Abstract
Background
Previous research indicates low disposal rates of excess postoperative narcotics, leaving them available for diversion or abuse. This study examined the effect of introducing a portable disposal device on excess opiate opioid disposal rates after lower extremity orthopaedic surgery.
Methods
This was a single site randomized control trial within an outpatient orthopaedic clinic. All patients 18 years or older, undergoing outpatient foot and ankle surgery between December 1, 2017 and August 1, 2018 were eligible. Patients were prospectively enrolled and randomized to receive standard opioid disposal instructions or a drug deactivation device at 2-week postoperative appointments. Participants completed an anonymous survey at 6-week postoperative appointments.
Results
Of the 75 patients surveyed, 68% (n = 26) of the experimental group and 56% (n = 21) of the control group had unused opioid medication. Of these, 84.6% of patients who were given Deterra Drug Deactivation System deactivation pouches safely disposed of excess medication, compared with 38% of controls (
Conclusions
Providing a portable disposal device with postoperative narcotic prescriptions may increase safe disposal rates of excess opioid medication following lower extremity orthopaedic surgery.
Levels of Evidence
Level I
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.