Abstract
Background:
Metacarpal fractures are common injuries with multiple options for fixation. Our purpose was to compare outcomes in metacarpal fractures treated with intramedullary screw fixation (IMF), Kirschner wires (K-wires), or plating.
Methods:
A systematic literature review using the MEDLINE database was performed for studies investigating metacarpal fractures treated with IMF, plating, or K-wires. We identified 34 studies (9 IMF, 8 plating, 17 K-wires). A meta-analysis using both mixed and fixed effects models was performed. Outcome measures included mean Disabilities of the Arm, Shoulder, and Hand (DASH) scores, total active motion (TAM), grip strength, time to radiographic healing, and rates of infection and reoperation.
Results:
Patients with IMF had significantly lower DASH scores (0.6 [95% confidence interval [CI], 0.2-1.0]) compared with K-wires (7.4 [4.8-9.9]) and plating (9.8 [5.3-14.3]). Intramedullary screw fixation also had significantly lower rates of reoperation (4%, [2%-7%]), compared with K-wires (11% [7%-16%]) and plating (11% [0.07-0.17]). Grip strength was significantly higher in IMF (104.4% [97.0-111.8]) compared with K-wires (88.5%, [88.3-88.7]) and plating (90.3%, [85.4-95.2]). Mean odds ratio time was similar between IMF (21.0 minutes [10.4-31.6]) and K-wires (20.8 minutes [14.0-27.6]), but both were shorter compared with plating (52.6 minutes [33.1-72.1]). There were no statistically significant differences in time to radiographic healing, TAM, or rates of reoperation or infection.
Conclusions:
This meta-analysis compared the outcomes of metacarpal fixation with IMF, K-wires, or plating. Intramedullary screw fixation provided statistically significant lower DASH scores, higher grip strength, and lower rates of reoperation, suggesting that it is a comparable method of fixation to K-wires and plating for metacarpal fractures.
Keywords
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.
