Abstract
The ultimate tensile repair strength and gap formation of the pig extensor tendons repaired with a standard 4-strand Savage with epitendinous suture repair, was compared with a new technique of adding a vein sleeve. Force and displacement data were recorded, and video images during linear cyclic loading up to failure. At 35 N, video-graphic observation detected significantly smaller gap lengths in the standard and vein repair specimens compared with standard repair specimens (p = 0.047). The incidence of 3 mm gaps between the repaired tendon ends in the standard repair group was 20 %, but no 3 mm gaps were seen in the standard and vein specimens. The addition of a vein sleeve increased the ultimate tensile strength of the standard repair from 50.4 N (4.5) to 55.4 N (4.5); this was statistically significant (p = 0.03). This study demonstrated that the addition of a vein graft prevented gap formation and increased ultimate tensile strength of tendon repair.
Get full access to this article