DemongeotJVironeGDuchêneFBenchetritGHervéTNouryNRialleV. Multi-sensors acquisition, data fusion, knowledge mining and alarm triggering in health smart homes for elderly people. C R Biol.2002;325 (6): 673–82.
2.
De SilvaCW. The role of soft computing in intelligent machines. Philos Transact A Math Phys Eng Sci.2003;361 (1809): 1749–80.
3.
MahmoudiBSanchezJC. A symbiotic brain-machine interface through value-based decision making. PLoS One.2011;6 (3): e14760.
AllenM. Pacemakers and implantable cardioverter defibrillators. Anaesthesia.2006;61 (9): 883–90.
6.
BogertLWErol-YilmazATukkieRVan LieshoutJJ. Varying the heart rate response to dynamic exercise in pacemaker-dependent subjects: Effects on cardiac output and cerebral blood velocity. Clin Sci (Lond).2005;109 (6): 493–501.
7.
GrecoEMFerrarioMRomanoS. Clinical evaluation of peak endocardial acceleration as a sensor for rate responsive pacing. Pacing Clin Electrophysiol.2003;26 (4 Pt 1): 812–8.
8.
DragoFSilvettiMSDe SantisAFazioGBiancalanaGGrutterGRinelliG. Closed loop stimulation improves ejection fraction in pediatric patients with pacemaker and ventricular dysfunction. Pacing Clin Electrophysiol.2007;30 (1): 33–7.
9.
GroeneveldPWFarmerSASuhJJMattaMAYangF. Outcomes and costs of implantable cardioverter-defibrillators for primary prevention of sudden cardiac death among the elderly. Heart Rhythm.2008;5 (5): 646–53.
10.
WathenM. Implantable cardioverter defibrillator shock reduction using new antitachycardia pacing therapies. Am Heart J.2007;153 (4 Suppl): 44–52.
11.
TehraniFTRoumJH. Flex: A new computerized system for mechanical ventilation. J Clin Monit Comput.2008;22 (2): 121–30.
12.
TehraniFTAbbasiS. Evaluation of a computerized system for mechanical ventilation of infants. J Clin Monit Comput.2009;23 (2): 93–104.
13.
ChatburnRLMireles-CabodevilaE. Closed-loop control of mechanical ventilation: Description and classification of targeting schemes. Respir Care.2011;56 (1): 85–102.
14.
LiuNChazotTHamadaSLandaisABoichutNDussaussoyCTrillatBBeydonLSamainESesslerDIFischlerM. Closed-loop coadministration of propofol and remifentanil guided by bispectral index: A randomized multicenter study. Anesth Analg.2011;112 (3): 546–57.
VargoJJCohenLBRexDKKwoPY. Position statement: Non-anesthesiologist administration of propofol for GI endoscopy. Gastrointest Endosc.2009;70 (6): 1053–9.
17.
MaurerWGPhilipBK. Propofol infusion platforms: Opportunities and challenges. Digestion.2010;82 (2): 127–9.
18.
PambiancoDJVargoJJPruittREHardiRMartinJF. Computer-assisted personalized sedation for upper endoscopy and colonoscopy: A comparative, multicenter randomized study. Gastrointest Endosc.2011;73 (4): 765–72.
KlonoffDC. The artificial pancreas: How sweet engineering will solve bitter problems. J Diabetes Sci Technol.2007;1 (1): 72–81.
21.
CunhaJAHsuICPouliotJRoachMIIIShinoharaKKurhanewiczJReedGStoianoviciD. Toward adaptive stereotactic robotic brachytherapy for prostate cancer: Demonstration of an adaptive workflow incorporating inverse planning and an MR stealth robot. Minim Invasive Ther Allied Technol.2010;19 (4): 189–202.
22.
KlonoffDCZimlikiCLStevensABeastonPPinkosAChoeSYArreaza-RubínGHeetderksW. Public Workshop—Innovations in Technology for the Treatment of Diabetes: Clinical Development of the artificial Pancreas (an Autonomous System). J Diabetes Sci Technol.2011;5 (3): 804–26.
23.
HakenbergOW. Brachytherapy for prostate cancer in 2010. Panminerva Med.2010;52 (3): 183–8.
24.
KeeWD NganTamYHKhawKSNgFFCritchleyLAKarmakarMK. Closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: A preliminary descriptive study. Anaesthesia.2007;62 (12): 1251–6.
25.
YingH. Theory and application of a novel fuzzy PID controller using a simplified Takagi-Sugeno rule scheme. Inf Sci.2000;123 (3–4): 281–93.
26.
LuginbühlMBieniokCLeibundgutDWymannRGentiliniASchniderTW. Closed-loop control of mean arterial blood pressure during surgery with alfentanil: Clinical evaluation of a novel model-based predictive controller. Anesthesiology.2006;105 (3): 462–70.
27.
KramerGCKinskyMPProughDSSalinasJSondeenJLHazel-ScerboMLMitchellCE. Closed-loop control of fluid therapy for treatment of hypovolemia. J Trauma.2008;64 (4 Suppl): S333–41.