
44.
OrtizAH, HerlihyJF. A portable PEEP/CPAP apparatus. Respir Care1976;21:168–169.
45.
VenusB, JacobsHK, LimL.Treatment of the adult respiratory distress syndrome with continuous positive airway pressure. Chest1979;76:257–261.
46.
RoseDM, DownsJB, HeenanTJ. Temporal responses of functional residual capacity and oxygen tension to changes in positive end-expiratory pressure. Crit Care Med1981;9:79–82.
47.
ZebrowskiME, GeerRT. Low flow continuous positive airway pressure with a modified fresh gas reservoir. Crit Care Med1981;9:106–108.
48.
ZamostBG, AlferyDD, JohansonI, GlazenerEL, TrousdaleFR, BenumofJL. Description and clinical evaluation of a new continuous positive airway pressure device. Crit Care Med1981;9:109–113.
49.
FriedJL, DownsJB, DavisJEP, HeenanTJ. A new venturi device for administering continuous positive airway pressure (CPAP). Respir Care1981;26:133–136.
50.
BarachAL. The use of helium in the treatment of asthma and obstructive lesions in the larynx and trachea. Ann Intern Med1935;9:739–764.
51.
PoultonEP, OxonDM. Left-sided heart failure with pulmonary edema. Lancet1936;2:981–983.
52.
GreenbaumDM, MillenJE, ErossB, SnyderJV, GrenvikA, SafarP.Continuous positive airway pressure without tracheal intubation in spontaneously breathing patients. Chest1976;69:615–620.
53.
HoffBH, FlemmingDC, SasseF.Use of positive airway pressure without endotracheal intubation. Crit Care Med1979;7:559–562.
SmithRA, KirbyRR, GoodingDO, CivettaJM. Continuous positive airway pressure (CPAP) by face mask. Crit Care Med1980;8:483–485.
56.
CarlssonC, SondénB, ThylénU.Can postoperative continuous positive airway pressure (CPAP) prevent pulmonary complications after abdominal surgery?Intensive Care Med1981;7:225–229.
57.
BaggerM.A simple and inexpensive device for administration of continuous positive airway pressure breathing. Br J Anaesth1980;52:627–628.
58.
SullivanCE, Berthon-JonesM, IssaFG, EvesL.Reversal of obstructive sleep apnea by continuous positive airway pressure applied through the nares. Lancet1981;1:862–865.
59.
KlopfensteinCE, ForsterA, SuterPM. Pneumocephalus, a complication of continuous positive airway pressure after trauma. Chest1980;78:656–657.
SturgeonCLJr, DouglasME, DownsJB, DannemillerFJ. PEEP and CPAP: Cardiopulmonary effects during spontaneous ventilation. Anesth Analg (Cleve)1977;56:633–639.
66.
DouglasME, DownsJB. Cardiopulmonary effects of PEEP and CPAP (letter). Anesth Analg (Cleve)1978;57:347–350.
67.
FieldsA, SterlingD.Patient work in open-system IMV (letter). Respir Care1978;23:1136.
68.
GheriniS, PetesRM, VirgilioRW. Mechanical work on the lungs and work of breathing with positive end-expiratory pressure and continuous positive airway pressure. Chest1979;76:251–256.