Abstract
Background
Current imaging modalities underestimate the severity of intracranial atherosclerotic disease (ICAD). High resolution vessel wall imaging (HR-VWI) MRI is a powerful tool in characterizing plaques. We aim to show that HR-VWI MRI is more accurate at detecting and characterizing intracranial plaques compared to digital subtraction angiography (DSA), time-of-flight (TOF) MRA, and computed tomography angiogram (CTA).
Methods
Patients with symptomatic ICAD prospectively underwent 7T HR-VWI. We calculated: degree of stenosis, plaque burden (PB), and remodeling index (RI). The sensitivity of detecting a culprit plaque for each modality as well as the correlations between different variables were analyzed. Interobserver agreement on the determination of a culprit plaque on every imaging modality was evaluated.
Results
A total of 44 patients underwent HR-VWI. Thirty-four patients had CTA, 18 TOF-MRA, and 18 DSA. The sensitivity of plaque detection was 88% for DSA, 78% for TOF-MRA, and 76% for CTA. There's significant positive correlation between PB and degree of stenosis on HR-VWI MRI (p < 0.001), but not between PB and degree of stenosis in DSA (p = 0.168), TOF-MRA (p = 0.144), and CTA (p = 0.253). RI had a significant negative correlation with degree of stenosis on HR-VWI MRI (p = 0.003), but not on DSA (p = 0.783), TOF-MRA (p = 0.405), or CTA (p = 0.751). The best inter-rater agreement for culprit plaque detection was with HR-VWI (p = 0.001).
Conclusions
The degree of stenosis measured by intra-luminal techniques does not fully reflect the true extent of ICAD. HR-VWI is a more accurate tool in characterizing atherosclerotic plaques and may be the default imaging modality in clinical practice.
Keywords
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.