BarrettJFKeatN.Artifacts in CT: recognition and avoidance. RadioGraphics. 2004,
24: 1679–91.
2.
BetteSJBraunFMHaertingM, et al.
Visualization of bone details in a novel photon-counting dual-source CT scanner-comparison with energy-integrating CT. Eur Radiol. 2022,
32: 2930–6.
3.
BooijRBuddeRPJDijkshoornMLvan StratenM.Technological developments of X-ray computed tomography over half a century: user's influence on protocol optimization. Eur J Radiol. 2020,
131: 109261.
EtliIKozaciNAvciMKarakoyunOF.Comparison of the diagnostic accuracy of X-ray and computed tomography in patients with wrist injury. Injury. 2020,
51: 651–5.
FlohrTGStierstorferKSüssCSchmidtBPrimakANMcColloughCH.Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT. Med Phys. 2007,
34: 1712–23.
8.
Gondim TeixeiraPAVillaniNAit IdirM, et al.
Ultra-high resolution computed tomography of joints: practical recommendations for acquisition protocol optimization. Quantitative Imaging Med Surg. 2021,
11: 4287–98.
9.
KämmerlingNSandstedtMFarneboSPerssonATesselaarE.Assessment of image quality in photon-counting detector computed tomography of the wrist – an ex vivo study. Eur J Radiol. 2022,
154: 110442.
10.
KlintströmBHenrikssonLMorenoR, et al.
Photon-counting detector CT and energy-integrating detector CT for trabecular bone microstructure analysis of cubic specimens from human radius. Eur Radiol Exp. 2022,
6: 31.
11.
LauLCMLeeWYWButlerAPH, et al.
Multi-energy spectral photon-counting computed tomography (MARS) for detection of arthroplasty implant failure. Sci Reports. 2021,
11: 1554.
12.
MalleeWDoornbergJNRingDvan DijkCNMaasMGoslingsJC.Comparison of CT and MRI for diagnosis of suspected scaphoid fractures. J Bone Joint Surg Am. 2011,
93: 20–8.
MüllerFCGosvigKKBørgesenH, et al.
Dual-energy CT for suspected radiographically negative wrist fractures: a prospective diagnostic test accuracy study. Radiology. 2020,
296: 596–602.
15.
NuchternJVHartelMJHenesFO, et al.
Significance of clinical examination, CT and MRI scan in the diagnosis of posterior pelvic ring fractures. Injury. 2015,
46: 315–9.
16.
RajendranKPetersilkaMHenningA, et al.
First clinical photon-counting detector CT system: technical evaluation. Radiology. 2021, 303: 130–8.
17.
RajendranKVossBAZhouW, et al.
Dose reduction for sinus and temporal bone imaging using photon-counting detector CT with an additional tin filter. Investigative Radiol. 2020,
55: 91–100.
WellingRDJacobsonJAJamadarDAChongSCaoiliEMJebsonPJL.MDCT and radiography of wrist fractures: radiographic sensitivity and fracture patterns. Am J Roentgenol. 2008,
190: 10–6.