Abstract
Objective
Plication of the diaphragm is a life-changing procedure for patients affected by diaphragm paralysis. Traditionally, this procedure is performed through a thoracotomy. Access to the diaphragm via this incision is poor and the indications for surgery are limited to patients who can actually sustain such an invasive approach and associated morbidities. A minimally invasive approach was developed to improve the surgical management of diaphragm paralysis.
Methods
Patients underwent minimally invasive diaphragm plication either by video-assisted or robotic surgery through a 3-port technique with CO2 insufflation. Patients were followed at the routine 6-week clinic and also by telephone consultation 6 to 12 months postoperatively. Data were collected on postoperative complications, postoperative pain or numbness, symptomatic improvement, and change to quality of life following surgery.
Results
Forty-eight patients underwent 49 minimally invasive diaphragm plication. Median postoperative length of hospital stay was 4 days (range: 2 to 34 days) and there were no cases of mortality. Mean reduction in Medical Research Council dyspnea score per patient was 2.2 points (mode: 3 points). Twenty-eight patients (77.8%) reported a significant symptomatic improvement enabling improvements in quality of life, and 97.2% (n = 35) were satisfied with the surgical outcome.
Conclusions
Minimally invasive diaphragm plication is a safe procedure associated with prompt postoperative recovery. It is effective at reducing debilitating dyspnea and improving quality of life.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.