Abstract
We evaluated the tendon length and excursion after extensor tendon grafting following ruptures at the distal radioulnar joint in eight patients. The mean patient age was 70.8 years (range 58 to 84), and the mean follow-up period was 63 months (range 12 to 129). Radiographic markers were placed on ends of the grafted tendon to assess changes in length and passive excursion. The mean length of the grafted tendon and mean passive excursion were 68.2 mm and 4.4 mm immediately after tendon grafting, 76.1 mm and 7.1 mm at 1 year postoperatively, and 76.3 mm and 7.3 mm at final follow-up, respectively. The mean elongation of the grafted tendon was 12% and mean increase of excursion was 2.9 mm. We recommend that tension set during extensor tendon grafting should be with the metacarpophalangeal joint of the affected finger in a slightly extended position as compared with adjacent fingers.
Level of evidence
IV
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.