Stenting as adjuvant therapy for the coiling of acutely ruptured aneurysms remains controversial due to the necessity of anticoagulation and antiplatelet medications. We report our experience using the Neuroform stent in the management of 41 aneurysms in 40 patients over a period of three years. For aneurysms whose open surgical risk remains excessive with a morphology that would preclude complete embolization, the risks of stenting may be warranted.
FiorellaDAlbuquerqueFC: Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: Results at initial (3–6-mo) follow-up. Neurosurgery56(6): 1191–1201; discussion 201–202, 2005.
2.
AkpekSAratA: Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: A single-center experience. Am J Neuroradiol26(5): 1223–1231, 2005.
3.
KatsaridisVPapagiannakiCViolarisC: Embolization of acutely ruptured and unruptured wide-necked cerebral aneurysms using the neuroform2 stent without pretreatment with antiplatelets: A single center experience. Am J Neuroradiol27(5): 1123–1128, 2006.
dos Santos SouzaMPAgidR: Microstent-assist-ed coiling for wide-necked intracranial aneurysms. Can J Neurol Sci32(1): 71–81, 2005.
6.
YahiaAMGordonV: Complications of Neuroform stent in endovascular treatment of intracranial aneurysms. Neurocrit Care8(1): 19–30, 2008.
7.
BiondiAJanardhanV: Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: Strategies in stent deployment and midterm follow-up. Neurosurgery61(3): 460–468; discussion 8–9, 2007.
8.
BenitezRPSilvaMT: Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neurosurgery54(6): 1359–1367; discussion 68, 2004.
9.
LylykPFerrarioA: Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms. J Neurosurg102(2): 235–241, 2005.
HenkesHBAFelberS: Endovascular Coil Occlusion of Intracranial Aneurysms Assisted by a Novel Self-Expandable Nitinol Microstent (Neuroform). Interventional Neuroradiology8: 107–119, 2002.
12.
HowingtonJUHanelRA: The Neuroform stent, the first microcatheter-delivered stent for use in the intracranial circulation. Neurosurgery54(1): 2–5, 2004.
13.
CloftHJKallmesDF: Cerebral aneurysm perforations complicating therapy with Guglielmi detachable coils: A meta-analysis. Am J Neuroradiol23(10): 1706–1709, 2002.
14.
NgPKhangureMS: Endovascular treatment of intracranial aneurysms with Guglielmi detachable coils: Analysis of midterm angiographic and clinical outcomes. Stroke33(1): 210–217, 2002.
15.
RossIBDhillonGS: Complications of endovascular treatment of cerebral aneurysms. Surg Neurol64(1): 12–18; discussion 8–9, 2005.
16.
ParkHKHorowitzM: Periprocedural morbidity and mortality associated with endovascular treatment of intracranial aneurysms. Am J Neuroradiol26(3): 506–514, 2005.
17.
van RooijWJSluzewskiM: Procedural complications of coiling of ruptured intracranial aneurysms: Incidence and risk factors in a consecutive series of 681 patients. Am J Neuroradiol27(7): 1498–1501, 2006.
18.
HenkesHFischerS: Endovascular coil occlusion of 1811 intracranial aneurysms: Early angiographic and clinical results. Neurosurgery54(2): 268–280; discussion 80–85, 2004.
19.
FriedmanJANicholsDA: Guglielmi detachable coil treatment of ruptured saccular cerebral aneurysms: Retrospective review of a 10-year single-center experience. Am J Neuroradiol24(3): 526–533, 2003.
20.
GallasSPascoA: A multicenter study of 705 ruptured intracranial aneurysms treated with Guglielmi detachable coils. Am J Neuroradiol26(7): 1723–1731, 2005.
21.
VinuelaFDuckwilerGMawadM: Guglielmi detachable coil embolization of acute intracranial aneurysm: Perioperative anatomical and clinical outcome in 403 patients. J Neurosurg86(3): 475–482, 1997.
22.
TummalaRPChuRM: Outcomes after aneurysm rupture during endovascular coil embolization. Neurosurgery49(5): 1059–1066; discussion 66–67, 2001.
23.
RicolfiFLe GuerinelC: Rupture during treatment of recently ruptured aneurysms with Guglielmi electrodetachable coils. Am J Neuroradiol19(9): 1653–1658, 1998.
24.
SluzewskiMBoschJA: Rupture of intracranial aneurysms during treatment with Guglielmi detachable coils: Incidence, outcome, and risk factors. J Neurosurg94(2): 238–240, 2001.
25.
WinnHRRichardsonAEJaneJA: The long-term prognosis in untreated cerebral aneurysms: I. The incidence of late hemorrhage in cerebral aneurysm: A 10-year evaluation of 364 patients. Ann Neurol1(4): 358–370, 1977.
26.
KassellNFDrakeCG: Review of the management of saccular aneurysms. Neurol Clin1(1): 73–86, 1983.
27.
JaneJAWinnHRRichardsonAE: The natural history of intracranial aneurysms: Rebleeding rates during the acute and long term period and implication for surgical management. Clin Neurosurg24: 176–184, 1977.
28.
KisBWeberW: Elective treatment of saccular and broad-necked intracranial aneurysms using a closed-cell nitinol stent (Leo). Neurosurgery58(3): 443–450; discussion −50, 2006.
29.
WeberWBendszusM: A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: Initial clinical and angiographic results in 31 aneurysms. Neuroradiology49(7): 555–561, 2007.
30.
YavuzKGeyikS: Immediate and midterm follow-up results of using an electrodetachable, fully retrievable SOLO stent system in the endovascular coil occlusion of wide-necked cerebral aneurysms. J Neurosurg107(1): 49–55, 2007.
31.
HohBLNogueiraRG: Safety of heparinization for cerebral aneurysm coiling soon after external ventriculostomy drain placement. Neurosurgery57(5): 845–849; discussion −9, 2005.
32.
ManikerAHVaynmanAY: Hemorrhagic complications of external ventricular drainage. Neurosurgery59(4Sup2): ONS 419–424; discussion ONS 24–25, 2006.
33.
RossIBDhillonGS: Ventriculostomy-related cerebral hemorrhages after endovascular aneurysm treatment. Am J Neuroradiol24(8): 1528–1531, 2003.
34.
WiesmannMMayerTE: Intracranial bleeding rates associated with two methods of external ventricular drainage. J Clin Neurosci8(2): 126–128, 2001.
35.
The CARAT Investigators: Rates of delayed rebleeding from intracranial aneurysms are low after surgical and endovascular treatment. Stroke37(6): 1437–1442, 2006.
36.
JohnstonSCDowdCF: Predictors of rehemorrhage after treatment of ruptured intracranial aneurysms: The Cerebral Aneurysm Rerupture After Treatment (CARAT) study. Stroke39(1): 120–125, 2008.
37.
MolyneuxAKerrR: International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: A randomised trial. Lancet360(9342): 1267–1274. 2002.
38.
MolyneuxAJKerrRS: International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: A randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion. Lancet366(9488): 809–817, 2005.
39.
SluzewskiMvan RooijWJ: Late rebleeding of ruptured intracranial aneurysms treated with detachable coils. Am J Neuroradiol26(10): 2542–2549, 2005.
40.
WhitePMLewisSC: HydroCoil Endovascular Aneurysm Occlusion and Packing Study (HELPS Trial): Procedural Safety and Operator-Assessed Efficacy Results. Am J Neuroradiol29(2): 217–223, 2008.