Abstract
Objective
“No-touch” (NT) saphenous vein harvesting preserves the adventitial vasa vasorum, prevents medial ischemia, and is associated with an improved short-term and long-term vein graft patency. It may also be associated with a higher rate of harvest site complications. Endovascular vein harvesting (endo-vein) has a low rate of harvest site complications but also a tendency toward a lower patency rate.
Methods
During a 2-year period (2011–2012), we compared the vein graft patency at symptom-directed cardiac catheterization as well as wound complication rates in 210 patients who received either NT (87 patients) or endo-vein (123 patients).
Results
The recatheterization rate for the two groups was similar: 9 (10.3%) of 87 of the NT patients versus 11 (9.0%) of 123 of the endo-vein patients. There was a significant difference in vein graft patency between the groups: 15 (94%) of 16 NT vein grafts were patent versus 6 (27%) of 22 of endo-veins (
Conclusions
These results suggest that NT vein harvesting may be associated with improved graft patency, but methods should be developed to lower wound complication rates.