Abstract
Background:
Pressurized metered-dose inhalers (pMDIs) rely on hydrofluoroalkane (HFA) propellants that have a high global warming potential (GWP). Reformulation with next-generation, low-GWP propellants, such as HFA-152a, offers a strategy to reduce climate impact; however, changes in propellant composition can affect aerosol characteristics and potentially alter lung deposition, requiring robust demonstration of therapeutic equivalence.
Methods:
Functional respiratory imaging, combining high-resolution computed tomography and computational fluid dynamics, was used to compare the lung deposition of a fixed triple combination of beclometasone dipropionate, formoterol fumarate, and glycopyrronium bromide (BDP/FF/GB) delivered via a pMDI formulated with either HFA-134a (Reference) or HFA-152a (Test). Ten patients with chronic obstructive pulmonary disease (GOLD stages 2–4) were retrospectively selected. Patient-specific airway geometries, a standardized inhalation profile, and formulation-specific particle size distributions and plume characteristics were applied. Deposition was quantified in the intrathoracic, central + distal, and peripheral lung regions, and the (central + distal)/peripheral ([C + D]/P) deposition ratio was evaluated.
Results:
Mean intrathoracic deposition was comparable between the Reference and Test formulations, ranging from 45.95% to 46.88% of the delivered dose (DD). Deposition in the central + distal airways accounted for 12% of DD for both formulations, whereas peripheral deposition predominated, with 33.7% of DD for the Test formulation and 34.5% of DD for the Reference formulation. The (C + D)/P ratios were similar across all active components (0.35–0.37), indicating consistent preferential deposition in the peripheral/small airways. Although inter-patient variability was observed, intra-subject comparisons showed close agreement between propellants.
Conclusion:
Reformulation of the BDP/FF/GB pMDI with the low-GWP propellant HFA-152a preserved total and regional lung deposition characteristics relative to the current HFA-134a formulation. These findings support the maintenance of deposition performance while enabling a substantial reduction in environmental impact, reinforcing the potential of HFA-152a as a next-generation propellant for carbon minimal pMDI therapies.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.